Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Bai-Hu-Jia-Ren-Shen-Tang Decoction (BHJRSTD) is one of the oldest classic Chinese medicine prescriptions which used in the field of treatment of diabetes. However, to the best of our knowledge, the ingredients of this prescription have not been identified, and there are very few studies on the anti-diabetic mechanism of this prescription. Therefore, BHJRSTD was detected and identified by ultra-high-performance liquid chromatography coupled with Quadrupole-Exactive Focus Orbitrap MS (UHPLC–Q/Orbitrap/MS/MS). We identified 74 compounds, including flavonoids, alkaloids, chalcones, xanthones, phenols, phenylpropanoids, terpenes, triterpenes, amino acid derivatives, etc. Then, Sprague Dawley rats were fed with a high-fat and high-sugar diet for two months and injected with streptozotocin (STZ) to induce type 2 diabetes (T2DM). The diabetic rats were randomized to given metformin (200 mg kg⁻¹•d⁻¹, n = 15), BHJRSTD extracts (40 g kg⁻¹•d⁻¹) and BHJRSTD extracts (10 g kg⁻¹•d⁻¹) by gavage for 8 weeks. The results confirmed that BHJRSTD significantly decreased the level of MDA and increased levels of catalase (CAT), superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px), it shows that the prescription has significant antioxidant activity in the treatment of T2DM.
EN
A sensitive and accurate LC-MS/MS method was developed and validated for the simultaneous quantification of rivaroxaban (RIV) and sitagliptin (SIT) in rat plasma using apixaban as internal standard (IS). An Agilent Eclipse plus C18 column (2.1 × 100 mm, 3.5 µm, Agilent) was used for chromatographic separation with isocratic elution. Multiple reaction monitoring (MRM) using positive-ion ESI mode to monitor ion transitions of m/z 436.8→144.9 for RIV, m/z 407.7→173.8 for SIT, m/z 459.8→442.8 for IS. The procedure of method validation included selectivity, linearity, precision, accuracy, matrix effect, extraction recovery and stability were conducted according to the guidelines of EMA and FDA. The results indicated that no obvious drug-drug interactions occurred might be owing to their differences in metabolic pathways.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.