The touch trigger probe plays an important role in modern metrology because of its robust and compact design with crash protection, long life and excellent repeatability. Aside from coordinate measuring machines (CMM), touch trigger probes are used for workpiece location on a machine tool and for the accuracy assessment of the machine tools. As a result, the accuracy of the measurement is a matter of interest to the users. The touch trigger probe itself as well as the measuring surface, the machine tool, measuring environment etc. contribute to measurement inaccuracies. The paper presents the effect of surface irregularities, surface wetness due to cutting fluid and probing direction on probing accuracy on a machine tool.
PL
Elektrostykowe sondy przełączające grają istotną rolę we współczesnej metrologii z uwagi na ich zwartą i silną konstrukcję, odporność na uszkodzenia, długowieczność i doskonałą powtarzalność. Obok zastosowań we współrzędnościowych maszynach pomiarowych (CMM), sondy te są wykorzystywane do wyznaczenia położenia przedmiotu obrabianego na obrabiarce i oceny dokładności obrabiarek. Tak więc, dokładność pomiaru jest sprawą istotną dla użytkowników. Do powstawania niedokładności pomiaru przyczynia się sama sonda, a także powierzchnia pomiarowa, obrabiarka, środowisko pomiarowe itp. W artykule przedstawiono wpływ nierówności powierzchni, wilgotności powierzchni powodowanej obecnością chłodziwa i kierunku sondowania na dokładność pomiaru na obrabiarce.
2
Content available remote Metoda korekcji promienia końcówki w pomiarach skaningowych WMP
PL
Przedstawiono nowy algorytm wyznaczania punktów skorygowanych w pomiarach skaningowych WMP, różniący się tym od pozostałych, że nie jest obliczany wektor korekcji, lecz bezpośrednio wyznaczane jest najbardziej wiarygodne położenie punktu pomiarowego skorygowanego.
EN
The paper presents the operating principle of a new algorithm for probe tip radius correction in scanning measurements of freeform 2D contours carried out on coordinate measuring machines. It does not require obtaining the normal vector traditionally used for probe tip correction, but the most likely contact point.
EN
Users of coordinate measuring machine and large gantry machines need to ensure the volumetric performance of their machines in order to inspect, or machine, mechanical parts with precision. In the case of CMMs, the ASME B89.4.10360.2-2008 document imposes seven directions for a volumetric check. These directions offer some redundancy for axis location (out-of-squarenesses) and scale factor estimation. The paper looks at the opportunity of using the data for immediate machine correction and the risks involved. In particular, the fact of using test data for calibration and verification, the potential contamination from non-modelled motion errors and the representativity of the estimated parameters are considered. Experimental results obtained using laser interferometry on a LEGEX CMMs are used to present the main concepts.