A developed three stage method for determination the windings impedance of measuring transformer are shown in this paper. During the measurement process, there is no need to use the standard voltage divider instead, a voltage divider having the constant, unknown error is used. This ratio error is eliminated during measuring procedure. In this paper, the obtained measurement results of the winding impedance and uncertainty budged are presented.
The paper presents a fast-reversed DC voltage/current source (FRDC) used for determination of the frequency-independent AC-DC transfer difference of thermal voltage converters. It contains also results of experiments and measurements.
The paper presents results of investigations of the two precise voltage followers (buffers) intended for the use in precision impedance metrology. The main application of these buffers are buffering the outputs of multi-phase digital sources of sinusoidal voltage used in precise impedance measurements.
Odtwarzanie jednostek miar oraz przechowywanie i wykorzystywanie ich wzorców pierwotnych musi odbywać się w odpowiednich warunkach środowiskowych. W pracy przedstawiono opis systemu stabilizującego warunki środowiskowe w Laboratorium Wzorców AC-DC Instytutu Metrologii, Elektroniki i Automatyki Politechniki Śląskiej. W artykule zamieszczono również wyniki badań systemu oraz zaproponowano metody jego udoskonalenia.
EN
Primary standards of physical quantities are the basis of traceability and uniformity of all measurements. Appropriate environmental conditions should be provided to maintain the standards and reproduce unit of measures. In the paper there are described the resources used for stabilization of temperature and humidity in the Laboratory of AC-DC Standards. The results of investigations of environmental parameters and possibilities for their further improvement are presented. A view of the interior of the electromagnetically shielded chamber and of the measuring station in the chamber of the Laboratory of AC-DC Standards are shown in Figs. 1 and 2, respectively. A measuring system consisting of an air handling unit suspended over the chamber and other devices cooperated with it (Fig. 3) ensures temperature and humidity stabilization inside the chamber. An air conditioning system based on the chilled water enables setting temperature in the range from 20 to 25°C. In order to confirm the assumed temperature stability (maximum ±0,2 K per hour), suitable measurements were taken with use of a thermohygrometer Label LB706B. The results of short and long-term stability of the temperature at the measuring station are shown in Figs. 4 and 5, respectively. Based on the presented results, it can e concluded that the system presented in the paper meets the assumed environmental requirements and enables realization of an AC-DC transfer with type A uncertainty at the level of V/V.
Publikacja przedstawia opracowany system mikroprocesorowy, służący do pomiaru zależności efektywnego czasu transmisji od odległości pomiędzy urządzeniami w sieci ZigBee, wyniki uzyskanych pomiarów oraz nowatorski sposób opisu opóźnień komunikacyjnych w sieci bezprzewodowej za pomocą modelu probabilistycznego. Opracowany system pozwala również na badanie innych parametrów transmisyjnych. Jego głównym zadaniem jest pomiar czasu pomiędzy wysłaniem pakietu danych, a informacją z modułu odbiorczego potwierdzającą odbiór.
EN
This paper presents a microprocessor system for measuring the influence of a distance between ZigBee network devices on the effective transmission time. The system was developed by the authors. The measurement results obtained are given. A new way of communication delays in a wireless network is described. The developed system allows studying the effects of various obstacles in the transmission, in particular the impact of suppression of free space. The measuring system consists of a microcontroller to supervise the broadcasting and receiving data. Its main task is to measure the time between sending a data packet and receiving information from the module confirming receipt. The measurement result is stored in a file in real time. The system is easy to use. The XBee ZigBee and XBee-Pro modules by Digi International were used for taking measurements. They provide live coverage of two or more elements of the final network, allowing for the construction of wide area networks based on star and mesh configuration. A new probabilistic model was used to describe the delay. It allows you also to save the delay as well as the relative number of packets received during each transmission and retransmission of the data. The model is simple to implement in simulation programs. The data obtained from measurements show that increase in the distance between the modules has an impact on the number of retransmission and lost data packets. This enables designating certain guidelines to aid the design of a wireless network.
W pracy przestawiono koncepcję i podstawowe właściwości modulatora szerokości impulsu (PWM), w którym zastosowano dodatkową modulację amplitudy fragmentu przebiegu o szerokości równej jednemu okresowi przebiegu taktującego. Celem tej modyfikacji jest zwiększenie rozdzielczości nastawy wartości współczynnika wypełnienia modulatora, pełniącego rolę przetwornika cyfowo-analogowego w wielomiarowym źródle wzorcowego napięcia stałego.
EN
The paper presents the idea and basic properties of a pulse-width modulator (PWM) with additional amplitude modulation of the part of the signal. The width of the amplitude-modulated part is equal to one clock period. The reason of this additional modulation is to increase the resolution of setting the duty cycle of the PWM signal. The modulator is used as a digital to analog converter in an adjustable source of standard dc voltage.
W pracy przeanalizowano wpływ czasów załączania i wyłączania układów przełączających modulatorów szerokości impulsu na napięcie wyjściowe wytwarzane przez wielomiarowe źródło wzorcowego napięcia stałego. Zaproponowano modyfikację układu umożliwiającą zmniejszenie tego wpływu.
EN
Analysis of the effect of turn-on and turn-off times of switches in the pulse-width modulators on the voltage generated by the source of a standard DC voltage is presented in the paper. A modification of the circuit leading to reduction of this effect is also proposed.
W artykule przedstawiono opis miernika napięcia powrotnego o oryginalnej konstrukcji obwodu wejściowego, zapewniającego skuteczną redukcję prądów upływu. Określono źródła możliwych błędów, a następnie przeprowadzono pomiary sprawdzające opisanego miernika z wykorzystaniem 4-elementowego modelu RC wzorca izolacji elektrycznej z uwzględnieniem zjawiska absorpcji elektrycznej.
EN
In this paper the description of return voltage meter with original construction of input circuit affirmer and the effective reduction of loss currents are presented. The sources of possible return voltage meter error and the estimation of these errors values are defined. Then the checking measurements of the described return voltage meter with the use of constructed 4-element electrical insulation RC based standard (with regards to absorption phenomenon) are conducted.
9
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono propozycję konstrukcji przetwornicy DC/DC, w której zamiast typowego, analogowego układu sterującego, zastosowano mikrokontroler, realizujący programowo algorytm regulacji napięcia wyjściowego. Opisano problemy konstrukcyjne, źródła błędów oraz najważniejsze właściwości nowej konstrukcji. Przedstawiono niektóre wyniki badań modelu fizycznego.
EN
The paper presents an example of construction of a DC/DC voltage converter which uses a microcontroller with software realization of the output voltage regulation, instead of a traditional, analog control unit. Construction problems, error sources and the most important features of the new DC/DC converter as well as some research results of its physical model are given.
W pracy przedstawiono koncepcję źródła wzorcowego napięcia stałego wykorzystującego zasadę cyfrowej bezpośredniej syntezy sygnału. Podstawowym powodem zastosowania układu DDS jest uproszczenie dzielnika rezystancyjnego, stosowanego we współczesnych programowanych źródłach wzorcowego napięcia stałego. Opracowane źródło umożliwia nastawę napięcia w zakresie 0... U REF z rozdzielczoscią względną 1.10 -8. Przeprowadzona została wstępna ocena niepewności nastawy napięcia wyjściowego.
EN
The concept of a new programmable standard DC voltage source is presented in the paper. The source uses the direct digital synthesis (DDS) principle to simplify the design of the analog part of the source. The output voltage of the source can be set with a resolution of 8 significant digits in the 0... U REF range. Three main sources of uncertainty of the output voltage are depicted and partially analyzed.
W artykule przedstawiono oryginalną konstrukcję miernika napięcia powrotnego, charakteryzującą się przede wszystkim skuteczną kompensacją upływności izolacyjnych oraz zastosowaniem mikroprocesorowego sterowania pomiarami i cyfrowej rejestracji wyników pomiarowych.
EN
The paper presents a new construction of a recovery voltage meter which ensures the exceptionally effective compensation of insulation leakage conductances. A microprocessor used in the meter controls measurements. The measurement results are digitally recorded.
W artykule przedstawiono zmienioną, udoskonaloną konstrukcję układu pomiarowego miernika napięcia powrotnego. Przedstawiono analizę najważniejszych właściwości metrologicznych oraz niektóre wyniki badań przeprowadzonych na modelu fizycznym.
EN
The paper presents an improved version of the construction of the recovery voltage meter measuring circuit. Analysis of the most important metrological properties of this meter as well as the results of nvestigations of the meter physical model are given in the paper.
Ponadto podstawowe informacje o warunkach powstawania i mierzenia napięć powrotnych w dielektrykach. Zaproponowano nową koncepcję wykonania układu do pomiaru napięć powrotnych. Przedstawiony układ pomiarowy charakteryzuje się małymi upływnościami oraz możliwością zastosowania końcowego bloku pomiaru napięcia o relatywnie małej rezystancji wejściowej. Przedstawiono wyniki badań doświadczalnych modelu fizycznego opracowanego układu pomiarowego.
EN
Basics information on condition of arising and measuring recovery voltages in dielectrics has been given in the paper. A new idea of the circuit for recovery voltages has been suggested. The presented measuring circuit has low leakage conductances and it makes possible to use the final voltage measurement unit with relatively small input resistance. Results of experimental investigations of thephysical model of the measuring circuit have been presented as well.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.