The article contains descriptive statistics on rainfall in an area of the southern part of the last ice age in Europe, and which now comprises the north-eastern part of the Poland. The study covers the period of 1981-2010. The sums of the annual and monthly precipitation were calculated, while years and months were evaluated in relation to the multi-annual and monthly averages. The frequency of daily precipitations was also determined. Values of SPI (Standarized Precipitation Index) were calculated together with the values of the Selianinov Index, which measures the environmental aspect of precipitation. The average annual rainfall showed a spatial heterogeneity in the region from 700.1 mm (Elblag in the north-west) to 555.3 mm (Mława) in the east and south-east. The greatest precipitation occurred in the last decade of the analysed period of thirty years. However, statistical analysis shows no significant trend change in precipitation during this period. The number of years with sums of precipitation below 75% of the normal turned out to be very small. In the annual cycle, summer precipitation prevailed. On a monthly basis, the averages sometimes exceeded the multiyear averages by as much as 200%, while extreme lows in monthly precipitation reached levels below 25% of the long-term averages. The calculated value of the SPI indicated that the most common drought conditions occurred in May and June; such droughts did not occur in April and July. The Selianinov Index indicates that the least favorable hydrothermal conditions occur in April and May, while the most favorable conditions occur in August and September.
PL
Cel: Przedstawienie wyników badań reakcji na ogień kabli elektrycznych według normy PN-EN 60332-1-2:2010, a także dodatkowych badań ponadnormatywnych. Badania miały na celu zbadanie wpływu takich parametrów jak: średnica zewnętrzna, liczbą żył, materiał, z którego wykonano żyły, a także zastosowanie drucianego ekranu na rozprzestrzenianie ognia przez kable elektryczne. Projekt i metody: Badania wykonano na stanowisku badawczym zgodnym z normą PN-EN 60332-1-2:2010. Jest to podstawowa norma do określenia klasy reakcji na ogień Eca oraz dodatkowa w przypadku określania klas B1ca, B2ca, Cca, Dca zgodnie z klasyfikacją przedstawioną w normie klasyfikacyjnej PN-EN 13501-6. Badań dokonano na grupie kabli elektrycznych o średnicach od 7 mm do 17,5 mm, różniących się liczbą żył, a także materiałem, z którego wykonano żyły oraz powłokę zewnętrzną. Część przewodów wyposażona była również w ekran z ocynkowanych drucików. Metodykę badań rozszerzono o pomiary temperatury żył, za pomocą dwóch termopar umieszczonych wewnątrz przewodu, na końcach próbki. Oprócz testów normatywnych przeprowadzono również badania dla dwu- i trzykrotnie zwiększonych czasów przyłożenia płomienia. Wyniki: Kable ekranowane rozprzestrzeniały ogień w znacznie większym stopniu niż ich nieekranowane odpowiedniki. W przypadku kabli ekranowanych maksymalny zasięg zwęglenia rośnie proporcjonalnie do grubości przewodu. Nie zaobserwowano znacznych różnic w rozprzestrzenianiu ognia pomiędzy kablami różniącymi się wyłącznie materiałem, z którego wykonano żyły. Największy wzrost temperatur zanotowano w przewodach o najmniejszej średnicy. Temperatury żył mierzone na końcu oddalonym o około 100 mm od miejsca przyłożenia palnika osiągnęły maksymalnie około 40°C przy normatywnym czasie przyłożenia płomienia oraz około 150°C przy trzykrotnie zwiększonej ekspozycji. Dla żadnego z badanych kabli nie zanotowano natomiast wzrostu temperatury żył w punkcie pomiarowym oddalonym o 500 mm od miejsca przyłożenia płomienia. Wnioski: Podstawowym czynnikiem wpływającym na rozprzestrzenianie ognia przez kabel elektryczny jest materiał, z którego wykonano izolację. W przypadku kabli ekranowanych rosnący zasięg zwęglenia wraz ze wzrostem średnicy spowodowany był większą ilością palnego tworzywa poddanego oddziaływaniu płomienia. Materiał, z którego wykonano żyły, nie ma większego wpływu na rozprzestrzenianie ognia. Dla kabli o przebadanych średnicach zewnętrznych normatywny czas przyłożenia płomienia – to jest 60 sekund, wydaje się być najbardziej optymalny. Przy wydłużonych czasach ekspozycji nie zanotowano zwiększenia zasięgu zniszczeń na próbce, natomiast odnotowano spadek precyzji metody.
EN
Purpose: Presentation of the results of experimental research on the reaction to fire of electric cables according to PN-EN 60332-1-2, as well as some additional tests. The aim of the study was to assess the influence of selected parameters, such as outer diameter, number of cores, the core material and the presence shielding on the fire spread through electric cables. Project and methods: The study was performed on a testing stand, compliant with PN-EN 60332-1-2. In accordance with the typology presented in the classification standard PN-EN 13501-6, it constitutes a basic document for determining the Eca class reaction to fire, and an additional one for B1ca, B2ca, Cca, Dca classes. The tests were carried out on a group of electric cables with diameter between 7 mm and 17.5 mm, differing from each other in the amount of cores, as well as, in the core and insulation’s materials. Some of the cables had a screen made of galvanized wires. Testing methodology was supplemented with veins temperature measurements, carried out with the use of two thermo-couples positioned at both ends of the sample. Next to the tests based on normative methods, the authors also carried out some tests involving doubled and tripled flame exposure time. Results: Shielded cables spread the fire in a much greater extent than their unscreened counterparts. Shielded cables’ maximum charring range increases proportionally to the wire’s thickness. There were no significant differences in the fire spread between the cables differing from each other in their core material. The highest temperature was recorded in case of the cables with the smallest diameter. Temperature measured at the end of the conductors located about 100 mm from the point of application of the burner reached its maximum of about 40°C during the normative flame application time, and about 150°C at a tripled application time. At the second measuring point, positioned about 500 mm from the flame application point, there were no temperature changes noticed, for none of the tested samples. Conclusions: The main factor influencing the fire spread through an electric cable is the material of its insulation. In case of shielded cables the growth of charring range, along with the increase of cable diameter was caused by the greater amount of combustible material subjected to flame influence. The material of conductor does not have a major impact on the fire spread. For cables within tested diameters normative flame application time (i.e. 60 seconds) seems to be the most optimal. With extended exposure times there has been no significant increase of damage range, while there was a noticeable decrease of precision of the method.
PL
W niniejszym artykule przedstawione zostały podstawowe informacje na temat klasyfikacji reakcji na ogień kabli elektrycznych oraz metody badawcze wykorzystywane do przeprowadzenia prawidłowego procesu klasyfikacyjnego. Opisane metody badawcze odpowiadają warunkom pierwszej fazy rozwoju pożaru do momentu ewentualnego rozgorzenia oraz symulują warunki rzeczywistego pożaru. Przedstawione zostały kryteria klasyfikacji wraz z dodatkową klasyfikacją ze względu na wydzielanie się dymu oraz kapiących kropli i/lub cząsteczek. Celem przedstawionych metod badawczych oraz uregulowań prawnych (w trakcie notyfikacji) jest zapewnienie jednolitego systemu klasyfikacji kabli elektrycznych na podstawie wyników badań doświadczalnych.
EN
This paper presents some basic information on the reaction to fire classification of electric cables and testing methods used to perform a proper classification process. These methods represent the conditions of first phase of fire development up to possible flashover and also simulate real fire conditions. It shows the classification criteria with additional classification due to the emission of smoke and dropping droplets and/or particles. The aim of such testing methods and regulations (under notification) is to provide an classification uniform system of electric cables based on experimental results.
5
Content available remote Charakterystyka warunków opadowych Pojezierza Suwalskiego w latach 1971-2000
EN
The aim of this thesis was to present the characteristic of precipitation conditions in Suwałki Lake District. Analysis was made on the base of daily sum of precipitation of six meteorological stations during 1971-2000 period. Frequency of months and seasons with defi cit or excess of precipitation according to Kaczorowska’s criterion, frequency of non-precipitation day sequences >10, >15 and 20 days in the periods April-May, June-July, August-September and April–September were taken into consideration. Numbers of days with-precipitation ≥ 0.1 mm, ≥ 1.0 mm, ≥ 10.0 mm, ≥ 20.0 mm and ≥ 30.0 mm was analyzed also. All examined weather stations indicate that precipitation shortages are characteristic for the 90”s. Not only total precipitation amount indicate that, but also their classification presented according to Kaczorowska as well as precipitation - free periods.