Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Modeling household power consumption by residents of the Republic of Tajikistan
EN
The paper proposes modeling power consumption, taking into account factors and identifying the dependence of the geographical location above sea level and meteorological conditions of the location of residential consumers of the Republic of Tajikistan on power consumption. A mathematical and computer model has been proposed, which makes it possible to take into account the influence of changes in geographic locations above sea level and meteorological conditions in the area where household consumers are located on power consumption. To compare the results obtained in the models, the results were compared with the results of experimental values; for the experimental data, the readings of the electricity metering devices were taken, which showed high convergence.
PL
W pracy zaproponowano modelowanie zużycia energii elektrycznej z uwzględnieniem czynników oraz określenie zależności położenia geograficznego nad poziomem morza oraz warunków meteorologicznych lokalizacji odbiorców mieszkaniowych Republiki Tadżykistanu od zużycia energii elektrycznej. Zaproponowano model matematyczno-komputerowy, który umożliwia uwzględnienie wpływu zmian położenia geograficznego nad poziomem morza oraz warunków meteorologicznych na obszarze, na którym znajdują się gospodarstwa domowe, na zużycie energii. W celu porównania wyników uzyskanych w modelach wyniki porównano z wynikami wartości eksperymentalnych; dla danych eksperymentalnych pobrano odczyty urządzeń pomiarowych energii elektrycznej, które wykazały dużą zbieżność.
2
Content available remote Specifics of hydropower plant management in isolated power systems
EN
The paper describes the distinctive features of the isolated power system of Tajikistan, significant part of which is constituted by the hydropower plants; identifies the main problems of the electric power system of the Republic of Tajikistan in terms of power generation; describes specific features of HPP cascade management; proposes a method of determining the alternative fully drawn down level of the Norak HPP reservoir, taking into account the water level requirements in various water volume conditions from the point of view of power generation increase; estimates the economic efficiency of reducing the deficit of electricity in the power system with view to long-term optimization.
PL
W artykule opisano charakterystyczne cechy izolowanego systemu elektroenergetycznego Tadżykistanu, którego znaczną część stanowią elektrownie wodne; identyfikuje główne problemy systemu elektroenergetycznego Republiki Tadżykistanu w zakresie wytwarzania energii; opisuje specyficzne cechy zarządzania kaskadowego HPP; proponuje metodę określenia alternatywnego całkowicie obniżonego poziomu zbiornika Norak HPP z uwzględnieniem wymagań poziomu wody w różnych warunkach objętości wody z punktu widzenia przyrostu mocy; szacuje ekonomiczną efektywność redukcji deficytu energii elektrycznej w systemie elektroenergetycznym z myślą o długoterminowej optymalizacji.
3
Content available remote Analysis and comparison of energy indices of dc-dc pulse converters
EN
The computer simulation was used in order to analyze and compare circuit configurations of pulse-width converters and pulse-frequency converters. The principle of operation and main differences were described. The circuits of pulse-width converter and pulse-frequency converter were modelled in the Matlab software using blocks from the following library: Simulink / SimPowerSystem / Simscape. The block, which performs calculation of static and dynamic power losses of insulated gate bipolar transistor (IGBT), was created. The performance curves of the IGBT were approximated in order to calculate losses. The obtained curves quite accurately describe those of the IGBT in use (CM800HC-66H by MITSUBISHI). It was shown that dynamic losses can be reduced and conversion efficiency can be increased when using the pulse-frequency converters in comparison with pulse-width converters. It was noted that for values of duty cycle in the range from 0.1 to 0.5 the efficiency of pulse-frequency converter is significantly higher than that of pulse-width converter.
PL
Symulacja komputerowa została wykorzystana do analizy i porównania konfiguracji obwodów przetworników o szerokości impulsu i częstotliwości impulsu. Opisano zasadę działania i główne różnice. Obwody przetwornika szerokości impulsu i przetwornika częstotliwości impulsu zamodelowano w programie Matlab z wykorzystaniem bloków z biblioteki: Simulink / SimPowerSystem / Simscape. Stworzono blok, który wykonuje obliczenia statycznych i dynamicznych strat mocy tranzystora bipolarnego z izolowaną bramką (IGBT). Krzywe wydajności IGBT zostały przybliżone w celu obliczenia strat. Otrzymane krzywe dość dokładnie opisują krzywe zastosowanego tranzystora IGBT (CM800HC-66H firmy MITSUBISHI). Wykazano, że przy zastosowaniu przekształtników impulsowo-częstotliwościowych można zmniejszyć straty dynamiczne i zwiększyć sprawność konwersji w porównaniu z przekształtnikami o szerokości impulsu. Stwierdzono, że dla wartości współczynnika wypełnienia w zakresie od 0,1 do 0,5 sprawność przetwornika częstotliwości impulsów jest znacznie wyższa niż przetwornika szerokości impulsu.
EN
Complex ramified distribution power networks (DPN) 6-20 kV are characterized by large dimension, development dynamism, insufficient regime information completeness and reliability. Structured hierarchical-multilevel approach to the elementwise calculation of power losses in DPN is proposed. The DPN structural model is described. A substantive description of this approach is given on the example of ramified DPN with n nodes and m sections (transmission line and transformer) with a tree structure.
PL
Złożone rozgałęzione Sieci Elektroenergetyczne (DPN) 6-20 kV charakteryzują się dużym wymiarem, dynamiką rozwoju, niewystarczającą kompletnością informacji o reżimie i niezawodnością. Zaproponowano ustrukturyzowane hierarchiczno-wielopoziomowe podejście do pierwiastkowego obliczania strat mocy w DPN. Opisano model strukturalny DPN. Merytoryczny opis takiego podejścia podano na przykładzie rozgałęzionego DPN z węzłami n i odcinkami m (linia transmisyjna i transformator) o strukturze drzewa.
EN
This paper provides structured hierarchical-multilevel approach to the regimes and power losses calculation in distribution power networks of 35 kV and above at given loads and power source voltage level. It based on hierarchical-multilevel structure form representation of the radial power network initial graph and using of traditional engineering two-step method. This approach usage make it possible to obtain a universal (for arbitrary power network configuration and complexity) and efficient (in terms of the computational operations number and computer memory consumption) algorithm.
PL
W artykule przedstawiono ustrukturyzowane, hierarchiczno-wielopoziomowe podejście do obliczania zakresów i strat mocy w sieciach dystrybucyjnych o napięciu 35 kV i wyższych przy zadanych obciążeniach i poziomie napięcia źródła zasilania. Opiera się on na hierarchicznowielopoziomowej strukturze odwzorowania początkowego wykresu radialnej sieci elektroenergetycznej i zastosowaniu tradycyjnej dwuetapowej metody inżynierskiej. Zastosowanie tego podejścia pozwala na uzyskanie uniwersalnego (dla dowolnej konfiguracji i złożoności sieci elektroenergetycznej) i wydajnego (pod względem liczby operacji obliczeniowych i zajętości pamięci komputera) algorytm.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.