EN
Check valves are critical components of fluid systems and have various applications, including house appliances. This article presents a methodology for mapping geometry-specific constriction pressure loss as a function of flow and turbulence in a check valve. This study aimed to gain insight on which Ansys Fluent available turbulent energy dissipation model should be used for further design optimization. This methodology consists of a statistical comparison of computational fluid dynamics (CFD) simulation results obtained using the turbulent energy dissipation models. The key components of the simulation process are discussed. The study’s main results are a comparison of empirical results among flow models’ estimated pressure loss, shown as a function of flow rate in specific geometry and identification of the most suitable model for the considered application. This study concludes that the K-Epsilon (Standard) model best represents the empirically measured behavior of naturally occurring flow energy losses in the considered geometry.