Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 12

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Problem of Post-operative infections of implant materials caused by bacterial adhesion to their surfaces is very serious. Enhancement of antibacterial properties is potentially beneficial for biomaterials value. Therefore, the metallic and metallic oxide nanoparticles attract particular attention as antimicrobial factors. The aim of this work was to create nanotubular (NT) oxide layers on Ti with the addition of ZnO nanoparticles, designed for antibacterial biomedical coatings. Antimicrobial activities of titanium, TiO2 NT and ZnO/TiO2 NT surfaces were evaluated against bacterial strain typical for orthopaedic infections: S. epidermidis. TiO2 NT alone killed the free bacterial cells significantly but promoted their adhesion to the surfaces. The presence of moderate amount of ZnO nanoparticles significantly reduced the S. epidermidis cells adhesion and viability of bacterial cells in contact with modified surfaces. However, higher amount of loaded nanoZnO showed the reduced antimicrobial properties than the medium amount, suggesting the overdose effect.
EN
Problem of post-operative infections of implant materials caused by bacterial adhesion to their surfaces is very serious. Enhancement of antibacterial properties is potentially beneficial for biomaterials value. Therefore, the metallic and metallic oxide nanoparticles attract particular attention as antimicrobial factors. The aim of this work was to create nanotubular (NT) oxide layers on Ti with the addition of ZnO nanoparticles, designed for antibacterial biomedical coatings. Antimicrobial activities of titanium, TiO2 NT and ZnO/TiO2 NT surfaces were evaluated against bacterial strain typical for orthopaedic infections: S. epidermidis. TiO2 NT alone killed the free bacterial cells significantly but promoted their adhesion to the surfaces. The presence of moderate amount of ZnO nanoparticles significantly reduced the S. epidermidis cells adhesion and viability of bacterial cells in contact with modified surfaces. However, higher amount of loaded nanoZnO showed the reduced antimicrobial properties than the medium amount, suggesting the overdose effect.
PL
Przebadano adhezję komórek Staphylococcus epidermidis do powierzchni tytanowych modyfikowanych warstwami TiN, SiO2-TiO2 i hydroksyapatytu. Powierzchnie tytanowe stały się odporne na adhezję bakterii, bez względu na to czy warstwy SiO2-TiO2 zostały wytworzone na czystym lub modyfikowanym warstwą TiN tytanie. Kiedy tytan modyfikowany warstwami SiO2-TiO2 lub TiN/SiO2-TiO2 był dodatkowo pokryty warstwą hydroksyapatytu, podłoże również było znacząco oporne na adhezję S. epidermidis. Duże ilości bio-filmu bakteryjnego zaobserwowano jedynie na powierzchniach tytanowych niemodyfikowanych (szlifowanych i polerowanych) i pokrytych TiN.
EN
Adhesion of Staphylococcus epidermidis cells to titanium surfaces modified with TiN, SiO-TiO2 and hydroxyapatite layers was tested. Titanium surfaces became resistant to adhesion of bacteria, no matter if SiO2-TiO2 layer was deposited on pure or TiN-modified titanium. When titanium modified with SiO2-TiO2 or TiN/SiO2-TiO2 layers was additionally covered with hydroxy-apatite coatings, the substrates were also significantly resistant to S. epidermidis adhesion. Abundant presence of bacterial biofilm was observed only on non-modified (ground and polished) and TiN-coated titanium surfaces.
PL
Powszechnie znana wada hydroksyapatowego materiału implantacyjnego w postaci granul dotyczy braku poręczności chirurgicznej. Problem ten może być rozwiązany poprzez przygotowanie odpowiedniego materiału kompozytowego. Wytworzono nowy małoplastyczny organiczno/nieorganiczny kompozyt posiadający korzystne właściwości mechaniczne, który okazał się być zdolnym do częściowego dopasowywania do kształtu i wymiarów miejsca implantacyjnego. Kompozyt może być suszony i ponownie nasączany, daje się przechowywać przez co najmniej 2 lata i sterylizować bez utraty swoich właściwości. Jego parametry mechaniczne przypominają te, które wykazuje kość gąbczasta. Po implantacji do przetok ustno-nosowych w modelu psim, okazał się być dobrym materiałem w procesie ich leczenia, zapobiegając zapaleniom nosa i zachłystowemu zapaleniu płuc. Te właściwości czynią opisany kompozyt obiecującym materiałem dla wypełnień ubytków kości.
EN
Commonly known disadvantage of granular hydroxyapatite implantation material concerns the lack of its surgical handiness. This problem can be solved by preparing the suitable composite material. A new low ductile organic/inorganic composite possessing profitable mechanical properties has been created and it was found to be able to adapt to some ex-tent to shape and dimensions of implantation site. The composite can be dried and soaked again, may be stored for at least 2 years and sterilized without loss of its properties. Its mechanical parameters resemble those of spongy bone. After implantation into oronasal fistulae dog model, it served as a good material for fistula’s repair, preventing appearance of nasal rhinitis and aspiration pneumonia. These properties make the composite a promising biomaterial for filling of bone defects.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.