The article presents the idea of a system enabling effective control of production processes. A high level of automation and control of production processes plays a key role in maintaining a high level of competitiveness of each enterprise. The proposed system concept consists of a network of distributed sensors that enable the measurement of many process parameters, manufacturing resources and the state of the machine park. The described control system uses both wired and wireless communication. The implemented communication systems will enable obtaining data from various sensors and other subsystems installed in enterprises, as well as obtaining data from new systems and sensors used to measure all types of processes, from production set-up to the final product. The described solution includes the use of process tomography sensors based on electrical tomography. The conducted research shows that the use of tomographic methods enables effective management of the intelligent structure of companies in the scope of manufacturing processes control.
PL
W artykule przedstawiono ideę systemu umożliwiającego efektywną kontrolę procesów produkcyjnych. Wysoki poziom automatyzacji i kontroli procesów produkcyjnych odgrywa kluczową rolę w utrzymaniu wysokiego poziomu konkurencyjności każdego przedsiębiorstwa. Proponowana koncepcja systemu składa się z sieci rozproszonych czujników, które umożliwiają pomiar wielu parametrów procesu, zasobów produkcyjnych i stanu parku maszynowego. Opisany system sterowania wykorzystuje zarówno komunikację przewodową, jak i bezprzewodową. Zaimplementowane systemy komunikacyjne umożliwią pozyskiwanie danych z różnych czujników i z innych podsystemów zainstalowanych w przedsiębiorstwach, a także uzyskiwanie danych z nowoopracowanych systemów i czujników używanych do pomiaru wszystkich typów procesów, począwszy od przygotowania produkcji aż do produktu końcowego. Opisane rozwiązanie obejmuje wykorzystanie czujników tomografii procesowej w oparciu o tomografię elektryczną. Przeprowadzone badania dowodzą, że zastosowanie metod tomograficznych umożliwia efektywne zarządzanie inteligentną strukturą firmy w zakresie sterowania procesami produkcyjnymi.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The subject of the presented article are studies on the automatic and reliable method of observing flood embankments using a multisensor integrated monitoring system. Designing and developing this type of system is a serious challenge, mainly due to the need to involve experienced specialists and scientists from various fields of science and technology. An element of such a system is the electrical tomograph presented in the article for non-destructive testing. With the help of the presented tomographic system, it is possible to carry out tests of technical objects such as flood barriers and industrial tanks. The described monitoring system, in addition to the software, consists of many subsystems and components, of which sensors play a special role. With their help, the system measures various types of physical parameters, including: wind speed, ambient temperature, voltage, etc. In this text, the authors focused on one of the subsystems of the described solution, namely on the electrical tomography. The principle of operation of the discussed system is based on the observation of the environment using many differentiated, intelligent measurement methods. In addition, an analytical module based on computational intelligence algorithms is an important element of the monitoring system. This module is used to analyze and visualize input data.
PL
Przedmiotem prezentowanego artykułu są badania nad automatyczną i niezawodną metodą obserwacji obwałowań przeciwpowodziowych za pomocą wieloczujnikowego zintegrowanego systemu monitorowania. Projektowanie i opracowywanie tego typu systemu stanowi poważne wyzwanie, głównie ze względu na konieczność zaangażowania doświadczonych specjalistów i naukowców z różnych dziedzin nauki i techniki. Elementem takiego systemu jest tomograf elektryczny umożliwiający badania nieniszczące. Za pomocą systemu tomograficznego można przeprowadzać skanowanie obiektów technicznych, takich jak zapory przeciwpowodziowe i zbiorniki przemysłowe. Opisywany system monitorowania, oprócz oprogramowania, składa się z wielu podsystemów i komponentów, z których czujniki odgrywają szczególną rolę. Za ich pomocą system mierzy różne rodzaje parametrów, w tym: prędkość wiatru, temperaturę otoczenia, napięcie itp. W artykule skoncentrowano się na jednym z podsystemów przedmiotowego systemu, a mianowicie na tomografii elektrycznej. Zasada działania systemu monitorowania oparta jest na obserwacji środowiska przy użyciu wielu zróżnicowanych, inteligentnych metod pomiarowych. Ponadto ważnym elementem systemu jest moduł analityczny oparty na algorytmach inteligencji obliczeniowej. Moduł ten służy do analizy i wizualizacji danych wejściowych.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper presents solutions examining the brick wall dampness using electrical tomography. Different prototype measuring systems based on electrical tomography devices and the laboratory measurement devices were prepared. The prepared constructions contain 16 and 32 electrodes for measuring moisture in the brick wall on one side and two-sided. Electrical tomography, which is based on measuring potential difference, can be used to inspect historical buildings. The way in which we can define state of wall depends on the fact that every material has the unique conductance. To realize this measurement there are necessary electrodes, meters, AC generator, multiplexer and PC with LABview or the tomography device.
PL
W artykule przedstawiono rozwiązania sprawdzające wilgotność murów przy użyciu tomografii elektrycznej. Przygotowano różne prototypowe systemy pomiarowe oparte na elektrycznych urządzeniach tomograficznych oraz systemie laboratoryjnym. Przygotowane konstrukcje zawierają 16 i 32 elektrody do pomiaru zawilgocenia murów z cegły z jednej strony i z obu stron. Do kontroli zabytkowych budynków można wykorzystać tomografię elektryczną, która oparta jest na pomiarze różnicy potencjałów. Sposób, w jaki możemy określić stan murów, zależy od tego, że każdy materiał ma unikalną konduktywność. Do wykonania pomiarów potrzebne są elektrody, mierniki, generatory prądu zmiennego, multiplekser i PC z LABview lub urządzenie tomograficzne.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The presented research presents a method of using the smallest angles regression algorithm to solve the inverse problem in electrical impedance tomography in relation to a damp wall. Highly correlated predictors in linear models make it difficult to precisely determine the influence of these predictors on the output variable. The standard application of the least-squares method to estimate unknown parameters may lead to a poor forecast. Adding a penalty parameter depending on quantities of parameters to the least square criterion allows us to determine the biased estimators but also to reduce the variance of estimators.
PL
Przedstawione badania dotyczą sposobu wykorzystania algorytmu regresji najmniejszego kąta (LARS) do rozwiązania problemu odwrotnego w elektrycznej tomografii impedancyjnej w odniesieniu do wilgotnej ściany. Wysoce skorelowane predyktory w modelach liniowych utrudniają precyzyjne określenie wpływu tych predyktorów na zmienną wyjściową. Standardowe zastosowanie metody najmniejszych kwadratów do oszacowania nieznanych parametrów może prowadzić do złej prognozy. Dodanie elementu kary w zależności od ilości parametrów do kryterium najmniejszego kwadratu pozwala nam określić estymatory obciążenia, a także zmniejszyć wariancję estymatorów.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Article presents methods to identify the properties and reconstruction of the images. A special e-Medicus system to analysis and compare data or pictures was prepared. The solution shows the architecture of the system collecting and analysing data. The internal conductivity distribution is recovered from the measured boundary voltage data. New results of a reconstruction of a numerically simulated phantom are presented. The reconstruction task is a nonlinear and ill-posed inverse problem, whose solution calls for special regularized algorithms. New methods have also been implemented to identify arbitrary number of phases for the segmentation problem. With the use of modern algorithms, it can obtain a quicker diagnosis and automatically marking areas of the interest region in medical images.
PL
Artykuł przedstawia metody do identyfikacji właściwości i rekonstrukcji obrazów. Przygotowano specjalny system e-Medicus do analizy i porównywania danych oraz obrazów. Rozwiązanie przedstawia architekturę systemu zbierającego i analizującego dane. Rozkład wewnętrznego przewodnictwa jest uzyskiwany z mierzonych danych dotyczących granicy napięć. Przedstawiono nowe wyniki rekonstrukcji symulowanego numerycznie fantomu. Problem rekonstrukcji jest nieliniowy i źle postawiony (zagadnienie odwrotne), którego rozwiązanie wymaga regularyzacji. Zaimplementowano również nowe metody do zidentyfikowania dowolnej liczby faz dla problemu segmentacji. Dzięki zastosowaniu nowoczesnych algorytmów uzyskuje się szybszą diagnozę i automatycznie oznacza interesujące obszary w obrazach medycznych.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono nową efektywną metodę obrazowania, która może być zastosowana w tomografii ultradźwiękowej i radiowej. Proponowana metoda poprzez zmianę kształtu piksela prowadzi do znacznego uproszczenia algorytmu, kosztem niewielkich przybliżeń. Jak udowodniono w pracy, przybliżenia te nie mają istotnego znaczenia co do czytelności obrazu, kilkunastokrotnie przyspieszając jego uzyskanie.
XX
This article presents a new effective imaging method that can be applied in ultrasonic and radio tomography. The proposed method by changing the shape of the pixels leads to a substantial simplification of the algorithm at the cost of small approximations. As proved in the work, these approximations do not have a significant impact on the readability of the image which is several times faster.
An image reconstruction with use of EIT method has been found useful in many areas of medical, industrial and environmental applications. Papers show that computational systems used for image reconstructions are utilizing parallel and distributed computations and multi-tier architecture, as well as monolithic architecture. The aim of our research is to define an analytical system architecture that will be able to combine a variety of image reconstruction algorithms with their representations in different programming languages. Based on examples described in different proceedings and research papers, a microservices architecture seems to be an interesting alternative to the monolithic one.
PL
Zaprezentowano postępy prac związanych z budową system analitycznego służącego do rekonstrukcji obrazów obiektów badanych za pomocą elektrycznej tomografii impedancyjnej. Celem system jest elastyczność pozwalająca na integrację wewnątrz jednego system modułów analitycznych bazujących na różnych algorytmach rekonstrukcji obrazu identyfikowanego obiektu. Kolejnym ważnym wymaganiem jest możliwość oprogramowania modułów analitycznych za pomocą najczęściej wykorzystywanych w tej dziedzinie językach programowania. System zapewnia komunikację z urządzeniem za pośrednictwem łączy internetowych, co pozwala na zdalne sterowanie i pobieranie wyników pomiarów. Dodatkowym założeniem stawianym aplikacji jest możliwość korzystania z dowolnego źródła danych (urządzenie typu tomograf, baza danych, systemy plików) poddawanych analizie, a wyniki rekonstrukcji mają być dostępne dla każdego urządzenia komputerowego. Zaprezentowano dwa rodzaje architektury aplikacji, monolityczną i opartą o mikro usługi.
The paper deals with the problem of works transport organization in logistic center with the use of artificial intelligence algorithms. The presented approach is based on non-changeable path during travel along a given loop. The ordered set of containers requesting transport service was determined by fuzzy logic, while the sequence of containers in a loop was optimized by genetic algorithms. A solution for semi-autonomous transport vehicles wherein the control system informs the driver about optimal route was presented. The obtained solution was verified by a computer simulation.
PL
Artykuł dotyczy problematyki sterowania transportem wewnątrzzakładowym w zautomatyzowanych centrach logistycznych z zastosowaniem metod sztucznej inteligencji. Zaprezentowane podejście zakłada predykcję niezmiennej trasy przejazdu środka transportu. Kolejność zbioru regałów wymagających obsługi transportowej jest determinowana przez logikę rozmytą, natomiast do optymalizacja trasy przejazdu wykorzystano algorytmy genetyczne. Zaprezentowano koncepcję środka transportu, w którym system sterowania informuje kierowcę dokąd ma jechać. Uzyskane rozwiązanie zostało zweryfikowane z wykorzystaniem metod symulacji komputerowej.
The results of ultrasonic imaging with the aid of an algorithm with the virtual rays is presented in this paper. The signal associated with the virtual rays is calculated as an arithmetical mean value of the signals of the rays surrounding the virtual one. Developed algorithm was tested on synthetic free noise data then polluted synthetic data in order to move for the real measurements. Conclusions about the imaging with new algorithm are not obvious. In same cases the significant improvement was achieved but in some not.
PL
W pracy przedstawiono rezultaty działania algorytmu obrazowania ultradźwiękowego z dodatkowymi wirtualnymi promieniami. Sygnał odpowiadający wirtualnym promieniom jest wyliczany jako średnia arytmetyczna rzeczywistych sygnałów pomiarowych odpowiadających promieniom otaczającym dany promień wirtualny. Zaproponowany algorytm najpierw przetestowano na danych syntetycznych niezaszumionych, następnie na danych zaszumionych aby następnie przejść do danych pomiarowych. Wnioski na temat tego czy promienie wirtualne mają szanse podnieść jakość obrazowania nie są jednoznaczne. W niektórych przypadkach jakość jest znacznie lepsza a w innych nie.
The solution shows the architecture of the system collecting and analyzing data. There was tried to develop algorithms to image segmentation. These algorithms are needed to identify arbitrary number of phases for the segmentation problem. With the use of algorithms such as the level set method, neural networks and deep learning methods, it can obtain a quicker diagnosis and automatically marking areas of the interest region in medical images.
PL
Rozwiązanie pokazuje architekturę systemu zbierającego i analizującego dane. Opracowano algorytmy segmentacji obrazu. Algorytmy te są potrzebne do identyfikacji dowolnej liczby faz dla problemu segmentacji. Dzięki zastosowaniu algorytmów, takich jak metoda zbiorów poziomicowych, sieci neuronowych i metody głębokiego uczenia się, można uzyskać szybszą diagnozę i automatyczne oznaczanie obszarów w regionie zainteresowania w obrazach medycznych.
The article contains a description of the quality control system based on optical detection algorithms. It plays an increasingly important in the production process. The development of new systems based on the technology of optical detection methods to a large degree can improve the production process at different stages.
PL
Artykuł zawiera opis systemu kontroli jakości oparty na optycznych algorytmach detekcji. Wykrywanie uszkodzeń odgrywa coraz większą rolę w procesie produkcyjnym. Opracowanie nowych systemów opartych na technologiach optycznych metod wykrywania w dużym stopniu może usprawnić proces produkcji na różnych jego etapach.
The article presents an idea of a production process control system. Advanced automation and control of production processes play a key role in maintaining competitiveness. The proposed solution consists of sensor networks for measurement process parameters, production resources and equipment state. The system uses wired and wireless communication, which gives possibility to acquisition data from existing in enterprise sensors and systems as well as acquisition data from new systems and sensors used to measure all processes, starting from production preparation to the final product. The solution contains process tomography sensors based on electrical capacitance tomography, electrical impedance tomography and ultrasound tomography. The use of tomographic methods enables to manage the intelligent structure of the companies in terms of processes and products. Industrial tomography enables observation of physical and chemical phenomena without the need to penetrate inside. It will enable the optimization and autooptimization of design processes and production. Such solutions can operate autonomously, monitor and control measurements. All sensors return to the system continuous data about state of processes in some technologically closed objects like fermenters. Process tomography can also be used to acquisition data about a flow of liquids and loose ingredients in pipeline based on transport systems. Data acquired from sensors are collected in data warehouses in order to future processing and building the knowledge base. The results of the data analysis are showed in user control panels and are used directly in the control of the production process to increase the efficiency and quality of the products. Control methods cover issues related to the processing of data obtained from various sensors located at nodes. Monitoring takes place within the scope of acquired and processed data and parameter automation.
PL
W artykule przedstawiono ideę systemu kontroli procesu produkcyjnego. Zaawansowana automatyzacja i kontrola procesów produkcyjnych odgrywają kluczową rolę w utrzymaniu konkurencyjności. Proponowane rozwiązanie składa się z sieci czujników do pomiaru parametrów procesu, zasobów produkcyjnych i stanu wyposażenia. System wykorzystuje komunikację przewodową i bezprzewodową, która umożliwia pozyskiwanie danych z istniejących w przedsiębiorstwach czujników i systemów, a także pozyskiwanie danych z nowych systemów i czujników używanych do pomiaru wszystkich procesów, począwszy od przygotowania produkcji do produktu końcowego. Rozwiązanie zawiera czujniki tomografii procesowej oparte na elektrycznej tomografii pojemnościowej, elektrycznej tomografii impedancyjnej i tomografii ultradźwiękowej. Zastosowanie metod tomograficznych umożliwia zarządzanie inteligentną strukturą firm pod względem procesów i produktów. Tomografia przemysłowa umożliwia obserwację zjawisk fizycznych i chemicznych bez potrzeby penetracji wewnątrz. Umożliwi to optymalizację i automatyczną procesów projektowych i produkcji. Takie rozwiązania mogą działać autonomicznie, monitorować i kontrolować pomiary. Wszystkie czujniki przekazują do systemu ciągłe dane o stanie procesów w niektórych technologicznie zamkniętych obiektach, takich jak fermentory. Tomografia procesowa może być również wykorzystywana do pozyskiwania danych o przepływie płynów i luźnych składników w rurociągu w oparciu o systemy transportowe. Dane uzyskane z czujników gromadzone są w hurtowniach danych w celu ich dalszego przetwarzania i budowania bazy wiedzy. Wyniki analizy danych są wyświetlane w panelach sterowania użytkownika i są wykorzystywane bezpośrednio w kontroli procesu produkcyjnego w celu zwiększenia wydajności i jakości produktów. Metody kontroli obejmują zagadnienia związane z przetwarzaniem danych uzyskanych z różnych czujników zlokalizowanych w węzłach. Monitorowanie odbywa się w ramach pozyskanej i przetwarzanej automatyzacji danych i parametrów.
In this paper the terrain electrical resistance tomograph was presented. Its aim is to verify the repeatability of test results by eliminating laboratory equipment, and to validate the use of simple and cheap electronics to the structure of the ERT. Electrical resistance tomography, which is based on measuring potential difference, can be used to calculate conductivity.
PL
W niniejszym artykule przedstawiono konstrukcję tomografu rezystancyjnego. Jego celem jest weryfikacja powtarzalności wyników badań poprzez wyeliminowanie sprzętu laboratoryjnego oraz potwierdzenie zastosowania prostej i taniej elektroniki do struktury ERT. Do obliczenia przewodnictwa można wykorzystać elektryczną tomografię rezystancyjną, która opiera się na pomiarze różnicy potencjałów.
The paper deals with the design of data analysis systems for business process automation. The main goal of the project is to develop an innovative system for analyzing multisource data, business data mining processes, and as a result the creation and sharing of new improved procedures and solutions.
PL
Artykuł dotyczy projektowania systemów analizy danych do automatyzacji procesów biznesowych. Głównym celem projektu jest opracowanie innowacyjnego systemu do analizy danych wieloźródłowych, procesów eksploracji danych biznesowych, a co za tym idzie tworzenie i udostępnianie nowych ulepszonych procedur i rozwiązań.
In this work, there were implemented methods to analyze and segmentation medical images by using different kind of algorithms. The solution shows the architecture of the system collecting and analyzing data. There was tried to develop an algorithm for level set method applied to piecewise constant image segmentation. These algorithms are needed to identify arbitrary number of phases for the segmentation problem. With the use of modern algorithms, it can obtain a quicker diagnosis and automatically marking areas of the interest region in medical images.
PL
W pracy zaimplementowano metody analizy i segmentacji obrazów medycznych przy użyciu różnych algorytmów. Rozwiązanie pokazuje architekturę systemu zbierającego i analizującego dane. Podjęto próbę opracowania algorytmu dla metody zbiorów poziomicowych stosowanej do fragmentarycznej, stałej segmentacji obrazu. Metody te są potrzebne do identyfikacji dowolnej liczby faz dla problemu segmentacji. Dzięki zastosowaniu nowoczesnych algorytmów można uzyskać szybszą diagnozę i automatyczne oznaczanie obszarów w regionach zainteresowania w obrazach medycznych.
The article presents an innovative concept of enhancing the flood embankments and landfills monitoring. The key advantage of such a solution is to obtain a more detailed distribution of components within a flood barrier. It leads to more early and sufficient threat detection, considering the exploitation of the building, thus - a vast enhancement of an embankment’s performance. The method is based on implementing a neural system, composed of a number of parallelly-working neural networks. Each of them generate a singular point of final output view. By implementing such monitoring measures it is possible to successfully reconstruct two-and-three dimensional models of flood barriers and dams - including possible breaches and damages within its inner structure. An important advantage of such a solution is the possibility of replacing the systems that monitor hydrotechnical facilities pixel-by- pixel by neural imaging. The performed research leads to solving the problem of low resolution of such images. As this problem was of crucial value to tomographic imaging method, it was a main obstacle to the development of neural reconstruction method. Moreover, as the results may be obtained in real-time and at various levels, these new functionalities stand out in comparison to currently used methods for monitoring protective banks.
PL
W artykule zaprezentowano nowatorską koncepcję usprawnienia monitoringu wałów i zapór przeciwpowodziowych. Główną przewagą nowego rozwiązania nad znanymi metodami jest uzyskanie dokładniejszego rozkładu komponentów wnętrza zapory, co zasadniczo przyczynia się do wczesnego i niezawodnego wykrycia zagrożeń związanych z eksploatacją tego typu budowli. Dzięki temu, zastosowanie nowej metody spowoduje wzrost niezawodności zabezpieczeń przeciwpowodziowych. W opisywanej metodzie założono wytrenowanie systemu neuronowego złożonego z wielu działających równolegle sieci neuronowych, z których każda generuje pojedynczy punkt obrazu wyjściowego. Powyższy sposób, uwzględniający jednoczesne zastosowanie wielu sieci neuronowych, umożliwia skuteczną realizację trudnych zagadnień rekonstrukcji obrazów dwu i trój-wymiarowych, w tym obrazowanie uszkodzeń i przecieków wnętrza zapór przeciwpowodziowych. Ważną zaletą prezentowanej metody jest możliwość zastąpienia obrazowaniem neuronowym wielu innych, obecnie stosowanych systemów, które monitorują budowle hydrotechniczne w sposób punktowy. Przeprowadzone badania umożliwiają rozwiązanie problemu niskiej rozdzielczości obrazów tomograficznych, co stanowi główną barierę rozwoju tych metod w odniesieniu do dużych budowli ziemnych. Poprawa rozdzielczości rekonstruowanych obrazów, a także możliwość ich uzyskiwania w różnych przekrojach w czasie rzeczywistym, są nowymi funkcjonalnościami, które wyróżniają obrazowanie neuronowe na tle obecnie stosowanych metod monitoringu wałów i zapór przeciwpowodziowych.
17
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This article presents the design of the device with active electrodes to examine the landfill and flood embankments. The presented solution was based on electrical resistance tomography (ERT). The basic information about the built model system is given. There was described the concept of active electrodes and measuring equipment for data acquisition. Electrical resistance tomography, which is based on measuring potential difference, can be used to calculate conductivity. The problem depends on the fact that every material has unique conductance. Its aim was to verify the repeatability of test results by eliminating laboratory equipment, and to validate the use of simple and cheap electronics to the structure of the ERT.
PL
W artykule przedstawiono projekt urządzenia z aktywnymi elektrodami w celu zbadania składowisk odpadów i wałów przeciwpowodziowych. Przedstawione rozwiązanie oparte jest na elektrycznej tomografii rezystancyjnej (ERT). Podano podstawowe informacje o zbudowanym modelu systemu. Opisano koncepcję aktywnych elektrod i przyrządów pomiarowych do gromadzenia danych. Do obliczania konduktywności została zastosowana elektryczna tomografia rezystancyjna, która oparta jest na pomiarze różnicy potencjałów. W zagadnieniu tym, problem polega na tym, że każdy materiał ma unikalną przewodność. Celem zbudowanego systemu z urządzeniem ERT jest zweryfikowanie powtarzalności wyników testów poprzez wyeliminowanie sprzętu laboratoryjnego w bezpośrednich pomiarach środowiskowych.
18
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
In this work, there was presented authoring system to exam the medical images by using statistical methods, topological algorithms and computational intelligence methods. These methods are used to identify the properties for the images. There was prepared a special e-Medicus system to machine learning, analysis and compare data and pictures. The solution shows the architecture of the system collecting and analysing data. There was tried to develop an algorithm for level set method (LSM) applied to piecewise constant image segmentation. These algorithms are needed to identify arbitrary number of phases for the segmentation problem. The image segmentation refers to the process of partitioning a digital image into multiple regions. There is typically used to locate objects and boundaries in images.
PL
W artykule, został przedstawiony autorski system do badania obrazów medycznych przy użyciu metod statystycznych, algorytmów inteligencji obliczeniowej i metod topologicznych. Metody te stosuje się w celu identyfikowania właściwości obrazów. Przygotowano specjalny system e-Medicus do uczenia maszynowego, analizy i porównywania danych i obrazów. Rozwiązanie przedstawia architekturę systemu do gromadzenia i analizy danych. Opracowano algorytmy oparte na metodzie zbiorów poziomicowych (MZP) jako odcinkowo stałej segmentacji obrazu. Algorytmy te są potrzebne do identyfikacji dowolnej liczby faz dla problemu segmentacji, która odnosi się do procesu dzielenia cyfrowego obrazu w różnych regionach. Używana jest zwykle do lokalizacji obiektów i brzegów w obrazach.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Modern production processes are increasingly complicated while customers require higher quality products at the lowest prices. This situation increases the importance of process optimization. Article contains description of the measurement system based on electrical capacitance tomography and optical detection techniques for optimization and production quality control. The most characteristic features of presented project are compact size of data acquisition module and its low energy demand. Complexity and cost of electrical capacitance tomography systems implementation into manufacturing processes as well as substantial size of equipment are the main reasons of their absence in the industry.
PL
Nowoczesne procesy produkcyjne są coraz bardziej skomplikowane, a klienci wymagają wysokiej jakości produktów po najniższych cenach. Ta sytuacja zwiększa znaczenie optymalizacji procesu. Artykuł zawiera opis systemu pomiarowego oparty na elektrycznej tomografii pojemnościowej oraz optycznych technikach wykrywania w celu optymalizacji i kontroli jakości produkcji. Najbardziej charakterystycznymi cechami prezentowanego rozwiązania są niewielkie wymiary modułu gromadzenia danych i niski zapotrzebowanie na energię. Złożoność i koszt wdrożenia systemów elektroenergetycznych tomografii pojemnościowej do procesów produkcyjnych oraz znaczny rozmiar sprzętu stanowią główne przyczyny ich nieobecności w branży.
This paper refers to the cases of the use of Artificial Neural Networks and Convolutional Neural Networks in impedance tomography. Machine Learning methods can be used to teach computers different technical problems. The efficient use of conventional artificial neural networks in tomography is possible able to effectively visualize objects. The first step of implementation Deep Learning methods in Electrical Impedance Tomography was performed in this work.
PL
W artykule zaprezentowano dwa przypadki dotyczące zastosowania sztucznych sieci neuronowych i konwolucyjnych sieci neuronowych w tomografii impedancyjnej. Uczenie maszynowe może znaleźć zastosowanie przy rozwiązywaniu różnorodnych problemów technicznych. W tomograficznej rekonstrukcji obrazów można stosować konwencjonalne sieci neuronowe. W niniejszej pracy przedstawiono przykład zastosowania metod głębokiego uczenia w obszarze elektrycznej tomografii impedancyjnej.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.