EN
Wastewater treatment plants (WWTPs) have been recognized as a source of odors and microbial pathogens to the outdoor air. The results of many studies revealed that high amounts of microorganisms are not only present in the stream of wastewater or sludges but also in the bioaerosols that are generated during the different stages of the wastewater treatment. Hence, possible migration of biological contaminants into the interiors cannot be excluded. However, there is a knowledge gap in an assessment of the microbiological indoor air quality of the facilities located at WWTPs. The aim of this study was to evaluate the level of outdoor microbial air contamination upon the indoor environment based on the determined outdoor to indoor (O/I) ratios. The sampling of airborne bacteria and fungi was conducted in three replications with the sedimentation and impaction method, during a one-year survey in ten technological and office buildings as well as their vicinity, at the municipal wastewater treatment plant of Lublin (Poland). Moreover, the cleanliness of hand contact surfaces in staff rooms was examined (Rodac plates). Additionally, API identification of bacteria and fungi was carried out. The highest concentration of total bacteria count (3617 CFU/m3) and fungi in bioaerosols (5386 CFU/m3) was detected in the air around the sewage pumping station, close to the aeration tanks. P. fluorescens was found in the air around the grit chamber (78 CFU/m3). The majority of the examined indoor air samples were characterized with different levels of microbiological contamination – from non-polluted to moderately polluted. The number of total bacteria counts ranged from 180 to 4679 CFU/m3. The highest estimated indoor fungi concentration was 4022 CFU/m3. The controlled surfaces were mostly contaminated with the Actinomycetes and Coliform bacteria. No Salmonella sp. were detected. The bacteria from the Enetrobacteriaceae family were commonly isolated from the indoor and outdoor air samples. The obtained data can be used to devise further guidelines facilitating control and management of WWTP to avoid or minimize the staff exposure.
PL
W artykule przestawiono informacje na temat dostępnych technik odpylania i dezynfekcji powietrza na potrzeby instalacji wentylacji i klimatyzacji w obiektach szpitalnych ze szczególnym uwzględnieniem systemów opartych na wykorzystaniu fotokatalizy i pola elektrostatycznego. Obiekty szpitalne z racji pełnionej funkcji są miejscem szczególnego narażenia na organizmy chorobotwórcze zarówno wśród personelu jak i pacjentów. Stąd istnieje tam konieczność nie tylko uzdatniania powietrza, ale jego oczyszczania celem usunięcia obecnych w nim patogenów. W artykule przestawiono informacje na temat dostępnych technik odpylania i dezynfekcji powietrza na potrzeby instalacji wentylacji i klimatyzacji w obiektach szpitalnych ze szczególnym uwzględnieniem systemów opartych na wykorzystaniu pola elektrostatycznego.
EN
The paper presents the information on the available techniques of air disinfection for the needs of ventilation and air conditioning systems in hospital facilities, with particular emphasis on the systems based on the use of photocatalysis and an electrostatic field. Hospital facilities, due to their function, are a place of particular exposure to pathogenic organisms, both among staff and patients. Hence, there is a need not only for air treatment, but also for its purification in order to remove the pathogens present in it. The paper presents the information on the available techniques of air disinfection for the needs of ventilation and air conditioning systems in hospital facilities, with particular emphasis on the systems based on the use of anelectrostatic field.
EN
This paper discusses the possibilities and limitations of using biophilic installations to improve the indoor air quality in residential and commercial spaces. Modular plant systems can provide the support or, in smaller facilities, even an alternative to the conventional indoor air purification techniques, such as filtration. The unquestionable advantage of green walls is their comprehensive influence on the indoor air quality by shaping both appropriate thermal and humidity conditions as well as the chemical air composition. However, these constructions are not mechanical systems and therefore, the effectiveness of these specific types of living air purifiers in removing gaseous pollutants and particulate matter cannot be expected to match the level of traditional systems.
PL
W pracy omówiono możliwości i ograniczenia wykorzystania instalacji biofilicznych do poprawy jakości powietrza wewnętrznego w przestrzeniach mieszkalnych i komercyjnych. Roślinne systemy modułowe mogą stanowić wsparcie lub w mniejszych obiektach alternatywę dla konwencjonalnych technik oczyszczania powietrza wewnętrznego jakim jest filtracja. Niekwestionowaną zaletą zielonych ścian jest ich kompleksowy wpływ na jakość powietrza wewnętrznego poprzez kształtowanie zarówno odpowiednich warunków cieplno-wilgotnościowych jaki i składu chemicznego powietrza. Nie są to jednak układy mechaniczne i nie można oczekiwać, aby te swoistego rodzaju żywe oczyszczacze powietrza osiągały skuteczności w usuwaniu zanieczyszczeń gazowych i pyłowych na poziomie tradycyjnych systemów.
4
Content available Air Purification in Sustainable Buildings
EN
This paper concerns the issue of indoor air purification techniques in sustainable public buildings and the residential sector. One of the requirements of sustainable construction is to reduce the energy costs, minimize waste, improve the well-being of users and create green space. The most important certification systems for green (ecological) buildings such as LEED or BREEAM also include the assessment of the indoor environment in terms of the air quality, noise level, building acoustics and energy consumption. Traditional air treatment and purification systems require the use of numerous devices, air transport systems, which are energy-consuming. It is necessary to clean or replace the working elements periodically. The alternative is biophilic installations (green walls) based on the natural properties of plants for removing gaseous pollutants, particulate matter and even bioaerosols from the air. Plants improve humidity, regulate the carbon dioxide concentration, ionize the air and suppress noise. However, the processes of photocatalytic degradation of gaseous compounds are a very promising method of removing impurities, due to low costs, mild process conditions (temperature and pressure) and the possibility of complete mineralization of impurities.
PL
Praca dotyczy zagadnienia technik oczyszczania powietrza wewnętrznego w zrównoważonych budynkach użyteczności publicznej i sektorze mieszkalnym. Jednym z wymogów budownictwa zrównoważonego jest ograniczenie kosztów zużycia energii, minimalizacja powstawania odpadów, poprawa samopoczucia użytkowników oraz tworzenie zielonej przestrzeni. Najważniejsze systemy certyfikacji zielonych/ ekologicznych budynków takie jak LEED czy BREEAM obejmują również ocenę środowiska wewnętrznego w zakresie jakości powietrza, poziomu hałasu, akustyki budynku i jego energochłonności. Tradycyjne systemy uzdatniania i oczyszczania powietrza wymagają wykorzystania licznych urządzeń, systemów przesyłu powietrza świeżego i zużytego, które są energochłonne. Konieczne jest ich okresowe czyszczenie lub wymiana elementów roboczych. Alternatywą są instalacje biofiliczne (zielone ściany) oparte na naturalnych właściwościach roślin do usuwania z powietrza zanieczyszczeń gazowych, pyłów a nawet bioaerozoli. Rośliny poprawiają wilgotność, regulują stężenie dwutlenku węgla, jonizują powietrze i tłumią hałas. Natomiast procesy fotokatalitycznej degradacji związków gazowych są bardzo obiecującą metodą usuwania zanieczyszczeń, ze względu na niewielkie koszty, łagodne warunki prowadzenia procesów (temperatura i ciśnienie) i możliwość całkowitej mineralizacji zanieczyszczeń.