Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A laboratory-made porous-layer activated charcoal coated fused silica fiber was used as a microsolid phase in headspace solid phase microextraction coupled with gas chromato-graphy-mass spectrometry for identification of volatile organic compounds emitted by Zataria nmltiflora Boiss cultivated in Iran. The effect of different parameters, such as desorp-tion time, extraction temperature, sample mass, and extraction time on extraction efficiency was studied. The optimized conditions were: desorption time 2 min; extraction temperature 25°C; sample mass 0.200 g; extraction time 25 min. The main identified volatile components were: thymol (33.6%), carvacrol (17.0%), p-cymene (11.7%), linalool (5.0%), caryophyllene (2.9%), and a-terpineol (1.2%). These compounds were identified based on their retention indices and mass spectra (El, 70 eV). The proposed method for the analysis of volatile components emitted by Z. nmltiflora was very simple, fast, low-cost, and did not involve any organic solvents. The total analysis time including extraction and GC analysis was only 1 h, and no manipulation of the sample was required. Precision of the proposed method was good and RSD was less than 15%.
PL
Włókno krzemionkowe, samodzielnie pokryte węglem aktywnym, zastosowano do mikroeks-trakcji połączonej z chromatograf! ą gazową sprzężoną ze spektrometrią mas w celu identyfikacji lotnych związków organicznych, wydzielanych przez Zataria multiflora Boiss, uprawianą w Iranie. Badano wpływ na wydajność ekstrakcji różnych parametrów, takich jak: czas desorpcji, temperatura ekstrakcji, masa próbki i czas ekstrakcji. Optymalne warunki były następujące: czas desorpcji 2 min., temperatura ekstrakcji 25°C, masa próbki 0,200 g, czas ekstrakcji 25 min. Głównymi zidentyfikowanymi lotnymi związkami były: tymol (33,6%), karwakrol (17,0%), p-cymen(l 1,7%), linalol (5,0%), kariofilen (2,9%) i a-terpi-neol (l ,2%). Te związki zidentyfikowano na podstawie ich indeksów retencji i widm masowych (El, 70 eV). Zaproponowana metoda analizy lotnych związków wydzielanych przez Z. multiflora jest bardzo prosta, szybka, tania i nie wymaga stosowania żadnych rozpuszczalników organicznych. Całkowity czas analizy, uwzględniając ekstrakcję i analizę za pomocą chromatografii gazowej wynosił tylko l godzinę. Nie było potrzebne przygotowanie próbki. Precyzja proponowanej metody jest dobra i względne odchylenie standardowe wynosiło 15%.
EN
Copper(Il) was determined spectrophotometrically as a complex with 4-benzylpiperidine-ditiocarbamate (4-BPDC). Prior to determination, the anaKte was preconcetitrated applying cloud point extraction with Triton X-114 as a surfactant. Chemical conditions influencing sensitivity ofextractive-spectrophotometric procedure were optimized. Molar absorptivity of Cu-(4-BPDC), complex was determined as 2.75x 10 L mol-1 cm-1 at λmax=435nm.Under optimum conditions (pH = 6.0, 3.0 x 10 mol L-1 4-BPDC. 0.2 % (m/v) Triton X-l14. 50°C equilibrium temperature) calibration plot was constructed and found linear in the analyte's concentration range 5-200 ng mL-1: the corresponding detection limit was 1.6 ng niL-1. In the presence of foreign ions no significant interference was observed. Precision (% RSD) of ten replicate determinations of 50.0 ng mL-1Cu(ll) was better than 2.8%.The proposed procedure was successfully applied to the determination of Cu(Il) in natural water samples.
PL
Opracowano spektrofotometryczną metodę oznaczania miedzi(Il) w postaci kompleksu z 4-benzylopipery dynoditiokarbarninianem (4-BPDC). Przed oznaczeniem analit zależano stosując ekstrakcje w punkcie zmętnienia oraz Triton X-114 jako środek pov\ ierzchniowo czynny. Zoptymalizowano warunki wpływające na czułość ekstrakcyjno-spektro foto metrycznej procedury. Molowy współczynnik absorpcji kompleksu: Cu-(4-BPDC}, wynosił 2.75x 10 L mol-1 cm-1 at λmax=435nm. W optymalnych warunkach (pH = 6.0, 3.0 x 10 mol L-1 4-BPDC. 0.2 % (m/v) Triton X-l 14; temperatura 50°C) przebieg krzywej kalibracji był liniowy w zakresie stężenia analitu od 5 do 200 ng mL-1 granicawykrywalności wynosiła 1.6 ng mL-1 nie zaobserwowano znaczącego wpływu obcych jonów. Precyzja (% RSD) obliczona na podstawie 10-u oznaczeń Cu(II) o stężeniu 50 ng L-1 nie przekraczała 2.8%. Opracowaną metodę z powodzeniem zastosowano do oznaczania Cu(II) wód naturalnych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.