Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A hybrid energy system (HES) including hydrogen fuel cell systems (FCS) and a lithium-ion (Li-ion) battery energy storage system (ESS) is established for hydrogen fuel cell ships to follow fast load transients. An energy management strategy (EMS) with hierarchical control is presented to achieve proper distribution of load power and enhance system stability. In the high-control loop, a power distribution mechanism based on a particle swarm optimization algorithm (PSO) with an equivalent consumption minimization strategy (ECMS) is proposed. In the low-level control loop, an adaptive fuzzy PID controller is developed, which can quickly restore the system to a stable state by adjusting the PID parameters in real time. Compared with the rule-based EMS, hydrogen consumption is reduced by 5.319%, and the stability of the power system is significantly improved. In addition, the ESS degradation model is developed to assess its state of health (SOH). The ESS capacity loss is reduced by 2% and the daily operating cost of the ship is reduced by 1.7% compared with the PSO-ECMS without considering the ESS degradation.
EN
Inclined web box girders are widely used in urban areas because of their attractive appearance. However, there are few studies on the vehicle shear force distribution of this type of bridge. In this study, we established 62 three-dimensional finite element models in which the shear force of each web of the box girder can be extracted; furthermore, we investigated the shear force distribution law in webs of the box girder under live loads, including single-chamber and multichamber inclined web box girders. The main parameters studied include the number of vehicle lanes and chambers, slope of the inclined webs, and support conditions. The results reveal that an uneven distribution of web shear force exists in both the single-chamber box girder and multichamber girder under live loads, and the maximum value of the vehicle shear force distribution factor is greater than the average shear value shared by all webs. Therefore, the uneven distribution of shear force in the webs of the box girder cannot be ignored under eccentric vehicle loads. These values greatly exceed the safety factor of 1.15 that is used in conventional calculations.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.