Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 1

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A sensitive and accurate LC-MS/MS method was developed and validated for the simultaneous quantification of rivaroxaban (RIV) and sitagliptin (SIT) in rat plasma using apixaban as internal standard (IS). An Agilent Eclipse plus C18 column (2.1 × 100 mm, 3.5 µm, Agilent) was used for chromatographic separation with isocratic elution. Multiple reaction monitoring (MRM) using positive-ion ESI mode to monitor ion transitions of m/z 436.8→144.9 for RIV, m/z 407.7→173.8 for SIT, m/z 459.8→442.8 for IS. The procedure of method validation included selectivity, linearity, precision, accuracy, matrix effect, extraction recovery and stability were conducted according to the guidelines of EMA and FDA. The results indicated that no obvious drug-drug interactions occurred might be owing to their differences in metabolic pathways.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.