The impact of harmonic distortions on power grids is a major issue in contemporary power networks as a result of the extensive application of non-linear loads. The purpose of this article is to explore the problem of harmonic distortion in power grids and its impact on the elements of the power grid, such as cable lines and transformers. The Schaffner PQS software product was used in this study to model power grids. New techniques for modeling power grids and finding technical solutions that meet the IEEE 519-2014 standard were introduced. The study finds that harmonic distortion can lead to an additional heat load being placed on cable lines and reduces the power available to transformers, which can decrease their rated power. The application of modern software reduces the time and complexity of calculations, and the availability of software solutions for limiting harmonic distortion simplifies the creation of solutions that meet this standard. Using the methods presented in the study, engineering solutions can be improved, the reliability of electrical systems can be increased, and the loss of electrical energy can be reduced. This can enhance efficiency for design engineers and technical specialists involved in the operation of power grids.
PL
Wpływ zniekształceń harmonicznych na sieci elektroenergetyczne jest ważnym zagadnieniem we współczesnych sieciach elektroenergetycznych w wyniku szerokiego zastosowania obciążeń nieliniowych. Celem niniejszego artykułu jest jest zbadanie problemu zniekształceń harmonicznych w sieciach elektroenergetycznych i ich wpływu na elementy sieci, takie jak linie kablowe i transformatory. Do modelowania sieci elektroenergetycznych wykorzystano oprogramowanie Schaffner PQS. Przedstawiono nowe techniki modelowania sieci elektroenergetycznych i znajdowania rozwiązań technicznych zgodnych ze standardem IEEE 519-2014. Badanie wykazało, że zniekształcenia harmoniczne mogą prowadzić do dodatkowego obciążenia cieplnego linii kablowych i zmniejszać moc dostępną dla transformatorów, co może zmniejszać ich wydajność. Zastosowanie nowoczesnego oprogramowania zmniejsza czas i złożoność obliczeń, a dostępność rozwiązań programowych do ograniczania zniekształceń harmonicznych upraszcza tworzenie rozwiązań spełniających tę normę. Korzystając z metod przedstawionych w badaniu, można ulepszyć rozwiązania inżynieryjne, zwiększyć niezawodność systemów elektrycznych i zmniejszyć straty energii elektrycznej. Może to poprawić efektywność pracy inżynierów-projektantów i specjalistów technicznych zaangażowanych w eksploatację sieci elektroenergetycznych.
EN
The analysis of factors and approaches to the conditioning of the electromagnetic impact of 330 kV overhead transmission lines on ecological systems has been carried out. The analysis performed enabled to reveal that the world experience, recording the introduction of the transmission lines of the carrying capacity and reduced environmental impact, including the compact and controlled self-compensating lines, is expedient to take into consideration in the process of the object design, as compared with the transmission line of the conventional construction, operated in Ukraine. The technique of electromagnetic field of the 330 kV overhead transmission lines calculation is improved for the ecological systems and to clarify the width of the sanitary protection zone. Unlike other technique, the given one takes into account the line clearance and the sag of, also this technique is universal as it enables to calculate and analyze the variation of the electromagnetic field of the overhead transmission lines of different construction not only on the line route, but also at a distance from it.
PL
Przeprowadzono analizę czynników i podejść do uwarunkowań oddziaływania elektromagnetycznego napowietrznych linii przesyłowych 330 kV na systemy ekologiczne. Analiza pozwoliła stwierdzić, że doświadczenia światowe, odnotowujące wprowadzenie linii przesyłowych o większej nośności i mniejszym oddziaływaniu na środowisko, w tym linii kompaktowych i sterowanych samokompensujących, są celowe do uwzględnienia w procesie projektowania obiektu, w porównaniu z linią przesyłową o konstrukcji konwencjonalnej, eksploatowaną na Ukrainie. Technika obliczania pola elektromagnetycznego napowietrznych linii przesyłowych 330 kV została udoskonalona pod kątem systemów ekologicznych oraz w celu uściślenia szerokości strefy ochrony sanitarnej. W odróżnieniu od innych technik, ta uwzględnia prześwit i zwis linii, a także jest uniwersalna, gdyż umożliwia obliczanie i analizę zmienności pola elektromagnetycznego napowietrznych linii przesyłowych o różnej konstrukcji nie tylko na trasie linii, ale także w pewnej odległości od niej.