1
Content available Boosting resonant switched-capacitor voltage tripler
EN
This elaboration presents the concept of a unidirectional DC–DC switchedcapacitor converter operating as a voltage tripler. The system consists of two resonant cells with switched capacitors and chokes. This proposed converter topology achieves low voltages on semiconductor switches (diodes and transistors) compared to the classic SC series-parallel converter or the boost topology. The output voltage on the capacitors is reduced in the proposed converter because it is divided into two series-connected capacitors with asymmetric distribution. The presented results describe the analytical description of the system operation and the analytical equation for semiconductor currents. A simulation and experimental results have been performed. The system efficiency and three voltage gain values were measured in the experimental setup. The efficiency measured was also compared with the analytical determination curve for loss analysis and further converter optimization.
EN
This paper proposes a transformerless dual half-bridge converter (TLDAHB). By eliminating the transformer and harnessing the possibility of using a low inductor value, it is possible to minimise the size of the converter. A phase-shift pulse width modulation will result in a wide controlled voltage gain of the converter and operation as buck and boost. The theoretical topology analysis, simulation, and experimental results are presented. Theoretical analysis consists of analysis of power transfer and design. In case of experimental research, particular attention was paid to power transfer and efficiency analysis. Near zero switching transient of voltage in the half-bridge topology results with high efficiency.
PL
W artykule przedstawiono jednofazowy filtr aktywny z zasobnikiem energii dwukierunkowym przekształtnikiem DC/DC, dedykowanym do kompensacji udarów mocy czynnej generowanych przez nieliniowe obciążenia o pracy przerywanej. Jako obiekt kompensacji użyto jednofazową zgrzewarkę punktową. Praca zawiera kompleksową analizę pracy urządzenia, która umożliwiła opracowanie aparatu matematycznego wykorzystanego do wymiarowania zasobnika. Wysoką skuteczność rozwiązania potwierdzono w wyniku badań symulacyjnych oraz eksperymentalnych na zrealizowanym modelu laboratoryjny urządzenia. W części 1 artykułu przedstawiono zasadę działania, wyniki analiz teoretycznych oraz dobór podstawowych parametrów w układu.
EN
This paper presents a single-phase power filter with an energy storage bidirectional DC/DC converter. The device is dedicated to the compensation of active power surges generated by nonlinear loads characterized by intermittent operation. As a compensated and filtered object, the single-phase spot welding machine was assumed. The work contains a comprehensive analysis of the device's operation, which enabled the development of storage sizing methodology. The high efficiency of the solution was confirmed during simulation and experimental approach, on especially developed laboratory model. Part 1 of the article presents the principle of operation, results of theoretical analyzes and the selection of basic parameters in the system.
PL
W artykule przedstawiono jednofazowy filtr aktywny z zasobnikiem energii dwukierunkowym przekształtnikiem DC/DC, dedykowanym do kompensacji udarów mocy czynnej generowanych przez nieliniowe obciążenia o pracy przerywanej. Jako obiekt kompensacji użyto jednofazową zgrzewarkę punktową. Praca zawiera kompleksową analizę pracy urządzenia, która umożliwiła opracowanie aparatu matematycznego wykorzystanego do wymiarowania zasobnika. Wysoką skuteczność rozwiązania potwierdzono w wyniku badań symulacyjnych oraz eksperymentalnych na zrealizowanym modelu laboratoryjny urządzenia. W części 2 artykułu przedstawiono wyniki badań symulacyjnych, oraz rezultaty eksperymentu.
EN
This paper presents a single-phase power filter with an energy storage bidirectional DC/DC converter. The device is dedicated to the compensation of active power surges generated by nonlinear loads characterized by intermittent operation. As a compensated and filtered object, the single-phase spot welding machine was assumed. The work contains a comprehensive analysis of the device's operation, which enabled the development of storage sizing methodology. The high efficiency of the solution was confirmed during simulation and experimental approach, on especially developed laboratory model. Part 2 of the article presents the results of simulation studies and the results of the experiment.
EN
The article presents a modulation method for BLDC motors with unconnected windings. This method uses two full bridges (or three 12-switch H-bridges). The useof the described modulation enables reducing the motor current variable and increasing (fourfold in relation to the switching frequency) the motor current ripple frequency. Themost important benefit of using a 12-switch inverter is the twofold reduction of the dc-linkvoltage while maintaining the rated rpm (voltage reduction in comparison to a typical supplymethod). A voltage reduction causes a reduction in losses on semi-conductor elements. Thearticle also demonstrates that the proposed modulation technique significantly shortens thetime of current commutation between windings.
6
Content available remote Pojemności pasożytnicze w układach energoelektronicznych
PL
Artykuł prezentuje metody wyznaczenia pojemności pasożytniczej w układzie zawierającym tranzystory MOSFET oraz dławik lub transformator. Metody zostały opisane, przeprowadzono symulację komputerową oraz zaprezentowano wyniki doświadczeń laboratoryjnych w celu potwierdzenia ich słuszności.
EN
The article presents methods for determining parasitic capacitance in a power electronics system containing MOSFET transistors and transformer or choke inductance. The methods were described in details and computer simulations were carried out. The results of laboratory experiments were presented to confirm their validity.
PL
Celem artykułu jest przedstawienie metody sterowania maszyny PMSM, która będzie wykorzystywała sposób sterowania, charakterystyczny dla silnika BLDC. Zostały wykonane badania symulacyjne i modele silnika synchronicznego o magnesach trwałych w programie Matlab/Simulink. Zaproponowana metoda została opisana oraz przeprowadzono symulacje w celu przetestowania zaproponowanego rozwiązania.
EN
The purpose of this paper is to present a method for the control of PMSM with classic BLDC commutation approach. The PMSM motor model was developed. A novel control method was presented and a test was carried out to determine the correctness of new approach in a simulation manner.mo.
PL
W artykule przedstawiono koncepcję filtru aktywnego z zasobnikiem energii przystosowanego do kompensacji chwilowych dużych obciążeń mocą czynną i bierną o nieciągłym charakterze jej poboru (np. zgrzewarek punktowych). Zadaniem układu, oprócz typowych możliwości filtracyjnych jest również realizacja ciągłości poboru energii z linii zasilającej - ograniczenie wahań mocy czynnej. Artykuł omawia algorytm sterowania układem, opracowany za pomocą programu Matlab & Simulink, który następnie automatycznie przeniesiono ze środowiska symulacyjnego na zrealizowany na potrzeby eksperymentu układ sterownika DSP. Skuteczność przeprowadzonego procesu programowania potwierdzono w wyniku testów HIL, na stanowisku symulatora czasu rzeczywistego RTS.
EN
This paper presents a novel active power filter equipped with an energy storage system. Solution can be used for compensation of singlephase, high active and reactive momentary power loads. Characterized by non-periodic power flow (e.g. spot-welders). Apart from typical filtration capabilities, the device is responsible for continuous energy flow from the mains and reduction of active power fluctuations. The article provide comprehensive description of control algorithm, developed in Matlab & Simulink environment, which was automatically transferred from the simulation model to the DSP controller - especially developed for this purpose. The effectiveness of the programming process was confirmed during HIL tests, carried out on real time simulator RTS.