Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A universal method for constructing multidimensional approximation models of surface eddy current probes with various structures of excitation systems is proposed. This method presupposes, firstly, the description of the eddy-current probe interaction with a testing object. Secondly, a computer design of the computational experiment based on quasi-random sequences with a minimum discrepancy is constructed. Thirdly, an approximation model is created using additive neural network regression and the assessment of the adequacy and information content of the obtained multivariate approximation model. The examples of approximation dependences of the eddy current density distribution are considered. Currents are generated by the uniform surface eddy current probes in the testing object. The results of reproduction of multidimensional response surfaces in the form of level lines are given. The lines were obtained on the basis of approximation models with an assessment of their quality using scatter diagrams. The value of the relative model error in the form of distribution histograms is presented.
PL
Zaproponowano uniwersalną metodę konstruowania wielowymiarowych modeli aproksymacyjnych powierzchniowych sond wiroprądowych o różnych strukturach układów wzbudzających. Metoda ta zakłada, po pierwsze, opis interakcji sondy wiroprądowej z obiektem badanym. Po drugie, konstruuje się komputerowy projekt eksperymentu obliczeniowego oparty na sekwencjach quasi-losowych o minimalnej rozbieżności. Po trzecie, tworzony jest model aproksymacyjny z wykorzystaniem addytywnej regresji sieci neuronowych oraz ocena adekwatności i zawartości informacyjnej otrzymanego wielowymiarowego modelu aproksymacyjnego. Rozważane są przykładowe zależności aproksymacyjne rozkładu gęstości prądów wirowych. Prądy generowane są przez jednolite powierzchniowe sondy wiroprądowe w badanym obiekcie. Podano wyniki odwzorowania wielowymiarowych powierzchni odpowiedzi w postaci linii poziomicowych. Linie te otrzymano na podstawie modeli aproksymacyjnych z oceną ich jakości za pomocą wykresów rozrzutu. Przedstawiono wartość błędu względnego modelu w postaci histogramów rozkładu.
2
Content available remote Acoustic excitation of electric field in water solution NaCl
EN
The electric field value has been measured in an electroconducting water solution with NaCl, arising at simultaneously action on it of ultrasound and a direct magnetic field. Basic approaches and scheme of the laboratory device are proposed and designed. The basic characteristics of ultrasonic radiation in a place of measurement of electric field are defined, proceeding from its value and the experimental installation parameters. It is possible to assume, that at constant values of intensity of radiation and a magnetic field the value of measured voltage in the set areas of a body will give the new quantitative information on an organism state. Possibility of use of measurements of electric field for studying of properties of the biological tissue is discussed.
PL
Wartość pola elektrycznego została zmierzona w elektroprzewodzącym roztworze wodnym z NaCl, powstającym przy równoczesnym oddziaływaniu na nie ultradźwiękami i bezpośrednim polem magnetycznym. Zaproponowano i zaprojektowano podstawowe podejścia i schemat urządzenia laboratoryjnego. Określono podstawowe właściwości promieniowania ultradźwiękowego w miejscu pomiaru pola elektrycznego, wychodząc z jego wartości i eksperymentalnych parametrów instalacji. Można założyć, że przy stałych wartościach natężenia promieniowania i pola magnetycznego wartość mierzonego napięcia w zadanych obszarach ciała da nową informację ilościową o stanie organizmu. Omówiono możliwości wykorzystania pomiarów pola elektrycznego do badania właściwości tkanki biologicznej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.