The paper presents the results related to the simulation of dust-separating tangential cyclones: single cyclones of various geometries, and an axial multi-cyclone with fixed geometries and components. Its goal was to apply low-cost analyses for cyclones in industrial realization. Therefore, the presented research was applied with simulation methodology as a problem of Computational Fluid Dynamics. The models were analyzed using SolidWorks Flow Simulation software. The presented dust collectors are real-life objects, applied in industrial facilities. For a multi-cyclone, the increase in the number of blades, from 5 to 8, together with the change in the angle of a blade’s pitch i.e., 30° and 45°, resulted in dust concentration along the internal walls from just 10% for 5 blades up to c.a. 37.5% for 6 blades, and c.a. 50% for 8 blades, whereas the dust concentration in the device’s central part equals c.a. 20% for the last option. The model validation draws attention to the potential applicability of the software in flow issues alongside common and more complex numerical environments.
The paper presents statistical analysis of measurement results of electrical parameters for photovoltaic modules installed in stationary and dual-axis configurations. The parameters which were taken into account included: coefficient of variation, skewness and standard deviation. Also a correlation was determined between independent variables such as insolation, sunshine duration, cloudiness, ambient temperature and atmospheric pressure, and the dependent variable in the form of the daily electricity from photovoltaic conversion. In order to determine the repeatability of electricity waveforms occurring between summer months as well as between summer and winter months, the non-parametric U Mann-Whitney test was used. In order to analyse the repeatability of daily peak hours in which the highest value of the hourly electricity production is observed, the non-parametric Kruskal-Wallis test was used. The tested systems were connected to the power grid and operated independently. Test stands consisting of polycrystalline photovoltaic modules, single-phase on-grid inverters, irradiance sensors and a temperature recorder, were located on the building rooftop of the Faculty of Control Robotics and Electrical Engineering of the Poznan University of Technology in Poland (Central Poland, 52°24.4152′N, 16°55.7958′E) at the height of 30 metres above the ground level. A significant increase in the production of electricity using the PV module spatial positioning system was demonstrated in relation to modules based on the year-round modified design.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W pracy włączono sie w powszechnie prowadzone rozważania dotyczące ekologicznych aspektów wytwarzania energii elektrycznej. Bardziej szczegółowo zajęto sie wydajnością energetyczną turbin wiatrowych, przy czym skupiono się głównie na turbinach wiatrowych małej mocy o pionowej osi obrotu. Analizy przeprowadzono dla lokalizacji systemu w mieście Poznań. W końcowej części porównano własności użytkowe turbin o pionowej osi obrotu (VAWT) z powszechnie stosowanymi turbinami o poziomej osi obrotu (HAWT).
EN
The study joins the commonly conducted considerations regarding ecological aspects of electricity generation. The energy efficiency of wind turbines was analyzed in details, with a focus on low power wind turbines with a vertical axis of rotation. The analyzes were carried out for the system located in the city of Poznań. Finally, the performance characteristics of vertical rotation axis wind turbines (VAWT) were compared with commonly used horizontal axis wind turbines (HAWT).
W pracy przedstawiono koncepcję stanowiska dydaktycznego do badania czujników położeń liniowych i kątowych, działających na zasadzie efektu Halla. Opisano krótko teoretycznie funkcjonowanie czujników przemieszczeń i położeń liniowych oraz kątowych, szczególną uwagę skupiając na czujnikach Halla. Zamieszczono rozważania dotyczące oczekiwań i funkcji spełnianych przez budowane dydaktyczne stanowiska badawcze. Głównym członem pracy jest przedstawienie opracowanego i zbudowanego stanowiska laboratoryjnego do badania czujników położeń liniowych i kątowych. Zamieszczono założenia projektowe, związane z wymaganiami stawianymi dydaktycznym obiektom badawczym. Opisano projekt stanowiska badawczego, jego realizację oraz własności funkcjonalne. Przedstawiono także i skomentowano przykładowe badania przeprowadzone na wykonanym stanowisku pomiarowym.
EN
The work presents the concept of a teaching stand for testing linear and angular position sensors operating on the basis of the Hall effect. Theoretically, the functioning of sensors measuring linear and angular position and displacement has been briefly described, focusing on Hall sensors. Considerations were given regarding expectations and functions fulfilled by the didactic research posts being built.. However, the main part of the work is to present a developed and constructed laboratory stand for testing linear and angular position sensors. Design assumptions related to the requirements for didactic research facilities were included. The design of the test stand, its implementation and functional properties are described. Exemplary tests carried out on the completed test stand were also presented and commented on.
W artykule przedstawiono propozycje oryginalnych stanowisk do badań i prezentacji funkcjonowania czujników prędkości obrotowej oraz położeń liniowych i kątowych. Celem opracowania i wykonania tych stanowisk jest ich wykorzystanie w działaniach dydaktycznych jako elementów ćwiczeń laboratoryjnych, związanych z układami elektrycznymi i informatycznymi stosowanymi w przemyśle i w pojazdach. Z tych względów zajęto się również dydaktycznymi oraz technicznymi aspektami doboru i organizacji środków przekazu informacji w procesach kształcenia. Skupiono się na opracowaniu stanowisk badawczych w taki sposób, aby umożliwiały zdobywanie umiejętności praktycznych oraz zrozumienie teoretycznych aspektów przekazywanej wiedzy w zakresie rozważanych zagadnień. W pracy opisano konstrukcje zaprojektowanych i zrealizowanych stanowisk badawczych, sposoby ich wykonania oraz możliwości zastosowań.
EN
The article presents original stations for testing and presenting the functioning of rotational speed as well as linear and angular positions sensors. The purpose of the development and implementation of these stands is their use in didactic activities as elements of laboratory exercises related to electrical and IT systems used in industry and vehicles. For these reasons, didactic and technical aspects of the information selection and organization in educational processes were considered. The aim was to develop a stands that allow to obtain practical skills and understand the theoretical aspects. The work describes the construction of designed and realized research stands, the ways of their implementation and the possibilities of applications.
W pracy dokonano analizy poprawności funkcjonowania instalacji fotowoltaicznej o znamionowej mocy elektrycznej 3500 W, składającej się z 14 modułów fotowoltaicznych oraz przetwornika energoelektronicznego w postaci jednofazowego falownika napięcia, wyposażonego w układ śledzenia punktu mocy maksymalnej, w przypadku wystąpienia udarowego zakłócenia elektromagnetycznego typu surge. Udar napięciowy o parametrach 1,2/50 μs, symulujący wyładowanie piorunowe, został wprowadzony do układu od strony sieci elektroenergetycznej. W celu komputerowego odwzorowania sygnału zaburzającego wykorzystano zalecenia zawarte w normie PN-EN 61000-4-5 „badanie odporności na udary typu surge”. Wykazano istotne zmiany wartości napięcia elektrycznego po stronie stałoprądowej, związanej z układem generacji mocy elektrycznej przez układ fotowoltaiczny, oraz zmiennoprądowej w układzie przemiennika DC/AC.
EN
The work analyzes the correctness of the photovoltaic system operation with a nominal electrical power of 3500 W, consisting of 14 solar modules and a power electronics transducer in the form of a single-phase voltage inverter equipped with a maximum power point tracking system, in the case of a surge electromagnetic interference. The voltage surge with the parameters 1.2/50 μs, simulating a lightning discharge, was introduced into the system from the power grid side. For the purpose of computer imaging of the disturbing signal, the recommendations included in the PN-EN 61000-4-5 standard "Surge Resistance Test" were used. Significant changes in the voltage value on the DC side, related to the system of electric power generation by the solar system, and AC current in the DC/AC converter system have been shown.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.