Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The purpose of this study was to generate more concise rule extraction from the Recursive- Rule Extraction (Re-RX) algorithm by replacing the C4.5 program currently employed in Re-RX with the J48graft algorithm. Experiments were subsequently conducted to determine rules for six different two-class mixed datasets having discrete and continuous attributes and to compare the resulting accuracy, comprehensibility and conciseness. When working with the CARD1, CARD2, CARD3, German, Bene1 and Bene2 datasets, Re-RX with J48graft provided more concise rules than the original Re-RX algorithm. The use of Re-RX with J48graft resulted in 43.2%, 37% and 21% reductions in rules in the case of the German, Bene1 and Bene2 datasets compared to Re-RX. Furthermore, the Re-RX with J48graft showed 8.87% better accuracy than the Re-RX algorithm for the German dataset. These results confirm that the application of Re-RX in conjunction with J48graft has the capacity to facilitate migration from existing data systems toward new concise analytic systems and Big Data.
EN
This paper proposes an asymmetric acceleration drive method for linear oscillatory actuators under open-loop control. The effectiveness of this method is confirmed through the comparison of the 3-D FEM analysis results with the measurements of a prototype.
PL
W artykule przedstawiono asymetryczne urządzenie oscylacyjne dla liniowych aktuatorów ze sterowaniem otwarto-pętlowym. Efektywność metody analizy została potwierdzona poprzez porównanie analizy elementowo-skończeniowej z wynikami pomiarów3D.
EN
Covalent affinity chromatography with thiol-disulphide interchange (CAC-- TDI) on Sepharose-DTNB gel was employed for separation of Cu-thionein (Cu-Th) from the łivers of Cu induced white rats (3.0 mg of Cu per kg body weight, administered subcutaneously in physiological saline). Cu-thionein was prepared by gel permeation chro-matography (GPC) on Sephadex G-200 geł. The metallothionein protein (MT) was fractionated by two-, three- and four-step elutions. The CU(2+) ion dissociated fi.om Cu-thionein and protein aggregated by thiol-thiol intermolecular oxidation and mercaptide bonds (oligoaggregates and polyaggregates) and intramolecular formation of disulphide and mercaptide bridges in the lightmass monomer resulted from the contact with cova-lent affinity chlomatography support, inferred from rechromatoglraphy on Sephadex G-200. The dissociated CU(2+) appeared as a light complex with DTNB in fractions about 2000-2800 Da mass.
PL
Metodę chromatografii powinowactwa kowalencyjnego z wymianą mostków disiarczkowych (CAC- TDI) na złożu Sepharose-DTND stosowano do rozdziału Cu-tioneiny (Cu- Th) z wątroby białych szczurów eksponowanych przy użyciu Cu (3.0 mg Cu na kg wagi ciała, w postaci CUSO4 podawanego podskórnie w roztworze soli fizjologicznej). Cu-tioneina była otrzymywana metodą klasycznej chromatografii żelowej (GPC) na żelu Sephadex G-200. Białko metalotioneinowe frakcjonowano przy użyciu dwu-, trój- i czterostopniowej elucji. Podczas rozdziału jony CU2+ dysocjowały z Cu-tioneiny i powstały agregaty białkowe w wyniku utleniania grup tiolowych oraz tworzenia się wiązań merkaptydowych (oligoagaty i poliagregaty). W wyniku kontaktu ze złożem do chromatografii powinowactwa kowalencyjnego powstawały także wewnątrzcząsteczkowe mostki disiarczkowe oraz merkaptydowe w monomerach o niskiej masie cząsteczkowej, co potwierdzano rechromatografując powstałe frakcje na żelu Sephadex G-200. Dysocjujące jony Cu(2+) występowały w niskocząsteczkowej frakcji, jako kompleksy z DTNB o masie w granicach 2000 --28OO Da.
EN
This paper briefly presents results concerning signal prediction of simulated eddy current testing for in-service inspection of the steam generators of pressurized water type reactor in nuclear plants. After general remarks on the application of finite elements to this problem, a finite element technique developed for this testing is described. Finally, simulated signals from cracks of different profiles are compared with experimental measurements.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.