Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents a set of diagnostics dedicated to PF-24 – new medium size – plasma focus (PF) device built and operated at the Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN). The PF-24 can operate at energy level up to 93 kJ and charging voltage up to 40 kV. Each condenser is connected with a specially designed spark gap with a very small jitter, which ensures a high efficiency and a low current rise time. The working parameters of PF-24 generator make it a suitable tool for testing new detection systems to be used in fusion research. Four types of such detection systems are presented in this article: three diagnostic systems used to measure electric quantities (Rogowski coil, magnetic probe, capacitance probe), neutron counter based on beryllium activation, fast neutron pinhole camera based on small-area BCF-12 plastic scintillation detectors and high-speed four-frame soft X-ray camera with microchannel plate.
PL
Znormalizowane metody prób kompozytowych wsporczych izolatorów stacyjnych sprowadzają się wyłącznie do obciążeń statycznych. W eksploatacji występują jednak zarówno obciążenia statyczne, jak i zmienne. Są to głównie obciążenia zginające. Obciążenia zginające powodują ugięcie izolatorów kompozytowych znacznie większe, niż izolatorów ceramicznych. Stąd konieczność wprowadzenia nieznormalizowanych wymagań w zakresie ich dopuszczalnego ugięcia i odporności na obciążenia zmienne.
EN
Standard methods for testing composite station post insulators combine static loads only. However under operation conditions these insulators are subjected to static and variable loads. These are mainly cantilever loads. Bending of composite station post insulator can be much biger than for ceramic ones. Introduction of non standard tests and requirements for evaluation of permissible bending limits and resistance to variable loads for these insulators is necessary.
PL
Kompozytowe wsporcze izolatory stacyjne stosuje się w sieciach elektroenergetycznych na coraz większe prądy zwarcia. W badaniach znormalizowanych przewiduje się dla tych izolatorów tylko próby przy obciążeniu statycznym. Podczas przepływu prądów zwarcia na izolatory wsporcze oddziałują także zmienne siły zginające o dużych wartościach, zwykle o charakterze cyklicznym wahadłowym. W Instytucie Energetyki rozpoczęto prace nad wytrzymałością kompozytowych izolatorów wsporczych przy takich właśnie obciążeniach. Wstępny etap badań obejmował izolatory do sieci 110 kV. Wyznaczono charakterystyki zmęczeniowe i oszacowano wytrzymałość izolatorów przy obciążeniu zmiennym.
EN
Composite station post insulators are applied to electrical power grid where high surge currents can be periodically expected. Standard tests for these insulators base on application of static mechanical loads only while the composite station post insulators are subjected to variable cantilever forces of symmetrical cyclic character and high values being a result of impact of surge currents flow in to the grid. This type of variable loads has been applied to research works on mechanical strength of the insulators at the Institute of Power Engineering (IEn). Preliminary tests have been carried out for the insulators applied to 110 kV electrical power network. The fatigue characteristics are determined for these insulators to evaluate their mechanical strength at the variable loads.
PL
Wsporcze izolatory stacyjne są narażone głównie na obciążenia zginające. Przy dużych prądach zwarcia zmienne siły zginające izolator mogą osiągać wartości przekraczające znamionową wytrzymałość izolatorów. Rozpoczęte w Instytucie Energetyki prace nad wytrzymałością izolatorów wsporczych przy cyklicznym obciążeniu zginającym powinny pozwolić na sformułowanie kryterium doboru kompozytowych izolatorów wsporczych do pracy w warunkach narażenia na obciążenia zmienne, a także na przyjęcie odpowiednich wymagań dla tego rodzaju izolatorów.
EN
Station post insulators are mainly subjected to cantilever loads. At high values of short-circuit currents the dynamic cantilever loads can reach values higher than specified cantilever loads. At the Institute of Power Engineering (IEn) has been recently taken up research works on mechanical strength of composite station post insulators subjected to cyclic cantilever loads.
PL
Cyfrowe modele skał były wynikiem analizy składu mineralnego, struktury, tekstury, objętości i typu mediów wypełniających przestrzeń porową na podstawie wyników badań laboratoryjnych oraz kompleksowej interpretacji profilowań geofizyki otworowej. Wykorzystano piaskowcowo-iłowcowe utwory sarmatu z obszaru zapadliska przedkarpackiego. Badania tomograficzne na próbkach skał wykonano z użyciem prototypowego układu pomiarowego wykorzystującego technikę mikrotomografii komputerowej, zbudowanego w IFJ PAN. Dane o wykształceniu struktury skały stały się podstawą do oceny możliwości ruchu mediów porowych i wyliczenia przepuszczalności fizycznej. Porozymetria rtęciowa dostarczyła: objętość i rozkład średnic porów oraz wielkość powierzchni właściwej przestrzeni porowej. Spektrometryczne pomiary z wykorzystaniem zjawiska magnetycznego rezonansu jądrowego umożliwiły podział porów na części zajęte przez media swobodne, wodę w porach kapilarnych i związaną w minerałach ilastych. Skład mineralny skał wyznaczono na podstawie wyników kompleksowej interpretacji profilowań geofizyki otworowej oraz analizy rentgenowskiej próbek. Relacje między parametrami petrofizycznymi z pomiarów wykonanych w różnej skali (mikro- w laboratorium i makro- in situ) stanowiły podstawę do konstrukcji modeli skał.
EN
Digital rock models were built on the results of mineral composition analysis, rock structure and texture and volume and type of the medium studies on the basis of laboratory measurements and the comprehensive well logs interpretation. Sarmatian sandy-shaly formation from the Carpathian Foredeep was used in study as gas reservoir rock. Modern microtomographic measurements on the core samples were carried out using prototype laboratory-source-based facility for the computed microtomography, constructed at the IFJ PAN. High resolution structural data about matrix and porous space were the base for estimation of pore medium flow and calculation of physical permeability. Mercury porosimetry provided with data about pore volume and distribution of pore diameters and pore specific surface area. Spectrometry of nuclear magnetic resonance measurements enabled the division of media in pores into free fluid, water in capillary pores and water bounded in clay minerals. Mineral composition was determined on the basis of the comprehensive well logs interpretation and roentgen analysis. Mutual relationships between petrophysical parameters from measurements made in different scale (micro- in the laboratory and macro- in situ) were the basis for rock models construction.
6
PL
Podczas niszczenia próbki materiału część dostarczonej energii zostaje zużyta na utworzenie powierzchni przełamu. Sprawdzono hipotezę, czy kształt powierzchni przełamu materiału ceramicznego zawiera informację o materiale i sposobie jego zniszczenia. W tym celu wyznaczano wymiar fraktalny powierzchni przełamu. Do badań przeznaczono specjalnie przygotowane kształtki z różnych tworzyw ceramicznych. Charakterystyki fraktalne przełamów elementów ceramicznych wyznaczano metodą stosowaną w badaniach metali. Otrzymane rezultaty nie potwierdziły hipotezy, że wymiar fraktalny przełamu charakteryzuje warunki obciążania badanych próbek.
EN
Under process of failure of material sample a part of energy delivered to the sample is used to shape a surface of fracture. A hypothesis is assumed that from a shape of ceramic material fracture same information regarding the material an a method of its failure can be obtained. To this purpose fractal dimensions for investigated fracture surfaces were determined. The investigations were conducted using samples made of different ceramic materials. Methods applied to metals were used for calculation of fractals of the ceramic samples fractures. On the basis of the obtained results one can conclude that the hypothesis was not confirmed.
7
Content available remote Badania izolatorów kompozytowych stromo narastającymi udarami napięciowymi
PL
W artykule przedstawiono wyniki badań nad metodą i parametrami prób izolatorów kompozytowych stromo narastającymi udarami napięciowymi, zgodnie z normą PN-IEC 61109. Słuszność doboru parametrów udaru potwierdzono w badaniach izolatorów kompozytowych po długotrwałych próbach zmęczeniowych mechanicznym obciążeniem cyklicznym.
EN
The results of investigations on the method and parameters of the tests of composite insulators subjected to steep-front impulse voltage according to the standard PN-IEC 61109 were introduced in the article. Rightness of the selection of impulse voltage parameters was confirmed during investigations of insulators after long-lasting mechanical cyclic loads.
PL
Izolatory w liniach elektroenergetycznych są narażone w czasie eksploatacji na naprężenia mechaniczne zarówno stałe, jak i zmienne (cykliczne). Źródłem obciążeń cyklicznych są drgania przewodów. Rozpoczęte w 2001 r. w Instytucie Energetyki prace doświadczalne miały na celu ocenę wpływu obciążeń cyklicznych na wytrzymałość izolatorów ceramicznych. Próby przeprowadzono na izolatorach typu LPZ 75/27W1 z częścią ceramiczną wykonaną z tworzywa rodzaju C130 oraz - dla porównania - z tworzywa C120. Na podstawie uzyskanych wyników badań zaproponowano kryteria doboru ceramicznych izolatorów liniowych pod względem wytrzymałości zmęczeniowej.
PL
W NKP ds. Izolatorów systematycznie zmierza się do zapewnienia pełnej zgodności wymagań krajowych z międzynarodowymi (IEC) i europejskimi (EN). Zasadnicze trudności polegają na braku wystarczających środków finansowych. Obecnie przedstawiciel Polski bierze udział w pracach Grupy Roboczej IEC, która przygotowuje nową wersję publikacji IEC 815. W PKN trwają prace nad nowelizacją ustawy o normalizacji.
EN
Recent activity of Normalization Commission for Insulators is concentrated on ensuring the full agreement between national and international (as well as European) standards. Main problems are of financial nature. Now our representative takes part in works of the 36 WG11 Group, whose main duty is to elaborate a new version of the IEC 815 guide. Polish Normalization Communities is concentrated on elaboration of a new version of governmental normalization rule.
PL
W ostatnich latach opracowano konstrukcję izolatora hybrydowego, łączącego zalety tworzywa ceramicznego i materiałów organicznych. Izolatory takie przeznacza się do szczególnie trudnych warunków eksploatacji. Autorzy proponują konstrukcję izolatora hybrydowego z rdzeniem ceramicznym z tworzywa o znacznie większej wytrzymałości mechanicznej niż tradycyjna porcelana elektrotechniczna i z kloszami wykonanymi z elastomeru silikonowego. Przewiduje się, że izolatory te znajdują zastosowanie w trakcji elektrycznej 3 kv prądu stałego lub w aparaturze łączeniowej średniego napięcia.
EN
In order to join advantages of ceramic materials an idea of construction of hybrid insulator has been recently developed. These insulators are usually applied to extremely difficult operation conditions. In this paper, a new construction of a hybrid insulator is proposed. It consists of a ceramic rod and silicone rubber sheds. It is assumed that a ceramic material whose mechanical strength is much higher than that for traditional porcelain will be used. The insulators will be applied to DC electrical traction of 3 kv and to switchgears for middle level voltages.
PL
Celem pracy jest zbadanie wpływu porowatości pozornej porcelany na jej współczynnik stratności dielektrycznej przy uwzględnieniu napięcia, czasu działania napięcia i efektu histerezy.
EN
The porosity of ceramic material is characteristic physical property, whereas the dielectric loss factor is one of the criteria of assessment of majority insulation materials. The determination of relationship between porosity and dielectric loss factor for mentioned material is purposeful. High field strength results that the dielectric loss factor depends on material properties and thermal effect and ionisation. The voids are excellent dielectric in low field strength, but in high field strength they are serious material defects. The purpose of the presented investigation was study the relationship between dielectric loss factor, voltage, time and effect of hysteresis.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.