The paper overviews optimization based statistical design centering techniques for analog circuits. Emphasis is placed on dependence between formulation of quality indices, problem formulation, and computational complexity of design centering algorithms, executed in single- or multiple-processor environments. For characterization of solution techniques a standard CMOS op-amp design case and a simplified computational complexity analysis are used.
The paper presents novel models of resolve time for static D-latch circuits - to estimate the metastability effect more accurately, and set design margins properly. The models consider non-linearity of both the positive feedback loop and also that of initial condition setting for switching process. Accuracy advantage over the commonly used model is demonstrated with measurements and simulation of different D-latch circuits (both buffered and unbuffered ones).
PL
W artykule przedstawiono nowatorskie podejście do modelowania czasu rozdzielczego (lub rozwiązania) układów zatrzasków typu D. Stworzono nowe modele matematyczne opisujące czas rozdzielczy. Modele te pozwalają dokładniej ocenić wpływ zjawiska metastabilności na zachowanie układu przerzutnikowego. Dokładny opis zachowania metastabilnego układu przerzutnikowego (zatrzasku) pozwala na lepszy dobór parametrów projektowych. Opisane w artykule modele uwzględniają efekty nieliniowe: nieliniowość pętli dodatniego sprzężenia zwrotnego i nieliniowe ustalanie warunku początkowego. Przedstawiono wyniki eksperymentów (fizycznych i numerycznych), wskazujące na większą dokładność wprowadzonych modeli nieliniowych w odniesieniu do standardowego liniowego modelu układu przerzutnikowego.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper compares accuracy and measurement range for two techniques of multiple-sensor measurement of ion concentration in water with potentiometric ion selective sensors: a single-sensor-at-a-time measurement and multi-sensor Data Fusion based measurement. A problem of entangled measurement ranges is defined and a rational solution presented.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents accuracy analysis of CHEMFET-based characterization of ion activities in aqueous solutions. Two measurement methods are analyzed and compared: independent sensor-based and sensor array-based. Electrolyte characterization errors due to non-ideal voltage measurements, existence of interferent ions, and inaccurate sensor parameters are considered.