The paper presents the programme of research aimed at finding a recipe for high strength self-compacting and freeze-thaw resistant concrete. The programme included batching five concrete mixtures with varied W/B ratios (0.28-0.36) and various contents of GGBS relative to the mass of cement (0-30% m.c.). The influence of W/B ratio and GGBS content on the strength, water absorption and freeze-thaw resistance of concrete was analysed. Since the combined action of various factors, i.e., a simultaneous use of superplasticizer, air entraining agent and slag, can impede the achievement of the air pore structure with desired parameters, an innovative method of concrete mixture air entrainment was applied. The method involves introducing into the mixture solid particles (microspheres) with specified sizes that remain unchanged and stable over time. It follows from the results that it is possible to design and produce high strength, self-compacting and freeze-thaw resistant concrete with the use of locally available materials.
PL
W artykule przedstawiono program badań, którego celem było opracowanie receptury dla betonu wysokiej wytrzymałości charakteryzującego się samozagęszczalnością i mrozoodpornością. Program badań obejmował wykonanie pięciu betonów o zmiennym stosunku W/S (0.28-0.36) i z różną zawartością żużla w spoiwie w stosunku do masy cementu (0-30% m.c.). Analizowano wpływ stosunku W/S oraz zawartości żużla (GGBS) na wytrzymałość, nasiąkliwość i mrozoodporność betonów. Kombinacja różnych czynników, tj. jednoczesne stosowanie domieszki superplastyfikatora, napowietrzającej i żużla, często powoduje problemy z uzyskaniem pożądanych parametrów struktury porów powietrznych. Dlatego też zastosowano innowacyjną metodę napowietrzania mieszanki betonowej polegającą na wprowadzeniu stałych cząstek (mikrosfer) o określonych wymiarach, które nie zmieniają swoich wymiarów i są stabilne w czasie. Z przeprowadzonych badań wynika, że stosując lokalnie dostępne materiały, możliwe jest zaprojektowanie i wykonanie betonu o wysokiej wytrzymałości, charakteryzującego się samozagęszczalnością i odpornego na działanie mrozu.
PL
Celem badań było określenie wpływu wybranych czynników na strukturę betonu i odporność na powierzchniowe łuszczenie w obecności 3% roztworu NaCl. Badania przeprowadzono na betonach o stałym stosunku W/C = 0,45 napowietrzonych za pomocą mikrosfer polimerowych. Strukturę warstwy powierzchniowej zróżnicowano, zmieniając zawartość piasku. Dla każdej serii badaniom odporności na powierzchniowe łuszczenie poddano dwa rodzaje powierzchni: formowaną oraz uzyskaną przez przecięcie próbki sześciennej prostopadle do kierunku formowania. Badania wskazują, że zabezpieczenie betonu przed powierzchniowym łuszczeniem w obecności 3% roztworu NaCl jest dużo bardziej skomplikowane i samo, nawet poprawne napowietrzenie nie jest czynnikiem wystarczającym. Bardzo duży wpływ na wyniki badania ma rodzaj badanej powierzchni. W przypadku próbek o powierzchni ciętej uzyskano znacznie mniejsze uszkodzenia niż w przypadku naturalnej powierzchni formowanej.
EN
The focus of this study was on determining the effects of selected factors on the structure and resistance to scaling of concrete in the presence of a 3% NaCl solution. The tests were performed on concrete specimens with W/C = 0.45, air entrained with polymer microspheres. The amount of sand added was varied to provide different surface layer properties. The scaling resistance tests were performed on two surface types in each series: natural finished and sawn perpendicular to the direction of casting. As shown in the tests, it is much harder to provide efficient protection against surface scaling in the presence of the 3% NaCl solution, and air entrainment alone will be insufficient to prevent it. Scaling results are greatly influenced by test surface type. The specimens with sawn surfaces show less damage than those with natural finished surfaces.
EN
This paper deals with the issues pertinent to the design of frost-resistant concretes in exposure class XF3 (high water saturation) when the concretes are made with cements containing ground granulated blast furnace slag (ggbs). The testing programme covered four series of non-air entrained concrete made with cements CEM I, CEM II/A-S, CEM II/B-S and CEM III/A containing 0%, 13%, 28% and 53% ggbs respectively, and two non-air entrained concrete series with the binder made from CEM I and 0 to 55% ggbs. The water-binder (w/b) ratio ranged from 0.25 to 0.55. Frost durability testing was performed using a modified ASTM C666A procedure to determine changes in mass (dm) and beam length (dL). The relationships occurring between the w/b ratio and ggbs content in the binder and the length change (dL) of the specimens were described using curvilinear regression functions, through the analysis of artificial neural networks. Slag-content-dependent critical values of the w/b ratio were determined taking the length change dL = 1.3 mm to be the criterion for the resistance to internal cracking. In the authors’ view, this approach can be a good method for checking equivalent performance of concretes made with cements containing mineral additions.
EN
In this paper we discuss the test results for concretes containing various amounts of ggbs as compared to concretes made with Portland cement. The main objective of these tests is to evaluate the influence of varying air content in such mixtures on the structure and frost resistance of concrete. The authors suggest that the approach presented here allows for a safe design of concrete mixtures in terms of their frost resistance. The results indicate that concrete can be resistant to surface scaling even at the W/C ratio markedly higher than 0.45. Increased addition of ggbs leads to a decrease in concrete resistance to surface scaling. Proper air entrainment is the fundamental factor for frost-resistant concrete, and the air void system has to be assessed (micropore content A300, spacing factor L ). The addition of ggbs increases pore diameters, thus, to obtain the appropriate air pore spacing factor, micropore quantities introduced have to be increased.
PL
W artykule przedstawiono wyniki badań betonów z różną zawartością żużla w stosunku do betonów wykonanych z cementem portlandzkim. Celem badań była także ocena w jaki sposób zróżnicowana ilość powietrza w takich mieszankach (wahania ilości powietrza w mieszance) wpływa na strukturę porów powietrznych i mrozoodporność betonu. Zdaniem autorów takie podejścia pozwala na bezpieczne projektowanie betonów z punktu widzenia ich mrozoodporności.
EN
In mass production of concrete precast units, it is important to optimise technology which would ensure high early age compressive strength of concrete, and also follow the principles of sustainable manufacturing and reduce costs. The paper presents the analysis of results obtained for three series of concretes made from CEM I42.5R cement, at the water-cement ratios of 0.34, 0.38, and 0.42, cured at different temperatures, namely 20, 40 and 60°C, where heating was performed in 16-hour cycle. The analysis aimed at determining functional properties which allow the estimation of concrete compressive strength depending on the temperature history. The Carino-Lew function was adopted to determine the relation between the curing time and temperature and the equivalent curing time te. The determined values of cement thermal sensitivity factor ranged 0.023÷0.040, which was related to the w/c ratio and the strength level. An exponential function was developed to express concrete compressive strength dependence on the equivalent curing time te. In the authors’ opinion, the function can contribute to the optimisation of the production process of concrete precast units by means of designing the temperature profile, depending on the concrete mix formulation and the assumed level of concrete structural strength.
6
Content available remote Wpływ kilku czynników na wyniki normowego oznaczania nasiąkliwości betonu
PL
Przeprowadzono badania czynników wpływających na wyniki oznaczeń nasiąkliwości betonu. Uzyskane wyniki wykazały, że nasycanie wodą kostek betonowych o wymiarach 10 cm i 15 cm można zakończyć po 4 dniach. Nie stwierdzono wpływu trzech rodzajów cementów: CEM I 42,5, CEM II/B-V 32,5, CEM III/ A HSR/LH/NA. Brak wpływu stosunku w/c w zakresie 0,38, 0,44 i 0,50. Decydujący wpływ na wyniki ma czas suszenia próbek: w przypadku kostek 10 cm wynosi on 5 do 8 dni a 15 cm 6 do 11 dni, w zależności od przyjętej zmiany masy. W przypadku CEM III powinien on być dłuższy o 1 do 2 dni. Jest mniejsza nasiąkliwość kostek 15 cm od kostek 10 cm. Nasiąkliwość w przypadku zmiany masy <0,2% jest mniejsza niż <0,1%.
EN
The selected factors influence on water absorption of concrete was tested. The experimental results have shown that the water saturation of concrete cubes of 10 cm and 15 cm dimensions can be ended after 4 days. No influence of three types of cement: CEM I 42.5, CEM II/B-V 32.5, CEM III/A HSR/LH/NA. Also w/c ratio in the range 0.38, 0.44 and 0.50 has no effect. The decisive influence on the absorption results has the drying time: in the case of cubes of 10 cm it should be in the range of 5 to 8 days and 15 cm cubes between 6 and 11 days, depending on adopted mass change. In the case of CEM III it should be longer from 1 to two days. The absorption is lower in the case of 15 cm cubes, comparing to 10 cm cubes. Absorption for mass change <0.2% is lower than in the case of <0.1%.
7
Content available remote Prediction of freeze-thaw resistance of GGBFS concrete based on ANN models
EN
In the paper the neural network modelling approach was used to construct an ANNs model to investigate the influence of mix proportion on freeze–thaw GGBFS concrete internal cracking resistance. The simplest way to prevent the internal cracking due to freeze–thaw cycles is the good air-entrainment with an adequate air void spacing. The first step in developing the network was collecting the data set containing the information about mix proportion parameters, characteristics of physical structure of hardened concrete (absorption, permeability, compressive strength) and freeze–thaw durability test results obtained in laboratory using the method of polish standard PN-B-06250:1988. The collected data dealt with normal and high strength concretes made with cements: CEM I, CEM II/A,B-S and CEM III/A, air-entrained or not. The four classes of freeze–thaw durability were used in assessing the concrete resistance to internal cracking.
PL
W referacie przedstawiono rezultaty wybranych analiz wykonanych przy użyciu sztucznych sieci neuronowych aby zbadać wpływ składu betonu na jego mrozoodporność. Najprostszym sposobem zapewnienia mrozoodporności jest właściwe napowietrzenie z odpowiednim rozstawem porów powietrznych. Pierwszym etapem tworzenia sieci było zebranie informacji zawierających informację o składzie mieszanki betonowej, właściwościach fizycznych i strukturze wewnętrznej badanych betonów (absorpcja kapilarna, przepuszczalność, wytrzymałość na ściskanie) oraz przeprowadzenie testów mrozoodporności zgodnie z PN-B-06250:1988. Zebrane dane dotyczyły betonów wykonanych na cementach CEM I, CEM II/A,B-S i CEM III/A, napowietrzonych lub nienapowietrzonych. W zależności od straty wytrzymałości próbek zamrażanych metodą zwykłą PN po 150 cyklach zamrażania-rozmrażania wprowadzono pojęcie 4 klas mrozoodporności.
8
Content available remote A method of analyzing porosity structure in air-entrained concrete
EN
Important characteristics which substantially affect the system of air pores that protect concrete from cyclic freezing and thawing are the pore size distribution and number of air voids. The pore distribution is measured with the standard factor L based on the Powers model, in which considerable simplifications are assumed. The Philleo factor which determines the percentage content of protected paste located at a distance S from the edge of the nearest air void provides a better solution. Developing the concept put forward by Philleo, the PPV (paste protected volume) index was proposed. PPV is the ratio of the volume of the paste protected by air pores, at the assumption that S=200 µm, to the total paste volume. It accounts not only for sizes and number of air voids, but also for aggregate grains often disregarded in analyses. The task to determine four phases for real concrete is extremely difficult, therefore an approach in which an idealised image of concrete grain structure generated on the basis of a numerical model was used. The results obtained from image analysis were compared with standard spacing factor L and with the parameters developed by Philleo and Attiogbe. The analyses conducted by the authors shows that accounting for aggregate grains in calculations substantially affects the assessment of the quality of the air pore structure.
PL
Rozkład wielkości pustek powietrznych oraz ich ilość są ważnymi charakterystykami, które mają znaczący wpływ na system porów powietrznych zabezpieczających trwałość betonu przed cyklicznym zamrażaniem-rozmrażaniem. Charakterystyk tych nie uwzględnia normowy wskaźnik rozmieszczenia porów L określany w oparciu o model Powersa, który zakłada istotne uproszczenia. Lepszym rozwiązaniem jest np. wskaźnik Philleo, który określa procent zaczynu chronionego przez pory powietrzne, czyli znajdującego się w odległości S od najbliższej pustki powietrznej. Rozwijając koncepcję Philleo zaproponowano wskaźnik PPV, który stanowi stosunek powierzchni obszarów zaczynu chronionego przez pory powietrzne, przy założeniu S=200 µm, do całkowitej powierzchni zaczynu. Wskaźnik PPV uwzględnia nie tylko liczbę oraz rozkład wielkości porów powietrznych ale również rozkład wielkości ziaren kruszywa, co w wielu analizach jest pomijane. Ponieważ wyznaczenie czterech faz betonu jest rzeczą bardzo trudną dla rzeczywistych zgładów, postanowiono posłużyć się modelem numerycznym. Model ten umożliwia wygenerowanie struktury ziarnistej betonu napowietrzonego z uwzględnieniem założonych rozkładów wielkości porów powietrznych oraz wielkości ziaren kruszywa. Wyniki otrzymane na podstawie analizy obrazu numerycznego zostały porównane z normowym wskaźnikiem rozmieszczenia porów L oraz ze wskaźnikami Philleo i Attiogbe. Badania przeprowadzone przez autorów pokazują, że uwzględnienie obecności ziaren kruszywa w obliczeniach znacząco wpływa na ocenę jakości struktury porów powietrznych.
EN
Air void size and number distribution constitutes a major characteristic, which substantially contributes to building up concrete resistance to cyclic freezing and thawing. The standard pore spacing factor L is based on the Powers model. Due to the assumptions made in the model, it may not be able to represent the real structure of air pores in the concrete. Consequently, it is necessary to look for other methods to describe this structure. The sought model needs to account for variability in sizes of pore chords and pore random spacing in the paste. The paper analyses the distribution type and compares porosity characteristics obtained with measurements, and on the basis of the distribution. The analysis aims to assess if it is possible to substitute chords in the 0 to 400 μm range with their distribution. Another purpose of the analysis is to compare air pore structure parameters obtained by computations on raw data with the results received on the basis of pore size distribution for a given concrete.
PL
Artykuł dotyczy zagadnienia dokładności szacowania wytrzymałości na ściskanie betonu dojrzewającego w okresie zmiennych temperatur. Wyznaczono współczynniki aktywności hydraulicznej 8 różnych cementów zgodnie z wytycznymi normy ASTM C 1074. Poprawność oszacowania wytrzymałości betonu oceniono na podstawie badań 2 serii betonów dojrzewających w wodzie o temperaturze 5, 20, 35°C. Przeanalizowano 3 różne zależności wytrzymałość-dojrzałość: wytyczne ITB, funkcję Plowmana oraz funkcję Hansena-Pedersena. Najlepszą zgodność wyników obliczeniowych z wynikami doświadczalnymi uzyskano stosując funkcję dojrzałości H-P przyjmując wartość współczynnika aktywności cementu wyznaczonego wcześniej. Stosowanie innych zależności może prowadzić do dużych błędów zwłaszcza we wczesnym okresie dojrzewania betonu.
EN
The paper is devoted to the accuracy of compressive strength assessment of concrete matured at different temperatures. The indexes of hydraulic activity of 8 different cements were establish, according to ASTM C 1074 standard. The correctness evaluation of concrete strength assessment was based on experimental results obtained for two series of concretes, cured in water at 5, 20 and 35°C. Three different relation strength - maturity: instruction of Polish Institute of Building Technology, Plowman function and Hansen-Pedersen function. The best concordance of calculated data with experimental results was assured by Hansen-Pedersen maturity function, using the hydraulic activity index, obtained experimentally. The application of other functions can cause errors, especially in early period of concrete maturing.
PL
Badanie nasiąkliwości betonu, pomimo że jest oznaczeniem prostym technicznie budzi jednak dyskusje ze względu na poprawność uzyskiwanych wyników. Brak jednoznacznego opisu procedury badania powoduje, że wyniki uzyskiwane w różnych laboratoriach mogą nie być porównywalne. W referacie przedstawiono wyniki badania nasiąkliwości 5 serii betonów wykonanych z trzema różnymi cementami, o trzech różnych stosunkach W/C. Badania prowadzono na kostkach sześciennych o boku 10 i 15 cm, które były długotrwale nasycane i suszone. Z przeprowadzonych badań wynika, że decydujący wpływ na wyniki oznaczeń nasiakliwości wagowej ma wielkość badanej próbki oraz czas suszenia próbek, który znacznie przekracza minimalny czas określony w normie dla prefabrykatów betonowych.
EN
In spite of the fact that common concrete absorption tests are technically simple, the correctness of received results is still very disputable. The lack of unequivocal procedures makes it impossible to compare the results obtained in various laboratories. The paper presents the research results received in 5 series of concrete with three different cements and various w/c ratios. The investigations were conducted on cube specimens with dimensions of 10cm and 15cm, all cubes were soaked and dryed in long terms. The object of the research was to identify the effect of specimens dimensions and soaking time on the concrete absorption. Soaking time applied to investigations vastly exeeds the common soaking time described in standards concerning precast concrete elements.
EN
Current requirements for concrete mix design for bridges, including the acceptable absorption value of nw ≤ 4% are being widely discussed. This paper presents the results of the research conducted on concrete with granite aggregate content. The research involved the analysis of relationshp between strength, absorption, permeability, porosity structure and the freeze-thaw resistance of air entrained and non-air entrained concretes with variable W/C ratios.
PL
Wielu problemów związanych z brakiem powtarzalności w uzyskiwaniu analogicznej struktury porow powietrznych można uniknąć dodając do betonu stałe cząstki o określonych średnicach, puste w środku, tzw. mikrosfery. Rozwiązanie to pozwala na wprowadzenie do betonu porów powietrznych w formie mikrosfer o odpowiednich, stałych wymiarach. Badania przedstawione w niniejszym artykule miały na celu określenie zależności pomiędzy strukturą porowatości a mrozoodpornością betonów napowietrzonych za pomocą mikrosfer polimerowych. Ponadto rozważano możliwości obniżnia ogólnej zawartości powietrza poprzez zmniejszenie zawartości dużych pęcherzykow powietrznych w wyniku zastosowania domieszki przeciwspieniającej. Na podstawie przeprowadzonych badań stwierdzono, że możliwe jest zapewnienie dobrej odporności na mróz betonów z cementu hutniczego napowietrzonych poprzez dodatek mikrosfer polimerowych o średnicach 40 i 80 mikrometra. Zastosowanie mikrosfer polimerowych pozwoliło uzyskać znacznie korzystniejszą strukturę porowatości niż podany w wymaganiach technicznych wskaźnik rozstawu porów L < 0,20 mm i zawartość porów A300 > 1,5%. Możliwe jest uzyskanie dobrej mrozoodporności betonów przy całkowitej zawartości powietrza mniejszej niż 4%.
EN
Many of the problems connected with non-reproducibility of air void system can be avoided by adding hollow solid particles with given diameters, the so called microspheres. This solution helps introduce into the concrete the "air voids" in a form of microspheres of adequate, fixed size. The studies presented in this article aimed at determining the relationship between porosity structure and the resistance to frost demonstrated by concretes air entrained by means of polymer microspheres. Another issue considered here was reducing the total air content through reducing the content of large air bubbles as a result of adding the anti-foaming admixture. On the basis of the conducted investigations it has been proved that it is possible to ensure good frost resistance for concretes made with metallurgical cement and air entrained by adding polymer microspheres which are 40 and 80 micrometer in diameter. The application of polymer microspheres helped obtain much better porosity structure parameters than those specified in the technical requirements, where spacing factor L < 0,20 mm and air void content A300 > 1,5%. It is possible to achieve good concrete frost resistance with the total air content less than 4%.
PL
W referacie przedstawiono wyniki badań 9 serii betonów BWW napowietrzanych za pomocą mikrosfer polimerowych. Celem badań było okrerślenie związku pomiędzy strukturą porowatości, stosunkiem W/C i mrozoodpornością betonu.
EN
The paper present the results of examinations of 9 series of HCP air-entrained concretes made with microspheres. The aim was to estimate the relastions between air-pores structures, W/B ratio and freeze-thaw durability.
PL
W referacie przedstawiono wyniki badań 22 serii betonów różniących się rodzajem cementu, o stosunku W/C od 0,35 do 0,48 i zawartości powietrza od 1,3 do 10,1%. Celem badań było określenie zależności występujących pomiędzy charakterystykami porowatości, nasiąkliwością, wytrzymałością na ściskanie oraz trwałością mrozową betonów napowietrzonych. Stwierdzono, te do uzyskania dobrego napowietrzenia konieczne jest wprowadzenie minimum 1,6% zawartości mikropęcherzyków A3tt i/lub uzyskanie niskiej nasiąkliwości n"<4%. Uzyskanie wysokiej wytrzymałości betonu na ściskanie fc">60MPa nie stanowi wystarczającego warunku jego mrozoodporności.
EN
The paper presents the results of examinations of 22 series of concretes made with different kind of cement, W/C-0,35-0,48 and air content 1,3-10,1%. The aim was to estimate relations between air-pores characteristics, absorption, compressive strength and freeze-thaw durability of air-entrained concrete. It was stated that good air-entrainment need introduction of minimum 1,6% micro pores A300 and/or low absorption nw<4% High compressive strength fcm> 60 MPa was not sufficient criterion of F-T durability.
PL
W referacie przedstawiono analizę wpływu czynników związanych ze składem mieszanki betonowej (wskaźników WIS i WIC, ilości dodatku żużla wielkopiecowego) na właściwości stwardniałego betonu (wytrzymałość, nasiąkliwość, odporność mrozową na wewnętrzne pękanie i powierzchniowe łuszczenie) w kontekście normy PN-EN 206.
EN
The paper presents the analysis of relations between concrete mix composition (water-binder ratio, water-cement ratio, blast fumace slag content) and properties of hardened concrete ( compressive strength, absorption, resistance for intemal cracking and scaling during cyclic freezing in air and wather) in context of PN-EN 206 standard.