Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
With the analysis of the industrial economic theory structure – conduct – performance model, the study investigates the existence of significant relationship among market structure, conduct and performance. Twelve Taiwan companies are studied during the study period from 2006 to 2012 which are analysed with fixed effect and random effect of panel data and ordinary least squares estimation. The empirical result backs the statement by “Structuralism” that market structure (market share, entry barrier and capital intensity) directly affects firm conduct (R&D intensity) and performance (ROA).
EN
In this study the Maximum Likelihood Estimator is taken to identify the characteristics of insulation failure about the class-H motors by considering the accelerated life testing data under censored situation from Nelson. Based on the Weibull survival modeling the failure is expressed as the series connection of three modes, namely the turn, phase, and ground, respectively, the so-called competing failure. The main concern in present investigation is about the variation of shape parameters, β with the temperature. The Gompertz-type relation of βi(T) is suggested with the reference temperature, Tri for the i-th failure mode. It is found that the Tri ’s not only distinguish the characteristics of cumulative damage process about the insulation, but also involve the estimation of mean-time-to-failure (MTTF). Physically Tri denotes the turning point of varied βi as the i-th failure mode becomes moderate in a sense of less capability about the accumulation of insulation damage at higher temperature where corresponds the thermal degradation process. The numerical results indicate that the insulation technique used is acceptable as the operation temperature kept in the use condition 363K. According to the predicted lifetime as the temperature rises up to 440K, which still within the allowed range in application, the turn structure needs to be rearranged primarily, then the phase next. The ground mode has only influence on the failure at much higher temperature.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.