Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A biogas plant can be a source of waste-heat flows with different thermal parameters. Application of such flows in local, low-temperature district-heating networks is a very attractive option for highly efficient, energetically and economically, co-generation systems applying biogas as the primary energy source.
EN
In February 2004 the International Maritime Organization (IMO) adopted the International Convention for the Control and Management of Ships’ Ballast Water and Sediments (BWM Convention). There are regulations of ballast water discharges and methods of risk reducing of introducing non-native species. To complement the BWM Convention, the IMO has adopted the guidelines prepared as resolutions and circulars by Maritime Environment Protection Committee (MEPC). In addition to the IMO, other national or regional bodies have introduced own regulations for example the United State Coast Guard rules. At first the D-1 standard of ballast water was obligatory. The BWM Convention has entered into force in 8th of September, 2017 and it needs the D-2 standard of ballast water cleanliness. The article presents the ballast water managements systems, the cleanliness requirements, solutions of ballast water treatment and expectations for improvement the quality of ballast water pumped outboard and the decreased risk for the environment. It was discussed the D-1 standard of ballast water required from February 2004 and its imperfections. The routine ought to be the cleaning of the ballast tank to remove sediments, possible in mid-ocean or under controlled arrangements in port or dry dock. The marine market is so considerable and important for manufacturers that they prepared full ready systems and still tried them to develop as to the effectiveness of cleaning process, the fulfillment of cleanliness standard, the minimal mass and dimensions of the pack, the minimal required electric energy, automatic operation with very little crew attention, series of types (different capacities) – the most often proposition is only with one capacity, for bigger capacity there is a possibility by using more than one pack, the long term life, the total cost of investment and operation etc. As an example it was presented the HG250GS system of Hyde Marine. As an very important solution is an automatic backwashing filter with continuous filtration and flow to ballast tanks is the first stage. The second stage uses high intensity of ultraviolet (UV) treatment for disinfection. UV dosage results from a combination of lamp power flow path and exposure time. The cleanliness of UV lamp glasses is very important, so the washing systems for lamp glasses ought to be installed. The effectiveness of ballast water treatment depends on many factors – they were indicated. The existing and unsolved problem is the cleanliness state inside the ballast tanks and inside the ballast water pipelines. As a final remark – the expectations concerning to ballast water treatment systems are not properly verified.
PL
W lutym 2004 roku Międzynarodowa Organizacja Morska (IMO) wprowadziła Międzynarodową konwencję o kontroli i zarządzaniu statkowymi wodami balastowymi oraz osadami z wód balastowych (Konwencja BWM). Przedstawiono w niej regulacje możliwości usuwania wody balastowej za burtę oraz metody zmniejszenia ryzyka wprowadzania do środowiska obcych gatunków. Dopełnieniem Konwencji są przewodniki, rezolucje i okólniki przygotowane przez Komitet Ochrony Środowiska Morskiego (MEPC). Dodatkowo, oprócz IMO, narodowe lub regionalne administracje morskie mogą wprowadzać własne regulacje np. wymagania Amerykańskiej Straży Granicznej (USCG). Początkowo standard D-1 wód balastowych był obligatoryjny. Po wejściu wymogów Konwencji BWM w dniu 8 września 2017 roku, wymaga się spełnienia standardu D-2 czystości wód balastowych. W artykule przedstawiono systemy zarządzania wodami balastowymi, wymagania czystości, rozwiązania obróbki wód balastowych oraz oczekiwania związane ze zwiększeniem jakości wód balastowych i zmniejszeniem ryzyka dla środowiska. Poddano dyskusji standard D-1 obowiązujący od lutego 2004 roku oraz jego niedoskonałości. Czynnością rutynową winno być czyszczenie zbiorników balastowych z osadów, możliwe do przeprowadzenia na otwartym oceanie lub pod kontrolą urządzeń portowych lub suchego doku. Rynek urządzeń okrętowych jest tak istotny i ważny dla producentów, że są oni w stanie przygotować w pełni gotowe systemy, będą je rozwijać, aby spełnić wymagania efektywności procesu czyszczenia, wymagania standardów czystości, jak najmniejszej masy i gabarytów urządzenia, jak najmniejszego zapotrzebowania na energię elektryczną, automatyzacji procesu z jak najmniejszą pracochłonnością dla załogi, budowy typoszeregu (o różnych wydajnościach – obecnie propozycje dotyczą jednego typu urządzenia z jedną wydajnością, można zastosować kilka urządzeń w celu zwiększenia wydajności), wieloletniego okresu użytkowania, całkowitych kosztów inwestycji i eksploatacji. Jako przykład przedstawiono system HG250GS firmy Hyde Marine. Ważnym rozwiązaniem jest zastosowanie w pierwszym stopniu automatycznego filtra umożliwiającego pracę urządzenia podczas jego czyszczenia. Jako drugi stopień stosuje się intensywne napromieniowanie ultrafioletem (lampami UV) w celu dezynfekcji wody balastowej. Dawka promieniowania lamp UV jest ustalana jako kombinacja mocy lampy UV i czasu naświetlania. Czystość szkieł lampy UV ma decydujące znaczenie dla skuteczności procesu, dlatego zainstalowano system ich czyszczenia. Wskazano na wiele parametrów, od których zależy efektywność obróbki wody balastowej. Istniejącym i nierozwiązanym problemem jest stan czystości zbiorników balastowych i rurociągów obsługujących tą instalację w czasie eksploatacji. Końcową uwagą jest, że oczekiwania dotyczące skutecznej obróbki wód balastowych nie zostały w pełni zweryfikowane.
EN
Modern programs of studies, in particular for technical majors, include classes which take place in computer rooms. Such subjects are numerous in particular at technical schools / universities and the major which is leading one is the IT. In the paper authors presented factors which have a significant impact on consumption of the electric energy in a computer room. The analysis in question shows that change of habits of students using computer rooms is important because of relatively large savings in consumption of the electric energy and lower costs of maintenance of computer rooms. Survey was carried out in order to learn habits of users of computer rooms. Then software was demonstrated enabling remote and effective management of computer platforms. The system was based on equipment technology "Intel Active Management Technology" which also is characterized in the paper. The system functionality was developed on the basis of experience and administrators’ requirements of the computer network and IT class teachers. The most important functionalities of the system comprise collection of information on power supply of the platforms, as well as changing this state, collection of information on sub assemblies of a computer, scanning of machines IPs and archiving them. Elaborated software was equipped with two types of interfaces. In relation to known commercial solutions, developed interfaces improved efficiency of the system and enhanced ergonomics of platforms management. As a conclusion the analysis of the electric energy consumption in a computer room has been presented the consumption without application of the system and after it has been implemented. Also the environment protection is part of this paper since it is a part of made analysis of the electric energy consumption in teaching centers.
PL
Nowoczesne programy studiów prowadzone w szczególności na kierunkach technicznych, obejmują przedmioty, które w części praktycznej realizowane są w pracowniach komputerowych. Takich przedmiotów jest szczególnie dużo na uczelniach technicznych, a kierunkiem, który wiedzie prym w tym zakresie jest informatyka. W pracy przedstawiono czynniki, które mają istotny wpływ na zużycie energii eklektycznej w pracowni komputerowej. Analiza ta pokazuje, że zmiana nawyków zachowania studentów korzystających z pracowni komputerowych jest istotna ze względu na relatywnie duże oszczędności w zużyciu energii elektrycznej i w obniżeniu kosztów utrzymania pracowni. Przeprowadzono badanie ankietowe, w którym rozpoznano nawyki użytkowników pracowni komputerowych. Następnie przedstawiono oprogramowanie, które umożliwia zdalne i efektywne zarządzanie stanem platform komputerowych. System ten oparty został na technologii sprzętowej "Intel Active Management Technology", która również została scharakteryzowana w pracy. Funkcjonalność systemu opracowano na podstawienie doświadczenia i wymagań zespołu administratorów sieci komputerowej i prowadzących zajęcia informatyczne. Do najważniejszych funkcjonalności systemu należy pobieranie informacji o stanie zasilania platform i zmienianie go, pobieranie informacji o podzespołach komputera, skanowanie adresów IP maszyn i archiwizowanie ich. Powstałe oprogramowanie wyposażone zostało w dwa typy interfejsów. W stosunku do znanych rozwiązań komercyjnych stworzone interfejsy wpłynęły na poprawienie wydajności systemu oraz zwiększyły jego ergonomię w zarządzaniu platformami. Jako podsumowanie przedstawiono analizę zużycia energii elektrycznej w pracowni komputerowej bez zastosowania systemu i po jego implementacji. W artykule pokazano występującą problematykę ochrony środowiska, którą obejmuje przeprowadzona analiza zużycia energii elektrycznej w ośrodkach dydaktycznych.
PL
W opracowaniu przedmiotem badań jest wytwarzanie energii cieplnej. W wyniku tego zjawiska następuje emisja zanieczyszczeń do atmosfery. Wielkość emisji uzależniona jest od rodzaju i ilości spalanego paliwa. W pracy przedstawiono parametry techniczno-technologiczne urządzeń energetyki cieplnej wykorzystywane w procesie badawczym. W obiekcie eksploatowane są dwa kotły Paromat-Simplex z palnikami Weishaupt L5T D oraz jeden kocioł Paromat ER ND z palnikiem Weishaupt L1Z-B. W pracy dokonano obliczeń wielkości i parametrów emisji. Przeprowadzono badania i obliczenia stężeń emitowanych zanieczyszczeń dla kotłowni olejowej wodno-parowej, eksploatowanej przez obiekt zlokalizowany w Gdańsku Stogach. Badania dotyczą również wykorzystania źródeł energii odnawialnej. W wyniku przeprowadzonych badań porównawczych z zastosowaniem kotła Pilewang Gizex – PM stwierdzono, że oddziaływanie spalania słomy na stan czystości powietrza atmosferycznego jest mniej negatywne niż spalania węgla. Bilans emisji dwutlenku węgla podczas spalania biomasy jest zerowy, gdyż wytworzona jego ilość jest równoważna ilości CO2 pobranej przez roślinę podczas jej wzrostu. Analizą objęto również współpracę kotłowni z zespołem pomp ciepła. System hybrydowy uwzględnia różną moc zainstalowaną w pompach ciepła w granicach Qpc = 13,5-67,5 kW. Moc szczytowa kotłów jest równa Qhybr. = 262,5 kW. Zastosowanie pomp ciepła zmniejszy emisję dwutlenku węgla, odpowiednio dla QPC = 67,5 kW o ∆BCO2 = 33 Mg/a oraz dla QPC = 13,5 kW o ∆BCO2 = 6,6 Mg/a. Z uwagi na to, że badany obiekt zlokalizowany jest na terenie Nadmorskiego Parku Krajobrazowego, wskazane jest możliwie największe ograniczenie emisji zanieczyszczeń z kotłowni (dwutlenku węgla, tlenków siarki, tlenków azotu). Wykorzystanie odnawialnych źródeł energii przez lokalną energetykę cieplną jest korzystne dla ochrony środowiska.
EN
The research is related to thermal energy production and related air pollutions. As a result of this process, emission of pollution to the atmosphere occurs. The effect of pollution depends on the sort and amount of combusted fuel. Technical and technological parameters of thermal energy installations, which have been used in the research process, have been presented. In the building there are two Paromat-Simplex boilers with Weishaupt L5T D burners. In addition to this, a boiler Paromat ER ND with Weishaupt L1Z-B burner is installed. The boilers characteristics are discussed. The influence of thermal energy sources on the environment has been taken into account. Calculations of the volume and parameters of emission have been conducted. The research also concerns the use of renewable energy. As a result of the comparative research with the application of Pilewang Gizex – PM boiler it was found that the influence of straw combustion on the quality of air is less negative than coal combustion. Carbon dioxide emission of biomass combustion is neglected because its amount equals the amount of CO2 absorbed by a plant during its growth. The analysis includes also the hybrid system of a boiler with a set of heat pumps in the power range Qpc = 13,5-67,5 kW. Maximum power of boilers is Qhybr. = 262,5 kW. The application of heat pumps reduces carbon dioxide emission: for QPC = 67,5 kW reduction is ∆BCO2 = 33 Mg/a and for QPC = 13,5 kW it correspond to ∆BCO2 = 6,6 Mg/a. Due to the fact that the object being the subject of the research is located in the Coastal Landscape Park (pol. Nadmorski Park Krajobrazowy) it is advisable to significantly reduce emission of pollution from boilers (carbon dioxide, sulfur oxides, nitrogen oxides). The application of renewable sources of energy by local thermal power engineering is favorable for the protection of the environment.
EN
The effective utilization of waste heat it is great challenge for highly efficient co-generation based on biogas. The possibility for highly efficient co-generation using biogas is analyzed. The system generating 500 kWe and 700 kWh, where main heat receiver would be village or small city region with central heating system and heat storage system is considered. Both home heating and hot water supply is discussed.
EN
This article concerns using renewable energy resources. It contains an analysis of pollution emissions created by combustion of conventional and unconventional energy resources. It provides examples of cogeneration systems. In particular, it focuses on a system correlated with a gas turbine and a system correlated with a piston combustion engine. Attention is paid to the issue of applying innovative solutions in heating technology.
EN
The article presents the energy performance of a heat pump. The coefficient of performance was taken into account, which is the ratio of the heating energy obtained to the supplied electrical energy necessary for the compressor operation. The focus was on the issue of operating costs of using heat pumps. These costs are mainly influenced by two factors. Firstly, energy performance and the purchase price of electricity. The second factor is investment costs. Heat gains from solar energy were characterized. The value of the solar radiation transmission coefficient for the double glazing was assumed (TR = 0.7). Solar gains were shown in January for windows on the eastern and western facades. The analysis covered the seasonal heat demand for heating. The studies and calculations took into account the occurring heat losses and heat gains from the sun and internal sources with their utilization rate. Particular attention was paid to the fact that the peak power of heating appliances can be calculated by knowing the value of the annual energy demand for heating a building that takes into account the most severe external conditions prevailing in a given climate zone, i.e. the minimum outside temperature.
PL
W opracowaniu pt. Termodynamiczne czynniki robocze stosowane w pompach ciepła opisano geotermię niskotemperaturową. Przedstawiono podstawowy podział pomp ciepła. Scharakteryzowano czynniki robocze stosowane w pompach ciepła. Omówiono przeprowadzone badania dotyczące stosowanych w technice cieplnej czynników z grupy CFC i HCFC. W szczególności analizą objęto harmonogram wycofania z użytku czynników chlorowcowopochodnych zakwalifikowanych do ww. grupy. Uwzględniono w analizie wskaźniki ekologiczne niektórych czynników chłodniczych. Pokazano, że wskaźnik ekologiczny ODP charakteryzuje wpływ danego czynnika na intensywność rozkładu ozonu. Natomiast GWP opisuje wpływ czynnika na potęgowanie efektu cieplarnianego. Z kolei TEWI jest wskaźnikiem umożliwiającym ocenę globalnego ocieplenia atmosfery, spowodowanego eksploatacją pompy ciepła lub urządzenia chłodniczego. Zwrócono uwagę na sposób obliczania wartości wskaźnika TEWI. Wyspecyfikowano podstawowe właściwości najczęściej stosowanych zamienników R22. Wskazano na zmianę parametrów eksploatacyjnych pomp ciepła spowodowaną wprowadzeniem nowych czynników roboczych. W niniejszym opracowaniu podano również niezbędne kryteria uwzględniane w procesie badań i oceny przydatności czynników roboczych do pracy w obiegu pomp ciepła. Odniesiono się do efektywności energetycznej w przypadku eksploatacji pomp ciepła z wykorzystaniem źródeł niskotemperaturowych powodujące redukcję emisji CO2. W badaniu ustalono poziom korzystnego wpływu tej emisji w porównaniu z potencjałem konwencjonalnych źródeł energii. Szczególną uwagę zwrócono na technologiczne rozwiązania w zakresie minimalizacji zawartości czynnika roboczego w instalacji, związanego z ograniczeniem jego emisji do atmosfery. Przewody obiegu czynnika roboczego, łącząc poszczególne elementy i urządzenia, tworzą zamkniętą instalację pompy ciepła. W montażu miedzianych instalacji pomp ciepła stosowane są specjalne rury miedziane przeznaczone do chłodnictwa i klimatyzacji.
EN
In the article entitled “Thermodynamic heat exchangers used in heat pumps” lowtemperature geothermal energy was described. Basic classification of heat pumps was presented. Heat exchangers and the research concerning heat exchangers representing groups CFC and HCFC, which are used in the heat technology, were described. In particular, the schedule of withdrawal from use chlorine-derived exchangers, which belong to the latter groups, was analyzed. Ecologic indicators of some refrigerants were taken into account. It was presented that ecologic indicator ODP illustrates the influence of a certain refrigerant on an intensity of ozone decomposition. GPW indicates the influence of a certain refrigerant on the greenhouse effect. TEWI is an indicator which allows to assess global warming of the atmosphere, caused by heat pumps or refrigerating equipment. It was especially highlighted how the TEWI indicator is calculated. Basic features of most commonly used R22 replacements were specified. It was shown how exploitation parameters of heat pumps change if new heat exchangers are applied. In the article, the most significant criteria of heat exchanger evaluation in terms of their applicability in the heat pump loop were presented. The energetic efficacy of the heat pump exploitation using low-temperature geothermal energy and its CO2 emission reduction was mentioned. The results of the research establish the level of positive influence of this kind of emission in comparison with conventional sources of energy. Particular attention was paid to the technological solutions in the field of minimization the amount of heat exchanger in the installation, related to the reduction of its emission to the atmosphere. Pipes for heat exchanger circuit connect all modules and devices, creating closed installation of heat pump. In the installation process of copper heat pump systems, special copper pipes, dedicated to refrigeration and air conditioning, are used.
PL
W niniejszym opracowaniu przedstawiono możliwość zastosowania układu kogeneracyjnego przy współpracy pomp ciepła z kotłownią olejową i siecią ciepłowniczą. W procesie badawczym objęto odzysk ciepła odpadowego z silnikiem Stirlinga. Odzyskane ciepło odpadowe ze spalin kotłowych zużyte jest do napędu silnika Stirlinga, który napędza prądnicę. Wykonano obliczenia bilansu energetycznego. Obliczone wartości średniej temperatury spalin Tsr i temperatury otoczenia Tot pozwalają wyznaczyć aktualną sprawność silnika Stirlinga. Wykonany bilans energetyczny oszacowuje ilość możliwej do wytworzenia energii elektrycznej. Ilość ta jest mocno zróżnicowana dla różnych wartości zewnętrznej temperatury otoczenia. Opisano bilans energetyczny dla przypadku, gdy kotłownia sama w całości pokrywa zapotrzebowanie na ciepło. Scharakteryzowano współpracę kotłowni z pompami ciepła. Rozpatrzono pięć wariantów współpracy, wyznaczonych mocą cieplną zainstalowanych pomp ciepła. W każdym z tych wariantów inne są wartości wytworzonej mocy oraz energii elektrycznej z odzysku ciepła. Moc i energia elektryczna może być wykorzystana do napędu pomp ciepła, ewentualnie do pokrycia innych potrzeb. Przeprowadzono analizę wyników obliczeń dotyczących mocy i energii elektrycznej wytworzonych z odzysku ciepła odpadowego ze spalin kotłowych oraz mocy i energii elektrycznej potrzebnych do napędu pomp ciepła. Z analizy wyników obliczeń zawartych w tabeli 1 dotyczącej wytworzonej mocy i energii elektrycznej w sezonie grzewczym, wynika, że ogółem energia elektryczna z odzysku ciepła odpadowego ze spalin wynosi Eel = 18 238,88 kWh/a. Natomiast największa, uzyskana z odzysku ciepła odpadowego ze spalin, moc mechaniczna silnika Stirlinga jest równa Nmstir = 8,04 kW. Wartość ta pozwala określić moc znamionową silnika do zastosowania w badanym obiekcie.
EN
The article presents applicability of CHP system combining heat pumps, oil boilers and heating network. The research includes waste heat recovery by means of the Stirling engine. Recovered waste heat is used to propel Stirling engine, which propels a generator of electricity. Energy balance was calculated. Calculating average temperature of fumes Tsr and ambient temperature Tot allowed to find actual efficiency of the Stirling engine. Calculated energy balance estimates the amount of electricity which is possible to generate. This amount varies significantly depending on the ambient temperature. In this case the energy balance is calculated for the situation in which a boiler is able on its own to fully cover the demand of heat. The cooperation between boilers and heat pumps was characterized. Five different variants of cooperation were considered, in each variant a heat pump has a different power. In each variant different parameters of electric power and energy from recovered heat were obtained. The energy produced in this way can be used either to propel the heat pump or to cover other needs. The author conducted the analysis of calculation results concerning the electric power and energy produced from the recovered waste heat from boiler fumes as well as electric power and energy necessary to propel heat pumps. The results of the analysis (Table 1) concerning the electric power and energy produced during a heating season show that the general electric energy obtained from the recovered waste heat from boiler fumes is Eel = 18 238,88 kWh/a. Moreover, the highest mechanic power of the Stirling engine, obtained from the waste heat from the fumes is Nmstir = 8,04 kW.
10
Content available remote Wybrane zagadnienia efektywności pomp ciepła w energetyce cieplnej
PL
W opracowaniu wybrane zagadnienia efektywności pomp ciepła w energetyce cieplnej zaprezentowano podział i wykorzystanie pomp ciepła. Przedstawiono ekonomiczną efektywność układów ogrzewania z pompą ciepła. Omówiono zastosowanie pomp ciepła do hybrydowego układu ogrzewania. W pracy uwzględniono występujące możliwości technologiczno-techniczne pompy ciepła. Scharakteryzowano dane techniczne wybranej pompy ciepła.
EN
The work concerns the selected aspects of heat pumps effectiveness in the thermal industry; it presents the classification and use of heat pumps. It shows the efficiency of heating systems with heat pumps and describes the use of heat pumps in hybrid heating systems. The work considers the existing technological and technical opportunities of the PC Stiebel Eltron heat pump. The work presents the technical parameters of the selected heat pump.
11
Content available remote Problematyka współpracy pomp ciepła z siecią ciepłowniczą
PL
W pracy przedstawiono problematykę współpracy pomp ciepła z siecią ciepłowniczą. Uwzględniono przeprowadzone badania w tym zakresie dla obiektu zlokalizowanego w pierwszej strefie klimatycznej. Scharakteryzowano przyjęte warianty obliczeniowe wskaźników eksploatacyjnych z dokonanych badań. Przeprowadzono analizę wariantów obliczeniowych wskaźników eksploatacyjnych. Analizowane zagadnienie pokazano w ujęciu tabelarycznym i graficznym. Wskazano na możliwość zastosowania optymalnego wariantu obliczeniowego do współpracy pomp ciepła z siecią ciepłowniczą.
EN
In the following research work it has been presented the issue of heating pumps cooperation with the heating network. The research which has been carried out is consideration within this scope for the building located in the first climatic zone. The established computational versions of exploitation indicators have been characterized. The computational versions analysis of exploitation indicators has been conducted. The issue being analysed is presented in tabular and graphic layout. It has also been indicated the possibility of employing the optimal computational version for the cooperation of heating pumps with the heating network.
12
Content available remote Zastosowanie pomp ciepła w energetyce cieplnej
PL
Przedstawiono zastosowanie pomp ciepła w energetyce cieplnej. Uwzględniono podział i wykorzystanie pomp ciepła. Scharakteryzowano źródła ciepła niskotemperaturowego. Zaprezentowano ekonomiczną efektywność układów ogrzewania z pompą ciepła.
EN
It has been presented the use of heat pumps in thermal energetics. The partition and utilization of heat pumps has been included. The sources of low - temperature heat have been characterized. The economic effectiveness of heating systems with the heat pump has been introduced.
13
Content available remote Wybrane zagadnienia wykorzystania energii słonecznej w energetyce cieplnej
PL
W artykule przedstawiono wybrane zagadnienia wykorzystania energii słonecznej. Omówiono przykłady stosowania instalacji solarnych. Scharakteryzowano zastosowanie kolektorów słonecznych w budownictwie. Dokonano analizy uzyskiwanych efektów ekoIogicznych i ekonomicznych.
EN
The article presents selected aspects of using solar energy. Examples of using solar installations have been discussed. Using solar collectors in architecture construction have been characterized. Achieved ecological and economic effects have been analysis.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.