Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
For safety reason it is required to check periodically concentration of non- flammable components in dust deposited in coal mines entries . The traditional procedurę requires the dust samples to be collected in locations determined by safety regulations and transport them to the surface where the concentration of non- flammable components can be evaluated in the laboratory. It would greatly simplified the required procedurę if the dust samples could be tested directly on site . Attempts to construct the suitable equipment, based on measurements of relative intensity of light reflected from dust sample, although almost completed, finally has been abandoned because the manufacturer of reflectometric sensors ceased its production. The following paper presents results of research project which goals was to develop probe, based on commonly available components, which could substitute, the initial sensor choice and further to make possible to complete finally the measuring device. It seems that the initial goal of the project has been successfully achieved.
PL
Ze względów bezpieczeństwa wymagane jest okresowe sprawdzanie stężenia niepalnych składników w pyle znajdującym się w wyrobiskach kopalń. Tradycyjna procedura badawcza wymaga pobrania próbek pyłu w miejscach określonych przez przepisy bezpieczeństwa i przetransportowania ich na powierzchnię, gdzie stężenie niepalnych składników może być oceniane w laboratorium. Znacznym uproszczeniem wymaganej procedury byłoby badanie próbek pyłu bezpośrednio na miejscu w wyrobisku. Prowadzone były próby skonstruowania odpowiedniego sprzętu badającego względne natężenia światła odbitego od próbki pyłu.Jednak pomimo prawie zakończonych badań pomysł ten został porzucony z uwagi na fakt, iż producent czujników reflektometrycznych zaprzestał ich produkcji. W pracy przedstawiono wyniki badań, których celem było opracowanie sondy, w oparciu o powszechnie dostępne elementy. Mogą one zastąpić pierwotnie wybrany przetwornik reflektometryczny i umożliwić zakończenie budowy urządzenia pomiarowego. Wydaje się, że początkowy cel projektu został skutecznie osiągnięty.
PL
Indukcyjność wewnętrzna źródła zasilania występuje w postaci konkretnych skupionych elementów, na przykład uzwojenia transformatorów separujących, cewki filtrów przeciwzakłóceniowych itp. W niektórych przypadkach oddziaływanie negatywne tych elementów indukcyjnych na iskrobezpieczeństwo obwodu wyjściowego można kompensować lub nawet wykorzystać do zwiększenia iskrobezpieczeństwa obwodu zewnętrznego źródła zasilania, szczególnie przy zastosowaniu nieliniowych układów ochronnych, zapewniających iskrobezpieczeństwo, ze względu na ich większy współczynnik przenoszenia energii elektrycznej w porównaniu z liniowymi układami ochronnymi. W artykule opisano modele matematyczne do estymacji wpływu indukcyjności wewnętrznej źródła zasilania na iskrobezpieczeństwo obwodu wyjściowego przy stosowaniu układów ochronnych z nieliniową charakterystyką prądowo-napięciową typu fold-back, dla różnych impedancji obciążenia. Uzyskane analityczne wyrażenia do estymacji energii elektrycznej wydzielonej w kanale wyładowania elektrycznego, wskutek oddziaływania źródła zasilania, jego indukcyjności wewnętrznej oraz parametrów obciążenia, pozwalają z wykorzystaniem wspomagania komputerowego a priori określić stopień iskrobezpieczeństwa obwodu elektrycznego, jak również dokonać analizy wrażliwości iskrobezpieczeństwa tego obwodu w zależności od zmian parametrów elektrycznych poszczególnych elementów. Stwierdzono, że wpływ indukcyjności wewnętrznej źródła zasilania zależy od impedancji wejściowej obwodu chronionego, jak również od charakteru komutacji awaryjnej, zwarcia lub rozwarcia w tym obwodzie. Przy pojemnościowym charakterze obciążenia w chwili powstania zwarcia na wyjściu źródła zasila­nia obecność indukcyjności wewnętrznej źródła zasilania łagodzi jego oddziaływanie, zmniejszając szyb­kość wzrostu prądu i wartości energii elektrycznej, wyzwalanej w punkcie zwarcia, nowelizując przy tym skutki opóźnienia zadziałania układu ochronnego. Przy obciążeniu typu RL w chwili powstania rozwarcia na wyjściu źródła zasilania około 20% energii magnetycznej, zgromadzonej w indukcyjności wewnętrznej źródła zasilania, jest wydzielane w kanale wyładowania elektrycznego, natomiast przy zadziałaniu układu ochronnego, dokonującego zwarcia zacisków wyjściowych źródła zasilania w chwili powstania komutacji awaryjnej, wartość ta jest do pominięcia. W warunkach rzeczywistych występuje opóźnienie zadziałania układu ochronnego od chwili powstania komutacji awaryjnej, które powinno być uwzględnione przy symulacji zmiany w czasie rezy­stancji układu ochronnego lub przy obliczeniu odpowiednich całek w sposób numeryczny.
EN
The intemal inductance of the supply source appears in the form of defined self-contained elements, for example winding of separating transformers, coil of anti-interference filters and the like. In somecases the negative influence of these inductive elements on the intrinsic safety of the output circuit can be compensated or even used to increase the intrinsic safety of the external circuit of supply source, particularly by applying non-linear protective systems that guarantee the intrinsic safety, on account of their higher coefficient of electric energy transfer, as compared to the linear protective systems. The paper presents mathematical models for estimation of the effect of internal inductance of the supply source on intrinsic safety of the output circuit, when applying protective systems with non-linear fold-back type current-voltage characteristics, for various impedances of the load. The analytic expres-sions obtained for estimation of electric energy generated in a channel of electrical discharge, as a result of the effect of the supply source, its internal inductance and load parameters, enable, by using computer assistance, to determine a priori the level of intrinsic safety of the electric circuit, as well as to carry out an analysis of this circuit intrinsic safety sensitivity, depending on the changes of electrical parameters of individual parameters. It has been found that the effect of internal inductance of the supply source depends on the input impedance of the protected circuit, as well as on the nature of emergency commutation, short-circuit or break in this circuit. With the capacitive character of load at the moment of short-circuit occurrence at the output of the supply source, the presence of the internal inductance of the supply source mitigates its effect, by reducing the rate of rise and the value of electric energy liberated in the point of short-circuit, at the same time modifying the effects of of the delay of the protective system activation. With the load of RL type at the moment of circuit breaking occurrence, at the output of the supply source, about 20% of magnetic energy accumulated in the internal inductance of the supply source is being liberated into the electrical discharge channel, whereas with the of protective system operating, causing short-circuiting of the output clamps of the supply source at the moment of emergency commutation, this value can be omitted. In the real conditions there is a delay in activation of the protective system sińce the moment of emergency commutation occurrence that should be taken into consideration when simulating t the time change of the protcctive system resistance, or when computing apprropriate integrals.
PL
W artykule omówiono podstawowe cechy funkcjonalne i budowę przekaźnika lokalnego rezerwowania wyłączników oznaczonego symbolem TLH-5, przeznaczonego dla rozdzielni 110 kV w układzie H, na tle wymagań użytkowników, a także różnych rozwiązań układów automatyki LRW stosowanych w rozdzielniach wysokich i najwyższych napięć.
EN
The article discusses the principle of operation and construction of the relay type TLH-5 for the breaker failure protection automatics (LRW), developed and implemented for production by ZPrAE Ltd.
PL
W artykule omówiono zagadnienia zwiazane z automatyką lokalnego rezerwowania wyłączników rozdzielni 110kV w układzie H oraz przekazano podstawowe informacje na temat przekaxnika typu TLH-5, opracowanego i oferowanego przez ZPrAE, a przeznaczonego dla tego typu rozdzielni.
EN
The article discusses issues concerning the breaker failure protection automatics intended for 110kV substations in H arrangement and presents basic information about the TLH-5 relay designed and offered by ZPrAE meant for such substations.
PL
Autor w referacie podejmuje problem selektywności pomiarów gazowych składników atmosfery kopalnianej. Ograniczona selektywność czujników stosowanych w aparaturze gazometrycznej jest przyczyną błędnych wyników pomiarów, co jest równoznaczne z błędną oceną poziomu zagrożeń gazowych. Problem staje się szczególnie istotny w warunkach pożaru z powodu złożonego składu gazów pożarowych. Poprawę selektywności pomiarów można osiągnąć poprzez przetwarzanie sygnałów wieloczujnikowych głowic bazujących na konwencjonalnych sensorach gazów. Przedstawione w referacie koncepcje identyfikacji składu ilościowego gazów pożarowych, wykorzystują metody matematyczne i technikę sztucznych sieci neuronowych.
EN
This paper discusses a problem of measurement of mine atmosphere components. The limited selectivity of detectors used in gas measurement equipment yields faulty measurement results which is equivalent to false assessment of gas hazard level. This problem becomes particularly important in fire conditions, because of a complex composition of fire gases. An improvement of measurement selectivity may be achieved by conversion of signals from multidetector heads, based on conventional gas sensors. This paper includes the general concepts of identification of fire gas quantitative composition that use mathematical methods and artificial neural networks technique.
PL
ZPrAE Sp. z o.o. jest firmą inżyniersko-produkcyjną, od lat specjalizującą się w produkcji zabezpieczeń szyn zbiorczych (ZSZ) z układami rezerwowania wyłączników (URW), a także w badaniach eksploatacyjnych i poawaryjnych oraz w remontach tych urządzeń. Od 4 lat ZPrAE produkuje i dostarcza krajowej energetyce zabezpieczenia szyn zbiorczych zintegrowane z układem rezerwy wyłącznikowej typu TSL-6. W związku z potrzebami eksploatacji, w ZPrAE podjęto się opracowania nowego cyfrowego układu rezerwowania wyłączników w tzw. „wersji rozproszonej", składającego się z jednostki centralnej i terminali polowych przystosowanych do instalowania w szafach zabezpieczeń dla poszczególnych pól rozdzielni, oznaczonego jako TL-6r. Logika działania nowego układu odpowiada wymaganiom obwodów wtórnych dużych stacji najwyższych napięć. Wymagania te zostały sprecyzowane przez specjalistów z PSE SA w trakcie wielu konsultacji.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.