Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Earliest deadline first (EDF) and fixed priority (FP) are the most commonly used and studied scheduling algorithms for real-time systems. This paper focuses on combining the EDF and FP strategies in one system. We provide a new sufficient schedulability analysis for real-time hybrid task systems which are scheduled by EDF and FP. The proposed analysis has a polynomial time complexity and no restrictions on task parameters, where the relative deadline of each task could be less than, equal to, or greater than its period. By extensive experiments, we show that our proposed analysis significantly improves the acceptance ratio compared with the existing results of the sufficient schedulability test for hybrid scheduling systems.
2
Content available remote Highly sensitive tunable diode laser absorption spectroscopy of CO2 around 1.53 m
EN
The absolute absorption spectrum intensities of carbon dioxide sample have been recorded with a tunable diode laser spectrometer in the spectral range 6506-6520 cm-1, which is suitable for the in situ sensing of carbon dioxide in the lower stratosphere, and were studied using a commercial telecommunication-type diode laser. The intensity of the weakest line we detected in this experiment is 9.116×10-27 cm-1/(moleculeźcm-2) at a pressure of 0.35 torr, and the corresponding absorption is 1.96×10-6 with SNR of 2.67.
EN
Zinc(II) imprinted amino-functionalized silica gel sorbent was synthesized applying surface-imprinting technique in order to preconcentrate and separate Zn2+ prior to its determination by inductively coupled plasma optical emission speclrometry (1CP-OES). Compared to traditional solid sorbents and non-imprinted sorbent, zinc(U)-irnprinted sorbent has higher selectivity and adsorption capacity towards Zn2+. Maximum static adsorption capa cities of ion-imprinted and non-imprinted sorbent towards Zn2+ were 12.98 mg g-1 and 4.36 mg g -1, respectively. The largest separation factor for zinc(II) imprinted sorbent towards Zn+2 in the presence of Hg+2 was higher than 188. Relative selectivity coefficient (&alfa;r) values for Zn+2 Hg+2 pair were 15.5 and 13.8-both greater than 1. Distribution coefficient (D) valuesofzinc(II) imprinted polymers to wards Zn2+ were greatly larger than those for Hg+2 . Detection limit (3 σ) of the method was 0.29 μg L-1 and relative standard deviation equalled 2.6% for eight replicate determination of 10 μg of Zn+2 in 200 mL-in-volume water sample. The proposed method was applied to the determination of trace zinc in biological and water samples with satisfactory results.
PL
Zsynletyzowano sorbent krzemionkowy do którego wprowadzono grupy aminowe z dopasowanym molekularnie Zn(II) stosując technikę dopasowania powierzchniowego. Sorbent . został zastosowany do wstępnego zatężenia i oddzielania Zn2+ przed jego oznaczaniem za pomocą spektometrii emisyjnej z plazmą sprzężoną indukcyjnie (ICP-OES). W porównaniu do tradycyjnych sorbentów oraz tego samego sorbentu „bez dopasowania molekularnego'', sorbent „z dopasowaniem molekularnym względem Zn(tl)" wykazuje lepszą selektywność i wyższą zdolność sorpcyjną względem 72+. Maksymalne zdolności sorpcyjne względem cynku sorbentu „z dopasowaniem" i „bez dopasowania molekularnego" wynosiły odpowiednio: 12.98 mg g-1 oraz 4.36 mg g-1. Największy współczynnik rozdzielenia jonów Zn+2 i Hg+2 w przypadku jonitu „z dopasowaniem molekularnym względem Zn(II)'' przewyższał 188. Względny współczynnik selektywności określający na ile współczynnik rozdzielenia pary Zn+2/Hg+2 w przypadku sorbentu ,.z dopasowaniem względem Zn(II)" jest lepszy niż w przypadku sorbentu ,,bez dopasowania został wyznaczony jako 15.5 lub 13.8 a więc był znacznie większy niż 1. Współczynniki podziału (D) dla jonitu z dopasowaniem Zn(II)były znacznie wyższe dla Zn+2 niż dla Hg+2. Granica wykrywalności (3σ) metody wyniosła 0.29 μ.g L-1 a względne odchylenie standardowe obliczone z ośmiu kolejnych oznaczeń 10 μg Zn+2 w 200 mL próbce wody wynosiło 2.6%. Zaproponowaną metodę zastosowano z powodzeniem do oznaczania śladów cynku w materiałach biologicznych i próbkach wody.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.