Currently, overhead lines dominate in the Polish medium and low voltage distribution networks. Maintaining their high reliability constitutes a very important challenge, especially under the severely changing climate conditions. An overhead power line exposed to high ice and rime loads has been considered. Using the finite element method (FEM), mechanical reliability of the distribution infrastructure was examined under various atmospheric conditions. Loads under the stressful conditions of rime, ice and wind were determined for the weakest section of the 30 kV overhead line, which consisted of concrete poles and ACSR conductors. SAIDI and SAIFI reliability indices and costs were determined for several variants of object reconstruction. The results allowed for determination of a solution relying on relocating the cables of all lateral branches and main line ice protection, through a system based on a weather-coordinated increase of the electrical load. To verify the solution proposed, a field experiment was conducted. The experiment confirmed the effectiveness of the solution proposed that appears to be universal. The paper is a result of synergic cooperation of two academic teams, i.e. a mechanical and electrical power engineering one, and the Distribution System Operator (DSO).
EN
The paper addresses the problem of placement of sectionalizing switches in medium voltage distribution networks. Proper placement of sectionalizing switches is one of the elements leading to higher power networks reliability. The methods of optimal allocation of such switches in a MV distribution network are presented in the paper. SAIDI was used as a criterion for the sectionalizing switches placement. For selecting optimum placements, three methods were used: brute force method, evolutionary algorithm and heuristic algorithm. The calculations were performed for a real MV network.
PL
W pracy przeanalizowany zostanie jeden z możliwych scenariuszy powstawania narażeń napięciowych, a mianowicie wystąpienie zjawiska przeskoku odwrotnego. W scenariuszu tym w wyniku wyładowania atmosferycznego do uziemionych elementów konstrukcyjnych linii może dojść do utraty wytrzymałości elektrycznej zastosowanego łańcucha izolatorów. Rezultatem pracy jest określenie charakterystycznych wartości szczytowych prądu wyładowania atmosferycznego IPOmin powyżej, której na układzie izolacyjnym dochodzi do zjawiska przeskoku odwrotnego. Obliczenia przeprowadzono na wybranych sylwetkach konstrukcji wsporczych (typu przelotowego), stosowanych w liniach o napięciu nominalnym 110 kV, 220 kV i 400 kV. Uwzględniane sylwetki wsporcze (serii SL24, C3, H52, M52, Y25 i Z52) różnią się między sobą pod względem m.in. geometrii zawieszenia przewodów i wysokości.
EN
Among the disturbances in the operation of the power system, one of the most important (from the point of view of e.g. insulation coordination or selection of clearances) are overvoltages caused by direct atmospheric discharge (lightning) to overhead power line structural elements. In the case of direct lightning, one possible scenarios of sources of these disturbance is considered: back flashover phenomena. In this case concerns the situation of loss of electrical strength of the insulation system used. The result of the work is to determine the peak value of lightning current IPOmin, above which in the insulation system is lost electric strength. Calculation were carried out on selected profiles of support structures, dedicated to electrical power system with rated voltage of 110 kV, 220 kV and 400 kV (single-circuit and double-circuit three phase line were considered) - 110 kV (SL24, C3), 220 kV (H52, M52) and 400 kV (Y25, Z52). The support structures differing in the geometry of the wire hanging and their heights. All simulation cases were performed using The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
PL
Niezawodność systemów przesyłu i rozdziału energii elektrycznej zależy od postępów w koordynacji izolacji, która jest uwarunkowana między innymi przez zwiększenie możliwości identyfikacji narażeń napięciowych układów izolacyjnych. W pracy przeanalizowany zostanie jeden z możliwych scenariuszy narażeń napięciowych w napowietrznych liniach elektroenergetycznych, a mianowicie zawodność ochrony odgromowej. Rezultatem pracy jest określenie charakterystycznych wartości szczytowych prądu wyładowania atmosferycznego IBUmax, powyżej których ochrona odgromowa jest zachowana. Obliczenia przeprowadzono na wybranych sylwetkach konstrukcji wsporczych (typu przelotowego oraz wykonania specjalnego), stosowanych w liniach o napięciu nominalnym 110 kV. Uwzględniane sylwetki wsporcze (serii B2, C3, P94, Src, Orc i P88) różnią się pod względem geometrii zawieszenia przewodów, wysokości oraz rodzaju wykonania.
EN
The reliability of electrical power transmission and distribution systems depends on progress in the coordination of insulation, which depends, among other things, on increasing the ability to identify risks of overvoltage in insulation systems. The purpose of the paper is to present the problems related to one of the possible scenarios of overvoltages caused by atmospheric discharge, which is shielding failure. In this scenario, despite the ground wires used, it is possible to direct hit into the phase conductor by atmospheric discharge. The result of the work is the determination of characteristic peak values of the lightning current IBUmax, above which lightning protection is maintained. Calculations were carried out on selected profiles of tower (lattice and tubular), used in overhead power lines with rated voltage of 110 kV and taking into account two types of approaches (base on distance of decision or on active distance). The tower profiles (B2, C3, P94, Src, Orc and P88 series) differ in terms of conductors suspension geometry, height and type of construction.
PL
W referacie dokonano analizy wpływu estymacji obciążeń sieci średniego napięcia na rozmieszczenie źródeł mocy biernej w sieciach dystrybucyjnych. W celu estymacji obciążeń sieci SN wykorzystywana jest informacja o całkowitym obciążeniu linii SN zarejestrowanym w stacji zasilającej. Pierwsza metoda zakłada rozdział obciążenia, zarejestrowanego w stacji zasilającej, pomiędzy stacje SN/nn proporcjonalnie do mocy znamionowych ich transformatorów. Druga metoda zakłada losowy rozdział obciążenia pomiędzy poszczególne stacje SN/nn. Obliczenia wykonano z zastosowaniem programu komputerowego dedykowanego do iteracyjnych obliczeń rozpływowych. W referacie ponadto omawia się wyniki obliczeń oraz przeprowadza analizę celowości stosowania przyjętych metod obliczeniowych.
EN
The paper concerns the effect of load estimation of location reactive power sources in MV distribution networks. In order to estimate the MV network load, information about the total load of the MV line registered in the power station is used. The first method assumes the distribution of the load, registered in the power station, between the MV / LV stations in proportion to the rated power of their transformers. The second method assumes the random distribution of the load between individual MV / LV stations. Additionally, the balancing of the supply node (the sum of load power and losses on network elements is equal to the power flows into the network) is used in described methods. The calculations were performed using the dedicated computer programme for iterative flow computations. The paper also discusses the results of calculations and the analysis of the desirability of using the applied calculation methods is performed.
PL
W układach elektroenergetycznych elementami najbardziej narażonymi na wyładowania atmosferyczne, ze względu na swoją rozległość, są linie napowietrzne. Przy analizie tego typu narażeń linii elektroenergetycznych rozważa się m.in. uderzenie bezpośrednie pioruna w przewód fazowy. W tym przypadku opierając się jedynie na geometrii zawieszenia przewodów (fazowych i odgromowych) na analizowanej konstrukcji wsporczej można określić maksymalną wartość szczytową prądu pioruna, który może uderzyć w przewód fazowy. W referacie umieszczono wyniki analizy zawodności ochrony odgromowej dla sylwetek konstrukcji wsporczych, typu przelotowego, stosowanych w liniach o napięciu znamionowym 110 kV: serii B2 i serii SL24. W przeprowadzonych analizach uwzględniono różne podejścia wiążące wartość szczytową prądu wyładowania atmosferycznego z odległością do elementów konstrukcji wsporczej, jak i do powierzchni ziemi.
EN
In the electrical power systems, the most exposed to atmospheric discharges, due to their size, are overhead lines. When analyzing this type of electricity line exposure, consideration is direct lightning strike into the phase conductor. In this case, based only on the wire suspension geometry (phases and grounding) on the analyzed support structure, it is possible to determine the maximum peak value of the lightning current that can hit the phase conductor. The paper presents the results of the analysis of the shielding failure for profiles of support structures, used in lines with a rated voltage of 110 kV: series B2 and series SL24. The analyzes carried out took into account various approaches binding the peak value of the atmospheric discharge with the distance to the structural elements of the supporting structure as well as to the surface of the ground.
PL
Dokładne wyznaczenie strat mocy wymaga przeprowadzenia iteracyjnych obliczeń rozpływowych. Dane do obliczeń obejmują m.in. wartości obciążeń węzłów odbiorczych sieci. W przypadku sieci rozdzielczych średnich napięć te dane nie są znane i niezbędne jest zastosowanie metod umożliwiających ich estymację. W referacie przedstawia się dwie metody estymacji obciążeń sieci średniego napięcia. Pierwsza metoda zakłada rozdział obciążenia, zarejestrowanego w stacji zasilającej, pomiędzy stacje SN/nn proporcjonalnie do mocy znamionowych ich transformatorów. Druga metoda zakłada losowy rozdział obciążenia pomiędzy poszczególne stacje SN/nn. Dla testowej sieci rozdzielczej wykonano obliczenia z zastosowaniem opisanych metod oraz przedstawiono i omówiono wyniki obliczeń.
EN
The calculation of power losses usually requires iterative flow calculations. Data for calculation include, among other things, load values of the network receiving nodes. In the case of medium voltage (MV) distribution networks, these data are known not known and estimation methods are necessary. Two methods of estimating MV network loads are presented in the paper: The first method involves distribution of the total load, measured in the power supply station, between MV/LV stations in proportion to the rated power of their transformers. The second method assumes a random distribution of the total load between MV/LV transformer stations. The paper presents the results of calculations for the test distribution network (IEEE69).
PL
W artykule przedstawiono analizę, mającą na celu określenie możliwości przekroczenia obciążalności zwarciowej żył powrotnych kabli średniego napięcia, podczas zwarć podwójnych z ziemią. Przeprowadzona analiza bazowała na danych statystycznych rzeczywistej sieci średniego napięcia. Zaprezentowane wyniki obliczeń obejmują między innymi prawdopodobieństwa przekroczenia obciążalności znamionowej żył powrotnych kabli oraz liczby przekroczeń tej wartości na jednostkę długości linii kablowych, mogących wystąpić w określonym czasie.
EN
The article presents an analysis aimed to identify the possibility of exceeding the short-circuit capacity of return conductors of medium voltage cables, during the two-phase-to-earth faults. The analysis was based on actual statistical data of medium voltage power network. Presented results of the calculations include, among others, the possibility of exceeding the rated capacity of return conductors of cables and the number of exceedances of this value per unit length of cable lines, which may occur within a specific time.
EN
The addition of a new source of active power to an electric power distribution network alters its operation conditions. The effect of such changes depends on the power of the additional source, its location in the network as well as its type. In the paper the influence of the active power source on the selected parameters of the operations of the distribution network – such as the active power losses and voltage levels – is presented. Also, the influence of the level of power of the additional source and the level of the network’s load on the location of tie points is considered.
PL
Instalacja dodatkowego źródła mocy czynnej w elektroenergetycznej sieci rozdzielczej zmienia warunki jej pracy. Efekt zmian zależy od mocy dodatkowego źródła, miejsca jego lokalizacji w sieci oraz rodzaju przyłączanego źródła. W pracy analizuje się wpływ źródła mocy czynnej na wybrane parametry pracy sieci dystrybucyjnej takie jak straty mocy czynnej i poziomy napięć. Dokonano analizy wpływu mocy przyłączanego źródła i poziomu obciążenia sieci na lokalizację stałych punktów podziału sieci.
PL
Wartości prądów płynących w uziemieniach słupów elektroenergetycznych linii napowietrznych podczas zwarć jednofazowych są istotne dla oceny zagrożenia porażeniowego w otoczeniu linii. W artykule przedstawiono dwa modele do obliczania rozpływu tych prądów. Pierwszy z nich to dokładny model wielofazowy, natomiast drugi jest jego uproszczeniem do modelu jednofazowego. Przedstawiono również wyniki obliczeń wartości prądów płynących w uziemieniach słupów linii 110 kV podczas zwarć jednofazowych.
EN
The values of the currents flowing in earthing system of overhead line towers during single-phase faults are important for assessing the risk of electric shock in neighborhood of the line. The article presents two models to calculate these currents. The first is accurate, multiphase model, while the second is its simplification to a single-phase model. Results of calculations of currents flowing in towers earthing system during singlephase faults in 110 kV overhead line are also presented in the article.
PL
W artykule przedstawiono modele probabilistyczne zdarzeń, będących przyczyną powstawania przepięć łączeniowych, determinujących wymiarowanie odstępów izolacyjnych w liniach napowietrznych. Badano zarówno przepięcia występujące w czasie załączania linii jak i przy samoczynnym ponownym załączaniu. Otrzymane rozkłady statystyczne wykorzystano do wymiarowania odstępów powietrznych izolacji faza-ziemia oraz faza-faza. Analizy przeprowadzono zarówno z uwzględnieniem, jak i pominięciem ochrony przepięciowej rozważanej linii.
EN
The article presents the probabilistic models of events, being the cause of switching overvoltages, determining the dimensioning of insulation gaps in the overhead lines. Values of overvoltages occurring during switching on the lines and occurring during their automatic reclosing were calculated. The statistical distributions of overvoltages, being the result of calculation, were used for dimensioning of phase-to-ground and phase-to-phase air gaps insulation. Analyses were performed both with and without taking into account the line surge protection.
PL
W artykule przedstawiono złożoność problematyki analizy stanów nieustalonych napięć pojawiających się w układzie elektroenergetycznym wskutek bezpośrednich wyładowań piorunowych do elementów konstrukcyjnych linii napowietrznej. Analiza zakłóceń eksploatacyjnych wywołanych wyładowaniami piorunowymi dotyczy układu elektroenergetycznego o napięciu znamionowym 110 kV. Przedstawione wyniki stanowią przykład analizy narażeń napięciowych układów izolacyjnych aparatów stacyjnych z uwzględnieniem rożnych wariantów zastosowanej ochrony przepięciowej w analizowanej stacji. Symulacje opisywanego zakłócenia zostały dokonane przy pomocy programu The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
EN
This paper deals with analyzing specific transient states of voltages in electric power systems of high voltages. The paper presents the results of the analysis of operational disturbances caused by lightning discharges in 110 kV power system. Furthermore, the analysis results of lightning surges as well as the optimization results of a surge protection system installed in a 110 kV substation are presented. A model of an electric power system (overhead lines and substation) and all simulations were performed using computer software Electromagnetic Transients Program-Alternative Transients Program (EMTP-ATP). This model is based on a set of appropriately connected elements (distributed and lumped parameter elements) taking wave effects and nonlinear effects into consideration.
PL
W artykule przedstawiono problematykę statystycznej analizy optymalnego przekroju żyły powrotnej w sieciach kablowych, przy uwzględnieniu danych rzeczywistych sieci rozdzielczych o znamionowym napięciu: 6 kV, 15 kV, 20 kV i 30kV. Przedstawiona analiza ma na celu określenie poziomu zagrożenia żył powrotnych kabli średniego napięcia wskutek przekroczenia ich obciążalności prądem zwarciowych. Analizy przekroczeń obciążalności zwarciowej żył powrotnych dokonano przy wykorzystaniu programów: Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP) oraz Statgraphics, wykorzystanych odpowiednio przy modelowaniu komputerowym zwarć podwójnych oraz przy analizie optymalizacji statystycznej doboru przekroju żyły powrotnej.
EN
This paper presents the problem of statistical analysis of the optimum cross-section of the return conductor, taking into account the actual data of the distribution network. The aim of this study was to determine the level of risk of venous return conductors as a result of exceeding their permissible load short-circuit current. Analysis was made using programs: The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP) and Statgraphics, appropriately to computer modeling of double faults and the analysis of statistical optimization.
EN
This paper presents issues concerning the implementation of Smart Grid solutions in a real distribution network. The main components possible to quick implementation were presented. Realization of these ideas should bring tangible benefi ts to both customers and distribution system operators. Moreover the paper shows selected research results which examine proposed solutions in area of improving supply reliability and reducing energy losses in analysed network.
PL
W  artykule przedstawiono zagadnienia dotyczące wdrażania rozwiązań typu Smart Grid w  konkretnej sieci rozdzielczej. Omówiono główne systemy, możliwe do szybkiego wdrożenia, których zastosowanie przyniesie wymierne korzyści zarówno odbiorcom energii elektrycznej, jak i operatorowi sieci. Przedstawiono też wybrane wyniki badań, których celem było sprawdzenie proponowanych rozwiązań pod kątem możliwości osiągnięcia założonych celów, a w szczególności poprawy pewności zasilania oraz ograniczenia strat energii w analizowanej sieci.
PL
Artykuł dotyczy analizy sieci elektroenergetycznych średnich napięć, która przeprowadzona została w celu rozpoznania warunków eksploatacji w aspekcie występowania ferrorezonansu. Zaprezentowano udokumentowany przypadek wystąpienia ferrorezonansu, który doprowadził do uszkodzenia przekładników napięciowych. Analizę przeprowadzono na podstawie opracowanego modelu układu sieci oraz wyników badań symulacyjnych, mających na celu określenie warunków i skutków występowania ferrorezonansu, jak i sposobów jego eliminacji.
EN
The article reports a medium voltage power grid analysis carried out to identify the grid’s operating conditions in the aspect of ferroresonance occurrence. A documented ferroresonance instance is presented, which led to the voltage transformers’ damage. The analysis was based on an original grid system model and on results of simulation studies designed to determine the ferroresonance occurrence conditions and consequences, as well as means to eliminate it.
PL
Artykuł dotyczy analizy wpływu zastosowanego modelu konstrukcji wsporczej na poziom przepięć atmosferycznych w układach izolacyjnych napowietrznych linii elektroenergetycznych o napięciu 110 kV i wyższym. Symulacje obejmują trzy rodzaje modeli konstrukcji wsporczych, które opracowano dla konstrukcji typu: B2P (110 kV, linia jednotorowa), H52P (220 kV, linia jednotorowa) i Z52P (400 kV, linia dwutorowa). Podczas analizy założono, że uderzenie pioruna następuje w konstrukcję wsporczą powodując przeskok odwrotny. Symulacje przeprowadzone zostały przy pomocy programu The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
EN
In this article analysis of tower model influence on overvoltages in high voltage overhead lines are presented. Simulations involved three types of towers: B2P (110 kV, single system line), H52P (220 kV, single system line) and Z52P (400 kV, double system line). During the analysis considered back flashover phenomenon as an result of lightning strike to overhead line. All simulation cases are made in simulation software The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
PL
Artykuł dotyczy analizy wpływu kształtu prądu pioruna na wielkość przepięć atmosferycznych w układach izolacyjnych napowietrznych linii o napięciu 110 kV. W analizie rozważano trzy kształty prądu wyładowczego do linii napowietrznej: prostokątny, trójkątny oraz z wklęsłym czołem, jak również dwa przypadki narażeń linii elektroenergetycznych (uderzenia bezpośredniego w przewód fazowy oraz tzw. przeskok odwrotny). Symulacje przeprowadzone zostały przy pomocy programu The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
EN
In article analysis of influence of lightning current shapes on overvoltages in high voltage overhead lines are presented. Simulations involved three shapes of lightning current (rectangular shape, triangular shape and current with concave face) and two cases of atmospheric discharges (direct impact and so-called back flashover). All simulation cases are made in simulation software The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
PL
Artykuł dotyczy modelowania i analizy przeskoku odwrotnego w układach izolacyjnych napowietrznych linii o napięciu 110 kV i wySszym. Przedstawione wyniki symulacji efektów falowych, wywołanych uderzeniem pioruna w rozpatrywane konstrukcje wsporcze mają na celu określenie warunków i skutków występowania przeskoku odwrotnego. Analiza obejmuje trzy typy konstrukcji wsporczych: B2P (110 kV), H52P (220 kV) oraz Y25P (400 kV). Symulacje przeprowadzone zostały przy pomocy programu Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
EN
In article modelling and analysis of back flashover in the overhead line insulation with a voltage of 110 kV and higher are presented. Back flashover across line isolators is one of the main causes of transmission line outages, even when ground wires are used. The simulation of this phenomenon can be useful to determine the consequences of the occurrence of back flashover. Simulations involved three types of tower: B2P (110 kV), H52P (220 kV) and Y25P (400 kV). All simulation cases are made in simulation software The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
PL
W artykule przedstawiono model sieci przesyłowej o napięciu znamionowym 150 kV, zasilającej miasto Aalborg (Dania) oraz wyniki symulacji efektów falowych, wywołanych uderzeniem pioruna w przewód fazowy linii. Symulacje przeprowadzone zostały przy pomocy programu The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).
EN
In this paper a 150 kV transmission electrical power system in Aalborg model and simulation results of surge hazards generated by lightning stroke to the phase conductor of overhead line are presented. Ali simulation cases are made in simulation software The Electromagnetic Transients Program - Alternative Transients Program (EMTP-ATP).