Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The aim of the presented case study analysis was to present the possibilities of using the SenseWear PRO3 Armband mobile monitor in the assessment of physical activities. During the measurement, the SenseWear PRO3 Armband recorded the following parameters: total energy expenditure [kcal], average METs (for the whole analyzed period) [-], number of steps [-], active energy expenditure [kcal], lying down duration [min], sleep duration [min], sedentary physical activity duration [min], physical activity duration [min], including moderate physical activity duration [min], vigorous physical activity duration [min] and very vigorous physical activity duration [min]. The results for chosen participant were analyzed – in various periods of time (for the 24 on-body hours session of wearing the SenseWear PRO3 Armband and the whole session), as well as for basic and broaden analysis. The graphical reports from the sessions were also presented. It was concluded that the SenseWear PRO3 Armband device is a valuable tool in everyday medical practice to specify the physical activity of individuals and to verify their declarations. For users, the SenseWear PRO3 Armband device is easy to handle, while measurement is not onerous and does not disturb typical activities
EN
Individual total energy expenditure may be calculated as a sum of basal energy requirement and energy expenditure associated with physical activity. Measurement of basal energy requirement is not often conducted in dietetic practice, but may be applied using indirect calorimetry. The aim of the analysis was to present the possibilities of using the Fitmate PRO monitor in the assessment of resting metabolic rate and basal energy expenditure with a method of indirect calorimetry in a group of 91 overweight and obese women in various age. The mean results of the resting metabolic rate measured with method of indirect calorimetry using the Fitmate PRO monitor did not differ in the age groups of overweight and obese women. The results of the resting metabolic rate measured with method of indirect calorimetry using the Fitmate PRO monitor were correlated with body mass, height, fat mass, muscle mass and waist circumference. The Fitmate PRO monitor may be a valuable tool in everyday dietetic practice to assess the basal energy expenditure with method of indirect calorimetry in a group of overweight and obese women.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.