Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The construction, performance, and applications of nitrate-selective electrode based on l,8-bis(salicyIaldiminato)-3,6-dioxaoctane Ni(II) complex as a carrier trapped in plasti-cized poly{ vinyl chloride) (PVC) matrix were described. The influence of membrane composition, pH, and potential interfering anions was investigated based on the response of the electrode. The electrode exhibited linear response with Nemstian slope of-58.7 š 0.7 mV per decade within the concentration range of nitrate ions of 8.0 x 10-6-1.0 mol L-1. The limit of detection was determined from the intersection of the extrapolated linear segments of the calibration plot, and equaled 8.0 x 10-6 -1.0 mol L-1. The response time of the electrode was < 15 s over the entire concentration range. The designed electrode could be used for at least three months without a significant potential drift. It exhibited good selectivity towards nitrate compared to other anions. It was applied as the indicator electrode in potentiometric determination of nitrate ions in real samples.
PL
Opisano konstrukcję, charakterystykę i zastosowania elektrody do oznaczania azotanów. Jako nośnik stosowano kompleks Ni(II) z l,8-bis(salicy!aldiminato)-3,6-dioksaoktanem w plastyfikowanym polichlorku winylu. Badano wpjyw składu membrany, pH i potencjalnie obecnych anionów na potencjał elektrody. Elektroda wykazuje nernstowskie nachylenie charakterystyki wynoszące-58,7 š 0,7 mV/dekade w zakresie stężeń 8.0 x l0-6-1.0. Granica wykrywalności wynzaczona na podstawie przecięcia liniowych odcinków krzywej kalibrowania wynosi 8.0 x 10-6 -1.0 mol L-1. Czas odpowiedzi elektrody w całym zakresie stężeń wynosi 15 s. Elektroda może być używana w ciągu co najmniej 3 miesięcy bez widocznej zmiany potencjału. Wykazuje dobrą selektywność wobec innych anionów. Elektroda została zastosowana do oznaczania azotanów w rzeczywistych próbkach.
2
Content available remote Solid phase extraction and flame atomic absorption determination of copper
EN
The Cu(II) was separated by solid phase extraction on octadecyl-bonded silica membrane disks modified with N,N'-bis(salicylidene) ethylenediamine (SED) followed by elution and flame atomic absorption spectrometric detection and applied as a separation and detection method for copper(II) in water. Extraction efficiency and the influence of sample matrix, flow-rate, pH, and type and minimum amount of stripping acid were investigated. The maximum capacity of the membrane disks modified by 5 mg of SED was found to be 649š15 ug of copper. The limit of detection of proposed method is 0.04 ngmL(-1).
PL
Opracowano metodę wykrywania i oznaczania miedzi(II) w wodzie. Cu(II) wydzielano za pomocą ekstrakcji do fazy stałej na dysku C(18) modyfikowanym N,N'-bis(salicylideno)etyle-nodiaminą(SED), a następnie oznaczano metodą absorpcyjnej spektrometrii płomieniowej. Badano wpływ matrycy, pH oraz szybkość przepływu na wydajność ekstrakcji. Badano również wpływ rodzaju i ilości kwasu na proces wymywania miedzi z dysku. Maksymalna pojemność dysku modyfikowanego 5 mg SED wynosiła 649š 15 fig miedzi. Granica wykrywalności proponowanej metody wynosi 0.04 ng mL(-1).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.