Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Power electronic three-level AC-DC converters connecting a utility grid with DC supplies are widely used in renewable energy sources. For such distributed systems, the quality of energy is very important. Hence, control algorithms of an AC-DC converter have to provide not only a sinusoidal shape of grid current, but also stable operation during transient states in the grid, e.g. voltage dips or voltage unbalance. This paper deals with the problem of robustness of AC-DC control methods under disturbed grid voltage. Three modern predictive control algorithms are presented and investigated under grid voltage distortions. Experimental results from a laboratory test setup illustrating properties of the described methods are shown.
PL
W artykule przedstawiono sterowanie predykcyjne silnikiem synchronicznym z magnesami trwałymi, nazwane DTC-3V. Nowy regulator predykcyjny bazuje na kryterium minimalizacji uchybu regulacji momentu i strumienia. Sterowanie zostało zoptymalizowane zarówno w stanach statycznych, zapewniając wysoką dokładność regulacji, małe tętnienia momentu oraz stałą częstotliwość przełączeń, jak i dynamicznych, zapewniając dynamikę kształtowania momentu porównywalną z najszybszymi metodami nieliniowymi. Zaprezentowano założenia nowej metody oraz wyniki badań symulacyjnych i laboratoryjnych, potwierdzające poprawność przeprowadzonej analizy.
EN
In this article a new DTC-3V control method of PMSM with new predictive controller is presented. The method is based on torque and flux error vector minimization criteria. The proposed method was optimized for both static and dynamic states. In static states it ensures high performance, reduction of the torque ripples and constant switching frequency. In dynamic states DTC-3V method provides the fastest torque response, similar to non linear methods. The correctness of the analysis and main assumptions as well as the expected final results have been verified in simulation and laboratory investigation.
PL
W artykule przedstawiono sterowanie silnikiem synchronicznym z magnesami trwałymi typu FOC z predykcyjnym regulatorem prądu. Regulator bazuje na kryterium minimalizacji uchybu regulacji składowych prądu silnika, zapewnia wysoką dokładność w stanach statycznych, małe tętnienia momentu, stałą częstotliwość przełączeń, przy dynamice kształtowania momentu porównywalne z najszybszymi metodami nieliniowymi. Zaprezentowano założenia nowej metody oraz wyniki badań laboratoryjnych, potwierdzające poprawność przeprowadzonej analizy.
EN
In this article a new Field Oriented Control method of PMSM with predictive current controller is presented. The method is based on current error vector minimization criteria. The proposed method (called FOC-P) ensure the high performance in static states, reduction of the torque ripples, and constant switching frequency without deterioration of the dynamic properties of non linear methods. The correctness of the analysis and main assumptions as well as the expected final results have been verified in laboratory investigation.
PL
W artykule przedstawiono możliwości zastosowania predykcyjnego algorytmu regulacji prądu w trójfazowym przekształtniku AC/DC, pracującym jako trójgałęziowy filtr aktywny. Algorytm bazuje na pryncypiach metody DPC (Direct Power Control). Zastosowanie w nieliniowym algorytmie modulacji wektorowej umożliwia minimalizację uchybu wektora prądu w pojedynczym okresie próbkowania procesora, zmniejszenie tętnień prądu sieciowego, zapewnienia stałą częstotliwość przełączeń przy bardzo dobrych właściwościach dynamicznych układu, co umożliwia w prosty sposób wyeliminowanie harmonicznych związanych z przełączaniem tranzystorów przy użyciu rezonansowego filtru LC. Przedstawiono wyniki badań symulacyjnych, potwierdzające poprawność przeprowadzonej analizy.
EN
In This article a new, predictive control method of Active Power Filter are presented. The method is based on the Direct Power Control algorithm and the current error vector minimization criteria. This non-linear method with vector modulation ensures constant switching frequency and grid current error vector minimization without deterioration of very good dynamic properties. Constant switching frequency provides a simple way to eliminate (using LC passive filter) the current higher harmonics associated with switching transistors. The analysis correctness is acknowledged by the simulation investigation results.
5
Content available remote Nowy algorytm bezpośredniej regulacji momentu i strumienia maszyny indukcyjnej
PL
W artykule przedstawiono propozycję nowego, predykcyjnego algorytmu sterowania trójfazowym przekształtnikiem DC/AC zasilającym silnik indukcyjny. Algorytm bazuje na pryncypiach metody DTC (Direct Torque Control). Dzięki zastosowaniu modulacji wektorowej możliwe jest całkowite zredukowanie uchybów momentu i strumienia w pojedynczym okresie próbkowania procesora, zmniejszenie tętnień momentu elektromagnetycznego i zapewnienie stałej częstotliwości przełączeń. Przedstawiono wyniki badań symulacyjnych, potwierdzające poprawność przeprowadzonej analizy.
EN
In this article a new predictive control method of DC/AC inverter fed induction motor is presented. The new method is based on the Direct Torque Control algorithm and the torque and flux error vector minimization criteria. The proposed method ensures the torque and flux error vector minimization, reduction of the torque ripples, and constant switching frequency. The analysis correctness is acknowledged by the simulation investigation results.
6
Content available remote Predykcyjne algorytmy sterowania trójfazowym przekształtnikiem AC/DC
PL
Dzięki zastosowaniu dodatkowej modulacji wektorowej możliwe jest całkowite zredukowanie uchybu wektora prądu w pojedynczym okresie próbkowania procesora, zmniejszenie tętnień prądu sieciowego i zapewnienie stałej częstotliwości przełączeń. Przedstawiono wyniki badań symulacyjnych, potwierdzające poprawność przeprowadzonej analizy.
EN
W artykule przedstawiono propozycję nowego, predykcyjnego algorytmu sterowania trójfazowym przekształtnikiem AC/DC. Algorytm bazuje na pryncypiach metody DPC (Direct Power Control). In This article a new, predictive control methods of the AC/DC inverter are presented. Both methods are based on the Direct Power Control algorithm and the current error vector minimization criteria. The main assumption of the predictive DPC-2V-[delta]and DPC-2V-[delta]algorithms are presented. The analysis correctness is acknowledged by the simulation investigation results.
PL
W artykule przedstawiono nową, zmodyfikowaną metodę typu DTC sterowania silnikiem synchronicznym z magnesami trwałymi, nazwaną DTC-3A, opartą na nowym podziale pola uchybu regulacji momentu i strumienia. Zaprezentowano założenia nowej metody, sposób wyznaczenia nowego podziału pola uchybu oraz zasadę działania sterowania wg metody DTC-3A. Przedstawiono także wyniki badań symulacyjnych, potwierdzające poprawność przeprowadzonej analizy.
EN
In This article a new, modified DTC control method of PMSM, called DTC-3A, is presented. In this method a new, optimal error area is proposed. The main assumption of DTC-3A method and the way of construction of the new error area is presented. The analysis correctness is acknowledged by the simulation investigation results.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.