Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The sodium silicate sands hardened by microwave have the advantages of high strength, fast hardening speed and low residual strength with the lower addition of sodium silicate. However, the sodium ion in the sands will absorb moisture from the atmosphere, which would lead to lower storing strength, so the protection of a bonding bridge of sodium silicate between the sands is crucial. Methyl silicone oil is a cheap hydrophobic industrial raw material. The influence of the addition amount of methyl silicone oil modifier on compressive strength and moisture absorption of sodium silicate sands was studied in this work. The microscopic analysis of modified before and after sodium silicate sands has been carried on employing scanning electron microscopy(SEM) and energy spectrum analysis(EDS). The results showed that the strength of modified sodium silicate sands was significantly higher than that of unmodified sodium silicate sands, and the best addition of methyl silicone oil in the quantity of sodium silicate was 15%. It was also found that the bonding bridge of modified sodium silicate sands was the density and the adhesive film was smooth, and the methyl silicone oil was completely covered on the surface of the sodium silicate bonding bridge to protect it.
EN
Sodium silicate is one of the most successful inorganic binder. Along with the broad application of sodium silicate for domestic and industrial purposes, the composition analysis, include modulus (m), ratio of SiO2:Na2O, Na2O%, SiO2%, and solid-containing content, is important for the products strength and service life. However, it is perplexing to operate, inefficient and low precision for traditional standard testing method of these parameters. In this study, an automatic measurement system of sodium silicate composition analysis, with the potential electrode for potentiometer titration, micro-controller, PCB, heater, stirrer, printer and micro peristaltic pump, was developed according to the determine method principle. The end-points of pH value in the two titrating steps, first was 4.3 and second was 6.0, were set in the micro-controller to control the reaction in the processing of the sodium silicate composition analysis. And all the potential signals of the pH electrode were transited in the special PCB for the micro-controller.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.