Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A simple, rapid, and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of zinc pyrithione (ZnPT) and pyrithione (PT) in shampoos. The method consisted of a liquid–liquid extraction for sample preparation. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode via the positive electrospray ionization interface. A linear regression (weighted 1/x) was used to fit calibration curves over the concentration range of 50–2000 ng/mL for both ZnPT and PT. Excellent linearity (r 2 ≥ 0.9996) was achieved for all. The method was validated and found to be accurate (95.9–108.2% for ZnPT and 94.9–110.4% for PT), precise, and selective. Analytes in shampoos were found to be stable in the autosampler (6 °C for 6 h), in room temperature (for 6 h), and after three freeze–thaw cycles, and recovery of analytes was reproducible (90.8–94.6% for ZnPT and 90.2–96.3% for PT).
EN
Fast water flow facilitates ferrous ion transport leading to flow accelerated corrosion (FAC) of carbon steel and the possibility of a large accident through a failure of a secondary pipe in a nuclear power plant. Ion transport is directly linked to oxide properties such as the thickness, chemical composition and porosity. This work deals with a precise observation of the cross section of the corroded specimen focusing on an oxide passivity and its thickness using SEM (scanning electron microscope) and TEM (transmission electron microscope) as well as an apparent weight loss and a surface observation for the specimens corroded using a rotating cylindrical electrode autoclave system in pure water of pH 7 at 150°C having dissolved oxygen below 1 ppb within a flow rate range of 0 to 10 m/s. The Cr content in steel was changed from 0.02 to 2.4 wt%. Increasing the Cr content in the alloy, the FAC rate and oxide thickness decreased. The oxide porosity tends to decrease with the Cr content and immersion time owing to the development of Cr containing oxide. The oxidation behavior is not changed with the immersion time.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.