An extensive methodology for analyzing the impact of catchment and sewer network retention on drainage system operating conditions during hydraulic overloading is presented. To evaluate the performance of the sewer system and identify the need for repair actions, logistic regression models were developed to predict the unit flooding volume and manhole overflowing. An advanced sensitivity analysis was performed to determine the key parameters (retention and roughness of impervious and pervious areas as well as sewer channel retention) conditioning the reduction of uncertainty in the simulation results and ensuring the assumed hydraulic effect. A coefficient expressing the quotient of the duration of rainfall conditioning the exceedance of the limits of the unit flooding volume (13 m3·ha−1) as well as the degree of overflowed manholes (0.32) was determined, allowing the determination of the key performance criterion of the sewer network to take corrective action depending on field and channel retention. It was shown that the catchment area retention had the key influence on the conditions of sewer operation and the probability of remedial work. Increasing the rainfall duration led to a decrease in sensitivity coefficients with respect to the identified parameters of the SWMM model, which is important when selecting rainfall events for the calibration and validation sets. The usefulness of the developed methodology was demonstrated at the stage of building mechanistic models, which is of significance when planning field studies.
The paper presents the results of studies on local resistance coefficients (ζ). The study used pipe aerators with filling made according to the Polish patent PL235924. The hydraulic investigations were performed in real working conditions of a water treatment plant in a testing rig built in the Scientific and Research Water Station of the Warsaw University of Life Sciences (SGGW). The investigation encompassed two plastic pipe aerators of an internal diameter 101.6 and 147.6 mm with steel Białecki rings of 12 and 25 mm in diameter. Measurements of pressure difference (Δp) in the investigated aerators were performed at volumetric water flows (Q) selected from the range 2-20 m3∙h-1 with the interval 2 m3∙s-1. The values of ζ were determined according to the PN-EN 1267:2012 standard. The investigation showed that the ζ depends both on an internal diameter of the plastic pipe aerator and the diameter of Białecki steel rings. The values of ζ increase with a decrease of the internal diameter of the pipe aerator and a decrease of the ring diameter.
The objective of this experimental study was to examine whether an assisting layer of lightweight expanded clay aggregate (LECA) of the granulation 1-4 mm, introduced into a subsoil, is able to improve an efficiency of removal of total nitrogen and total phosphorus from domestic wastewater. In the investigations, an assisting 0.10 and 0.20 m thick LECA layer was applied. It has been observed that the effectiveness of removal of total suspended solids (TSS), total nitrogen and total phosphorus from wastewater as well as the level of biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) is in accordance with the Polish standards on wastewater disposal into grounds and surface water. The performed experiments showed that the effectiveness of raw wastewater purification for the medium sand soil bed with the 0.20 m thick assisting LECA layer is higher than for the 0.10 m thick assisting layer. In the medium sand soil bed with the 0.20 m thick assisting LECA layer, the removal efficiency regarding total nitrogen increased by 20.6%, total phosphorus by 5.2%, ammonium nitrogen by 8.8% and TSS by 5.3%, and reduction efficiency regarding BOD5 increased by 1.7% and COD by 2.3% with relation to the 0.10 m thick assisting LECA layer (all percentages - in average). The results of the experiment showed that the LECA with the granulation 1-4 mm can be used to assist in removal of total nitrogen and total phosphorus from wastewater with application of infiltration drainage.
Przedmiotem przeprowadzonych badań technologicznych był zaprojektowany prototyp oddzielacza cieczy lekkich (własne rozwiązanie producenta krajowego) – urządzenia powszechnie stosowanego w inżynierii sanitarnej do usuwania (podczyszczania) ze ścieków węglowodorów ropopochodnych. Warunkiem dopuszczenia urządzenia do stosowania go w praktyce inżynierskiej w instalacjach kanalizacyjnych jest uzyskanie odpowiednich pozwoleń. W tym celu na potrzeby producenta zostały wykonane odpowiednie badania oddzielacza na przygotowanym stanowisku doświadczalnym, zgodnie z obowiązującymi wytycznymi (normą). Zasadniczym celem była ocena efektywności usuwania (podczyszczania) węglowodorów ropopochodnych przez prototyp oddzielacza, w którym zastosowany został system podczyszczania w postaci lamelowego pakietu zaprojektowanego na przepływ nominalny Q = 1,5 l/s, oraz zaprojektowanego przez producenta (własna koncepcja) zbiorczego układu odpływowego ścieków z urządzenia. Dodatkowo określono sprawność oddzielacza przy zmiennym przeciążaniu hydraulicznym oraz sprawdzono odporność urządzenia na wymywanie zgromadzonej objętości węglowodorów ropopochodnych przy przepływie maksymalnym (zaprojektowany na pięciokrotne zwiększenie przepływu nominalnego). Uzyskane wyniki z przeprowadzonych badań technologicznych pozwoliły wykazać, czy zaprojektowany prototyp (koncepcja producenta) oddzielacza został zaprojektowany prawidłowo, spełniając wymagania określone w obowiązujących przepisach oraz dodatkowo wybranych kryteriach technologicznych.
EN
The subject of conducted technological research was the designed prototype of a light liquids separator (own solution devised by a domestic manufacturer). The device is commonly used in sanitary engineering to remove (pretreat) petroleum hydrocarbons from wastewater. Approval of the device for use in engineering practice in sewerage systems necessitates obtaining the relevant permits. For this purpose, appropriate tests of the separator were carried out on a prepared test bench for needs of the manufacturer, in accordance with the applicable guidelines (standard). The main objective was to evaluate the efficiency of removal (sub-treatment) of petroleum hydrocarbons by the prototype separator, in which the sub-treatment system was applied in the form of a lamella package, designed for a nominal flow of Q = 1.5 l/s and the original drainage system of the device. Additionally, the efficiency of the separator was determined at variable hydraulic overloading and the resistance of the device to washing out the accumulated volume of petroleum hydrocarbons at maximum flow (designed for five times the nominal flow) was controlled. The results obtained from the conducted technological tests allowed proving whether the designed prototype (producer’s concept) of the separator has been designed properly, in a way meeting the requirements specified in valid regulations and additionally selected technological criteria.
Przedstawiono wyniki obliczeń prognostycznych erozji koryta Wisły poniżej stopnia we Włocławku, w wariantach koryta niezabudowanego i realizacji stopni wodnych. Analizę przeprowadzono dla odcinka długości 234.400 km poniżej stopnia we Włocławku. Obliczenia prognostyczne deformacji koryta wykonano jednowymiarowym modelem hydrodynamicznym MIKE 11. Do obliczeń natężenia ruchu rumowiska wleczonego wybrano zależność Meyer Peter i Mullera. Zabudowa koryta Wisły stopniami spowoduje w korycie wzrost głębokości przepływu a w następstwie tego, zmniejszenie jej prędkości o ok. 10-15% przy przepływach maksymalnych i o ok. 50-60% przy przepływach średnich i niskich.
EN
The article presents the simulations of the Vistula riverbed erosion downstream of the Włocławek dam for two variants: with and without downstream dams. The analysis covers a section of 234.400 km downstream of the Włocławek dam. The simulations of the riverbed deformation were made using the one-dimensional hydrodynamic MIKE 11 model. To identify the intensity of the bed load transport, the authors used the Meyer-Peter and Muller formula. Construction of dams on Vistula will result in an increased flow depth and, as a consequence, in the river being slowed down by ca. 10-15% at maximum flows and 50-60% at medium and low flows.
Celem pracy było opracowanie innowacyjnych urządzeń służących do pomiaru i regulacji natężenia przepływu wody w systemach nawodnień podsiąkowych. Są to: zasuwa dwudzielna z przelewem prostokątnym do pomiaru i regulacji natężenia przepływu wody, zasuwa dwudzielna z przelewem trójkątnym do pomiaru i regulacji natężenia przepływu wody, zestaw przelewów do regulacji piętrzenia oraz pomiaru i regulacji przepływu wody na przepustozastawce oraz regulator piętrzenia wody w rowie. Praca powstała na podstawie wiedzy eksperckiej, studium literatury oraz wizji terenowych. Opracowane prototypowe urządzenia charakteryzują się dużą funkcjonalnością, gdyż mogą być instalowane na istniejących piętrzących budowlach melioracyjnych oraz służą nie tylko do pomiaru i regulacji natężenia przepływu wody, lecz również do regulacji piętrzenia wody w rowach odwadniająco-nawadniających na trwałych użytkach zielonych. Zainstalowane na obiektach nawodnień podsiąkowych prototypy będą badane pod kątem dokładności i zakresu prowadzonego pomiaru oraz ich użyteczności w warunkach odwodnień i nawodnień poprzez regulację położenia wody w rowach melioracyjnych.
EN
The aim of the work was to develop innovative devices for measuring and regulating flow rate in irrigation systems. These are: double-split gate with rectangular weir for measuring and regulating the water flow rate, double-split gate with triangular weir for measuring and regulating water flow rate, set of weirs for the damming regulation, measurement and regulation of water flow on the check designed for the maximum damming level and hinged gate in the pipeline. The work is based on the expertise, the study of literature and field vision. The developed prototype devices are characterized by high functionality, as they can be installed on existing irrigation structures and can be used not only to measure and regulate the water flow rate, but also to control water retention in drainage and irrigation ditches in agricultural areas. The prototypes installed in the sub-irrigation systems will be tested in terms of the accuracy and complexity of the measurements and usefulness in irrigation conditions for controlling the water retention in ditches.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.