Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
Porównano metody stosowane w Polsce i wybranych innych krajach. Wskazano na różnice w zasadach obliczania i wartościach współczynników długości wyboczeniowej słupów. Zamieszczono przykład obliczenia współczynników długości wyboczeniowych słupów na wybranych wielonawowych wielokondygnacyjnych ramach o węzłach nieprzesuwnych.
EN
The paper presents methods for calculating the effective length factors of reinforced concrete columns in non-sway frames, used in the United States of America, India and some European countries. Paper shows differences in approaches and values of the effective length factors of columns calculated according to those documents. The calculation was carried out on some examples of multi-span, multi-storey, non-sway frames.
PL
Badania eksperymentalne dotyczyły odkształceń żelbetowych belek zespolonych oraz monolitycznych belek kontrolnych, mających różne powierzchnie elementu podstawowego i różny stopień zbrojenia. Badania wykazały, że na nośność styku między betonami ułożonymi w różnych terminach ma wpływ nie tylko współczynnik zależny od szorstkości płaszczyzny zespolenia, ale również sztywność elementu.
EN
The aim of the research was to determine the strains in reinforced concrete beams poured in two stages. They were compared with the strains observed in control monolithic beams. The series of beams differs from each other according to the smoothness of the connection surface (smooth, rough and with indentations) and the reinforcement ratio. The research demonstrated that not only roughness of the surface has the influence on the shear capacity of the connection between concrete layers cast at different times, but also the stiffness of the element matters.
EN
Five cosmetics wastewater samples were treated by Dissolved Air Flotation (DAF) assisted by coagulation. Different aluminum based coagulants were used: (Al2(SO4)3, Al 1019, Al 3010, Al 3030, Al 3035, PAX 16 and PAX 19). The raw wastewater COD values were in the range 285–2124 mg/l. The efficiency of DAF depended on different coagulants and production profile of factory. COD removal was varied from 11.1 to 77.7%. The efficiency of coagulants was similar during treatment of particular sample. The best results were obtained with Al2(SO4)3 and for sample 5 – lotions and shampoos production. The wastewater from UV filter creams production (sample 4) was resistant to treatment by DAF regardless of used coagulant. HS-SPME-GC-MS analysis can be a confirmation of DAF effectiveness.
PL
Pięć próbek ścieków kosmetycznych zostało poddanych oczyszczaniu z wykorzystaniem flotacji ciśnieniowej wspomaganej koagulacją. Stosowano różne koagulanty na bazie glinu: Al2(SO4)3, Al 1019, Al 3010, Al 3030, Al 3035, PAX 16 and PAX 19. Wartość ChZT ścieków surowych była w zakresie 285–2124 mg/l. Skuteczność procesu flotacji ciśnieniowej była zależna od zastosowanego koagulantu i profilu produkcji fabryki kosmetyków. Skuteczność usunięcia wartości ChZT była w przedziale 11,1–77,7%. Skuteczność wszystkich koagulantów podczas oczyszczania każdej z próbek ścieków była podobna. Najlepsze rezultaty uzyskano z wykorzystaniem koagulantu Al2(SO4)3 , dla próbki 5 – ścieki pochodzące z produkcji szamponów i logionów. Ścieki z produkcji kremów z filtrem UV (próbka 4) były oporne na oczyszczanie za pomocą procesu flotacji ciśnieniowej, niezależnie od zastosowanego koagulantu. Zastosowana analiza HS-SPME-GC-MS potwierdziła skuteczność oczyszczania z wykorzystaniem flotacji ciśnieniowej.
4
Content available remote Charakterystyka ścieków kosmetycznych
PL
W pracy przedstawiono wyniki badań fizykochemicznych 20 próbek ścieków kosmetycznych. Określono wartości głównych parametrów zanieczyszczeń normowanych w ściekach. Na podstawie otrzymanych wyników badań stwierdzono, iż charakteryzują się dużą zmiennością, zależną od profilu produkcji. Różnice w oznaczonych wartościach poszczególnych parametrów w próbkach ścieków pobranych w różnym czasie w jednym zakładzie produkcyjnym wynoszą niemal trzy rzędy wielkości. Z tego względu niezmiernie ważne jest wielokrotne badanie właściwości ścieków kosmetycznych przed podjęciem decyzji dotyczącej technologii ich oczyszczania.
EN
The results of physicochemical analysis of 20 cosmetic wastewater samples were shown. The values of wastewater parameters were determined. Results show, that cosmetic wastewater are characterized by a strong variability, clearly dependent on the production profile. Differences between the values of key parameters ranged nearly three orders of magnitude. Because of the significant difference in the input parameters, wastewater treatment technology must have a very high flexibility.
EN
In this study the coagulation process of five cosmetics wastewater types has been investigated. All samples were collected from big cosmetic factory in Poland. Due to changeable production profile, also significant changeability of the wastewater composition and the concentration of pollutants were observed. COD values of raw wastewaters samples 1, 2, 3, 4 and 5 were as follows: 7293, 3241, 3241, 5132 and 1089 mg/l, respectively. Before coagulation easily settleable suspended solids were removed by 30 min primary sedimentation. After sedimentation COD values were decreased to 1134, 2512, 3241, 1858 and 1089 mg/l, respectively. Coagulation with Al2 (SO4)3 at pH 7.0 and FeCl3 at pH 6.0 and 9.0 allowed to achieve COD removal in the range of 33.0–63.5%. The effect of coagulation was better for the samples of lower contents of easily settleable suspended solids and higher content of fine suspended solids. The best effects of COD removal by coagulation achieved for investigated wastewaters were as follow: sample 1 – 39.2%, by Al2 (SO4) 3 and FeCl3 at pH 9.0; sample 2 – 54.8%, by FeCl3 at pH 6.0; sample 3 – 60.0%, by Al2 (SO4) 3; sample 4 – 33.3%, by Al2 (SO4) 3; sample 5 – 63.5%, by FeCl3 at pH 6.0. The differences in coagulants effectiveness were not significant. Flopam flocculant improved the effect of coagulation – shortened the clarification time from 60 min to 5 min, reduced the coagulant doses by about 50 mg/l and increased COD removal. In the coagulation assisted by Flopam flocculant, Al2 (SO4) 3 proved to be the best coagulant for sample 3 (62.5%), FeCl3 at pH 6.0 was the best for sample 2 (54.8%) and sample 5 (63.9% – the best result of all) and FeCl3 at pH 9.0 for sample 4 (50.0%). The best effect of coagulation was achieved for sample no 5, which had no easily settleable suspended solids. The total effect of COD removal, including primary sedimentation and coagulation ranged from 63.9 to 90.6%. GC-MS analysis allowed to identify 110 compounds. The predominant compounds identified by GC-MS were: cyclopentasiloxane, decamethylcyclopentasiloxane and synthetic musk – galaxolide (HHCB). HHCB concentration was decreased in the coagulation by 87.3–92.2%. The degree of other compounds removal varied in the range 0–99.4%.
PL
Podano wyniki pomiarów ugięć belek żelbetowych pod obciążeniem krótkotrwałym. Stwierdzono, że metoda obliczania doraźnych ugięć elementów żelbetowych od obciążeń krótkotrwałych, zarówno według PN-B-03264:2002, jak i PN-EN 1992-1-1:2008, daje wyniki znacznie różniące się od rezultatów badań. Praktycznie od momentu zarysowania obserwuje się „płynięcie” belki przy stałym obciążeniu.
EN
The paper presents results of reinforced concrete beams deflections under short-term load. The calculation results based on PN-B-03264:2002 or PN-EN-1992-1-1:2008 methodology of the reinforced concrete beams under short-term loads, running away from experimental considerably gives results. „Flowing” of concrete beam was practically observed from the moment a first crack appeared.
PL
Przedstawiono nową trójparametrową funkcję rozkładu gęstości prawdopodobieństwa. Przeprowadzone testy zgodności przykładowych doświadczalnych wytrzymałości betonu oraz uzyskanych z obliczeń symulacyjnych łącznych rozkładów funkcji wielu zmiennych losowych wykazały, że funkcja ta dokładniej aproksymuje te rozkłady niż inne znane funkcje rozkładu.
EN
A new type of three parameter probability density function (called NG) with coefficient of skewnees in the interval from O (normal distribution N) to 1,1395 (Gumbel distribution G) has been presented. The enclosed examples of conformity tests have proved better accuracy of this function for approximation of empirical distributions (histograms) than in case of other often used density functions, as well as its usefulness for statistical interpretation of test results.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.