Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The structure of the low-voltage distribution network often changes. The change of topology will affect fault detection, fault location, line loss calculation, etc. It leads to fault detection error, inaccurate positioning and abnormal line loss calculation. This paper presents a new method to automatically identify the topology of a low-voltage power grid by using the injection current signal. When the disturbance current signal is injected into the low-voltage line, the current upstream of the injection point will change, and the current downstream of the injection point will not be affected. It is proved theoretically by using the superposition principle. With this method, the disturbance current signal can be injected into the line in turn, and the topology can be identified by observing the change of the current in line. The correctness of the method is proved by Matlab simulation and laboratory verification.
EN
The topology of low-voltage distribution systems changes with the load or the on/off position of the circuit switch. This will affect power flows, losses, and so on. This paper submits a new method to identify the topology of a low-voltage feeder using the injection high-frequency signal. An inductor can block the high-frequency signal. It can change the propagation direction of the injected high-frequency signal to make it propagate unidirectionally along the low-voltage feeder. By injecting a 5 MHz sinusoidal signal from the upstream direction of the low-voltage feeder, all the line segments and devices on the feeder can be identified. The wavelength of the high-frequency signal is short. The wavelength of the 5 MHz signal is 60 meters. Through the delay of different observation points on the feeder, the length of the line section can be roughly calculated. The high- frequency signal has an obvious reflection on the feeder. Using this feature, we can roughly calculate the length of the line segment. The correctness of the method is demonstrated by MATLAB simulation verification.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.