Zaprezentowano nową ideę odzysku materiałów z odpadowych kompozytów złożonych z niemetali i metali oraz posiadających strukturę warstwową. Ideę tą zobrazowano na przykładzie recyklingu płytek obwodów drukowanych. Porównano metodę opartą na nowej idei recyklingu z metodą tradycyjną opartą na technologii mielenia i strzępienia. Pokazano, że nowa metoda może być mniej energochłonna i bardziej selektywna od obecnie stosowanej.
EN
It was presented a new idea of materials recovery from waste composites composed of non-metals and metals and having a layered structure. The idea was illustrated on the example of recycling process of printed circuit boards. The new method of recycling was compared with the traditional method based on the grinding and shredding technology. It was showed that the new method can be more energy efficient and more selective than the used nowadays ones.
Artykuł dotyczy zarządzania ochroną środowiska w przedsiębiorstwie produkującym obwody drukowane. Opisuje podstawowe problemy o.ś. występujące w branży i wskazówki do zorganizowanego sposobu ich rozwiązywania przy użyciu metody Czystszej Produkcji. W artykule opisano przykłady wytypowanych tą metodą i zrealizowanych projektów ograniczania emisji odorów i tlenku węgla do atmosfery, niklu do ścieków, ograniczania ilości osadów pozostałych po neutralizacji ścieków.
EN
The article refers to issues of environmental management at the plant manufacturing PCBs. It discusses the basie issues of environmental protection and related to the sector, as well as instructions for organised way of solving such issues by adopting Cleaner Production method. In the article examples arę described of emission reduction projects selected and implemented by adopting that method, with regard to emissions of odours and carbon oxide to atmosphere, nickel to sewage, and reduction of post-neutralization sewage sediments.
Celem prezentowanej pracy było skonstruowanie membranowych elektrod jonoselektywnych do oznaczania ketoprofenu. Zastosowano czujniki z ciekłym kontaktem ISE (typ IS 561, Philips) oraz czujniki ze stałym kontaktem typu BMSA (Zakład Chemii Analitycznej i Analizy Instrumentalnej UMCS) zawierające hydrofobowe pary jonowe w mikroporowatej (z polichlorku winylu) warstwie matrycowej. Wyznaczono podstawowe parametry analityczne czujników tj. zakres pomiarowy, nachylenie charakterystyki, granicę wykrywalności, współczynniki selektywności, czas odpowiedzi, zależność SEM od pH, czas życia.
EN
The aim of the presented work was to create membrane ion-selective electrodes for ketoprofen determination. There were used sensors with liquid contact so called conventional ion-selective electrode ISE (type IS 561, Philips) and sensors with solid contact so called BMSA (Institute of Analytical Chemistry and Instrumental Analysis UMCS) containing hydrophobic ion pairs in the microporous (PVC) matrix layer. The latter electrode does not have any inner solution and it posses all the advantages of the "coated wire electrodes" (CWE). The following basic electrode parameters were investigated: measurement range, slope of characteristic, limit of detection, response time, dependence of the electrode potential on pH, lifetime and selectivity coefficients in relation to some organic and inorganic anions. The ketoprofen electrode was used for ketoprofen determination in the synthetic sample and pharmaceutical Ketonal (Lek Pharmaceuticals d.d. Slovenia) within the concentration range of 25.43 - 25430 žg/ml in water solution at pH 5.0 - 9.5. The statistical parameters (Recovery 100,6%, RSD =5,5%) show the typical accuracy of the analytical methods employing ion - selective electrodes.
Autor relacjonuje i komentuje przebieg dyskusji nad ograniczeniem nieformalnego zbierania i przetwarzania zużytego sprzętu elektrycznego i elektronicznego.
EN
The author reports and comments a discussion on limitations of informal collecting and recycling of waste electrical and electronic equipment.
Autor przedstawia w referacie genezę i treść zasad zrównoważonego rozwoju w odniesieniu do środowiska i praktyczną metodę ich realizacji przez wdrażanie systemów zarządzania środowiskiem w przedsiębiorstwie. Zawiera odniesienia do sformalizowanych i niesformalizowanych systemów zarządzania środowiskiem opartych na strategii Czystszej Produkcji, ISO 14001 i EMAS. Referat podaje przykłady działań organizacyjnych, możliwych do stosowania w małych i średnich zakładach produkujących podzespoły i sprzęt elektroniczny.
EN
In the paper, the Author discusses the origin and content of sustainable development principles in reference to the environment and the practical method of implementing of environmental management systems in an organization. He refers to formalized and non-formalized environmental management systems based on the Cleaner Production strategy, ISO 14001and EMAS. The paper gives examples of organizational activities, possible to achieve in small and medium size production organizations manufacturing sub-assembly products and electronic equipment.
The effects of the addition of ionic liquids (ILs) to the membrane phase on the potentiometric properties of strontium-selective electrodes were investigated. The studies were carried out with plasticized PVC membranes doped with bis[(trifluoromethyl)sulfonyl] amides. The electrode basic analytical parameters, such as detection limit, linear range, slope characteristics, response time and dependence of the electrode potential on pH as well as selectivity coefficients in relation to some inorganic cations were determined. As follows from the studies the addition of ILs to the membrane phase improved the analytical parameters of the studied electrodes, especially the improvement in selectivity was notable.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Membrane electrodes sensitive to various drugs have found many applications in pharmaceutical analysis. The sensors offer the advantages of simple design, construction and manipulation, reasonable selectivity, fast response time. With previous preconcentration of the sample, the detection limits of potentiometric techniques using membrane sensors, may equal or surpass those of some expensive and sophisticated techniques such as spectrophotometry, gas-liquid chromatography, high-performance chromatography. In this review the ion-selective electrodes for drugs, containing ion-pair complexes and comprising a plasticized poly(vinyl) chloride membrane are described. The material used in this review was obtained from the major analytical, electroanalytical and pharmaceutical journals. The article is intended to whose who deal with ion-selective electrodes in organic and pharmaceutical analysis.
Od skonstruowania przez Habera i Klemensiewicza [1] pierwszej elektrody jonoselektywnej ze szklaną membraną, która selektywnie reaguje na jony wodorowe upłynie niebawem sto lat. Od tego czasu zbudowano wiele membranowych elektrod, które są obecnie szeroko stosowane do oznaczania zarówno prostych jonów, jak i skomplikowanych związków chemicznych.
9
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
An optimal composition of a liquid, chelating and potential-creating phase of the zinc function electrode was established. Its basic analytical parameters, such as the slope, the detection limit, life time, response time, selectivity for the nickel, cobalt, calcium, cadmium, mercury, copper and sodium ions, as well as the dependence of the electrode potential on pH were established. The electrode was used to determine the content of the zinc ions in the vitamin preparations.
PL
Opracowano optymalny skład fazy potencjalotwórczej, jonoselektywnej elektrody o funkcji cynkowej oraz wyznaczono jej podstawowe parametry analityczne: nachylenie charakterystyki, limit detekcji, czas życia, czas odpowiedzi, selekiywność względem jonów niklu, kobaltu, wapnia, kadmu, rtęci, miedzi i sodu, a także zależność potencjału elektrody od pH. Elektrodę zastosowano do oznaczania zawartości jonów cynku w preparatach witaminowych.
10
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The ion-selective electrode with a pseudoliquid membrane phase of ibuprofen function was prepared. Its basic analytical parameters like: characteristics slope, measuring range, detection limit, response time, life time, and selectivity coefficients towards some organic and inorganic anions were determined. The electrode was applied for the determination of ibuprofen in this aqueous solutions.
PL
Opracowano elektrodę jonoselektywną z pseudociekłą fazą membranową o funkcji ibuprofenowej. Wyznaczono jej podstawowe parametry analityczne takie jak: nachylenie charakterystyki, zakres pomiarowy, limit detekcji, czas odpowiedzi, czas życia i współczynniki selektywności w stosunku do niektórych anionów organicznych i nieorganicznych. Elektrodę zastosowano do oznaczeń ibuprofenu w roztworach wodnych.
Comparison of effects of ozonization and sound amplification. Installation scheme for testing of neutralization and pollution by means of ozone and últrasounds.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W pracy przedstawiono wyniki badań natury, właściwości powierzchniowych oraz podatności na redukcję binarnych układów tlenkowych CeO2-TiO2 oraz naniesionych na nie katalizatorów platynowych przy zastosowaniu różnorodnych metod badawczych (TPR, TPO, BET, XRD, XPS, chemisorpcja wodoru, testy aktywności katalitycznej).
EN
This work presents the results of studies on the nature, surface properties and susceptibility to the reduction of binary oxide systems CeO2-TiO2 and supported on them platinum catalysts using different research methods (TPR, TPO, BET, XRD, XPS, hydrogen chemisorption, catalytic activity tests).
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.