EN
The objective of the present study is to assess the efficiency of fly ash and fly ash agglomerates to remove arsenic(III) from aqueous solution. The maximum static uptakes were achieved to be 13.5 and 5.7 mgAs(III)/adsorbent for nonagglomerated material and agglomerated one, respectively. Isotherm studies showed good fit with the Langmuir (fly ash) and the Freundlich (fly ash agglomerates) isotherm models. Kinetic studies indicated that the sorption of arsenic on fly ash and its agglomerates follows the pseudo-second-order (PSO) chemisorption model (R2 = 0.999). Thermodynamic parameters revealed an endothermic nature of As(III) adsorption on such adsorbents. The adsorption results confirmed that fly ash and its agglomerates can be used for As(III) removal from aqueous solutions. Fly ash can adsorb more arsenic(III) than agglomerates, which are easier to use, because this material is less dusty and easier to separate from solution.
PL
Celem pracy było przetestowanie przydatności zbudowanego w Zakładzie Inżynierii Chemicznej Politechniki Wrocławskiej niskobudżetowego układu pomiarowego PIV do pomiaru burzliwych pól prędkości w laboratoryjnym mieszalniku strumieniowym. Wyznaczone w czasie badań profile prędkości płynu w wypływającej strudze w różnych odległościach od wylotu dyszy, dla różnych natężeń przepływu porównano wartościami obliczonymi z zależności literaturowych. Na tej podstawie określono metodę uśredniania pola prędkości.
EN
The goal of this work was to test the usability of low-costing PIV measuring system built in the Department of Chemical Engineering of Wroclaw University of Technology and used to measure turbulent liquid veIocity field in a jet mixer. The profiles of liquid velocity at different distances from a nozzle outlet were compared with the values calculated from literature equations. On this basis, the optimal method of liquid velocity field avera-ging was determined.
3
Content available Modelowanie CFD wypływu kropli z dystrybutora
PL
W pracy przedstawiono symulację CFD powstawania kropli w pojedyn-czym dystrybutorze w kolumnie ekstrakcyjnej. Określono wpływ takich parametrów, jak średnica dystrybutora, temperatura oraz prędkość fazy w dystrybutorze na wielkość kropli, co pozwala na zaprojektowanie dystrybutora o optymalnym rozmiarze. Wyniki symulacji CFD mogą dać cenne informacje dotyczące tworzenia się kropli. Uzyskane wyniki symulacji zweryfikowano poprzez porównanie z wartościami obliczonymi z korelacji literaturowych.
EN
CFD simulation was used to investigate drop formation in a single hole of the distributor working in a solvent extraction column. Effect of various operating and design parameters on drop formation was investigated in order to optimize a distributor construction. Results indicated that CFD simulations could provide useful information on drop formation. Simulation results were verified by comparison to well-known correlation data.
4
Content available Modelowanie CFD mieszalnika strumienicowego
PL
Celem pracy było opracowanie modelu matematycznego opisującego mieszalnik strumienicowy oraz jego weryfikacja na podstawie przeprowadzonych wcześniej badań eksperymentalnych. Model umożliwia wyznaczenie najważniejszych parametrów hydrodynamicznych, tj. współczynnika ejekcji strumienicy, a także pól prędkości oraz ciśnienia wewnątrz aparatu. Pozwala zatem na badanie wpływu zmiennych konstrukcyjnych i ruchowych na proces mieszania. Model posłuży w przyszłości do optymalizacji działania mieszalnika strumienicowego.
EN
The aim of this work was to develop and verify a CFD model describing the jet pump mixer. The model verification was carried out on basis of our earlier experimental investigations. This model enables the calculation of velocity and pressure fields inside the apparatus. Therefore, one can examine the influence of hydrodynamic and constructional variables on mixing process. In the future this model should be used for the optimization of jet pump mixer for crude oil desalination.
PL
Wykonano eksperymentalne badania procesu usuwania Cu(II) z roztworów wodnych przy użyciu ceramicznej membrany wypełnionej roztworem eteru koronowego 4,13-diaza-18-korona-6 w bis(trifluorometylosulfonylo)imid- ku l-decylo-3-metylo imidazoliowym [C10MIM][NTf2]. Określono wpływ gradientu temperatur i pH fazy akceptorowej na szybkość transportu Cu2+ przez membranę. Stwierdzono, że dodanie fosforanu tributylu do [C|0MIM] [NTf2] (1:1 v/v) nieznacznie obniża współczynnik podziału Cu(II) w badanym układzie.
EN
Experimental studies on removal of copper(II) from aqueous solutions using a ceramic membrane contactor with 4,13-diaza-18-crown-6 ether as carrier dissolved in l-decyl-3-methylimidazolium bis(trifluoromethylsul- fonyl)amide [C10MIM][NTf2] were carried out. The influence of temperature gradient and external phase pH on mass-transfer rate of Cu2+ was experimentally investigated. It was found that the addition of 50% (v/v) of tributyl phosphate (TBP to [C10MIM][NTf2].
6
Content available remote Sorption properties of fly ash from brown coal burning towards arsenic removal
EN
In the present work, the sorptive capacity of fly ash from the combustion of brown coal in relation to arsenic(III) removal from the standard solution as well as the potential application of fly ash in actual wastewater purification have been evaluated.
PL
W tym artykule zbadano pojemność sorpcyjną popiołów lotnych powstających podczas spalania węgla brunatnego w stosunku do arsenu(III) usuwanego z roztworu standardowego oraz zbadano możliwość zastosowania popiołów w oczyszczaniu ścieku rzeczywistego.
8
PL
Celem niniejszej pracy było zbadanie zdolności sorpcyjnych popiołu po spalaniu węgla brunatnego pod kątem adsorpcji arsenu (III). Uzyskane wyniki wskazują na znaczną pojemność sorpcyjną popiołu lotnego względem As(III) (33 mg/g), porównywalną do otrzymywanej na żywicach jonowymiennych. Dane doświadczalne dobrze opisuje izoterma Langmuira, a proces adsorpcji kontrolowany jest reakcją chemiczną pseudo drugiego rzędu (model PSO).
EN
The aim of work was to examine sorption of As(III) species, using fly ash from lignite burning. The results obtained show that the sorption capacity of fly ash (33 mg/g) is comparable to commercial sorbent. Experimental data can be described by means ofLangmuir isotherm. Adsorption process obeys the pseudo-second order (PSO) kinetics.
PL
Ciecze jonowe posiadają potencjalne zastosowanie w technikach separacyjnych. W niniejszej pracy badano zdolność heksafluorofosforanu 1-butylo-3-metyloimidazoliowego [BMIM][PF6] do rozdziału wodnych mieszanin metanolu, etanolu i propanolu. Eksperymentalnie uzyskano dane dla równowag ciecz-ciecz dla układów [BM1M][PF6] - alkohol - woda w temperaturze 298,15 K. Dane doświadczalne zostały w satysfakcjonujący sposób skorelowane za pomocą modelu NRTL.
EN
Ionic liquids have potential usability in separation techniques. In this work, ability of l-buthyl-3-methylimidazolium hexafluorophosphate [BMIM] [PFJ to separate methanol, ethanol and propanol from water was investigated. Liquid - liquid equilibrium data for [BMIM][PF6] - alcohol - water systems were measured at 298.15 K. The phase equilibrium data were satisfactorily correlated using the non-random two-liquid (NRTL) model.
10
PL
W pracy przedstawiono wyniki optymalizacji pompy strumieniowej. W procesie optymalizacji wykorzystano popularne ostatnio metody CFD (numerycznej mechaniki płynów). Opracowany model CFD umożliwił obliczenie rozkładów prędkości oraz ciśnienia wewnątrz aparatu. Wyznaczono także współczynnik ejekcji, który porównano z danymi eksperymentalnymi. Błąd średni obliczeń dla 36 punktów pomiarowych wyniósł -10%. Za pomocą modelu CFD przetestowano wpływ zmiennych konstrukcyjnych i ruchowych na wartość współczynnika ejekcji. Wykazano, że strumienica posiada zbyt długą komorę mieszania, która powoduje nadmierne straty ciśnienia.
EN
Results of the jet pump optimization were presented in the paper. CFD (Computational Fluid Dynamics) methods were used during optimization. The developed mathematical model enabled one to calculate the liquid velocity and pressure profiles inside the apparatus. The efficiency coefficient values obtained from the model differed from experimental results with the average error of-10%. The axial static pressure profile showed that the mixing chamber was too long and it should be shortened.
EN
Extraction of several chloro compounds from water has been examined. As the extracting liquid the 1-butyl-3-methylimidazolium hexafluorophosphate [BMIM][PF6], which is common hydrophobic ionic liquid, was used. Additionally, extraction of selected chlorinated compounds from tert-butylmethylether (MTBE) was investigated. The obtained results show the usefulness of [BMIM][PF6] to remove the organic impurities from water, particularly at the concentration range inappropriate for biological purification plants.
12
Content available remote Oil agglomeration of mineral tailings in mixed-surfactant systems
EN
In this paper the results of spherical oil agglomeration of mineral tailings were presented. Tailings from nickel recovery (the Szklary heap, Lower Silesia, Poland) were used in these investigations. Agglomeration experiments have been carried out in water suspension of mineral particles in the presence of cationic and anionic surfactants and kerosene as bridging oil.
PL
W niniejszym artykule przedstawiono wyniki badań procesu aglomeracji olejowej odpadów mineralnych, pozostałych po hutniczej obróbce rudy niklowej, zgromadzonych na hałdzie w okolicach miejscowości Szklary na Dolnym Śląsku. Proces prowadzono w zawiesinie wodnej cząstek mineralnych w obecności surfaktantu kationowego oraz anionowego, użytych jako substancje modyfikujące właściwości powierzchniowe ciała stałego oraz emulgatora oleju (nafty) w wodzie.
EN
The scope of this contribution was to investigate in detail an application of fly ash adsorbent for the removal of arsenite ions from a dilute solution. The experiments have been carried out using fly ash from black coal burning power plant "Siersza" and brown coal burning power plant "Turów" (Poland), which was wetted, then mixed and tumbled in the granulator with a small amount of cement to increase the mechanical strength of agglomerates. The measurements of arsenic adsorption from the aqueous solution were carried out in the flask (with shaking), as well as in the column (with circulation), in order to compare two different methods of contacting waste with adsorbent. The adsorption isotherms of arsenic were determined for granulated material, using the Freundlich model. Kinetics studies indicated that the sorption follows a pseudo-first-order (PFO) model (Lagergren) and the Elovich-type model.
PL
W pracy przedstawiono wyniki badań eksperymentalnych ruchu ciepła i masy podczas cienkowarstewkowego odparowania roztworów: woda-glikol propylenowy, woda - gliceryna w wyparce z rozcieranym filmem. Zastosowane ciecze posiadają lepkości w granicach 4-9 mPa?s w warunkach przeprowadzonych badań, a ich składniki różnią się znacząco lotnością. Wyznaczono wartości współczynników przenikania ciepła. Stwierdzono istnienie oporu dla ruchu masy po stronie fazy ciekłej podczas procesu odparowania. Wyznaczono wartości współczynników wnikania masy w cieczy.
EN
The results of experimental investigation on heat and mass transfer during evaporation of water - propylene glycol and water - glycerin solutions in a thin-layer evaporator are presented in the paper. Liquids used in experiments possessed viscosity in the range from 4 to 9 mPa-s and constituents of these liquids differ significantly taking into account their volatility. Overall heat transfer coefficients were determined. Mass transfer resistance in the liquid phase was confirmed during distillation process. Mass transfer coefficients were also determined.
PL
W pracy przedstawiono model CFD hydrodynamiki strumienicy jednocieczowej, który został następnie zweryfikowany doświadczalnie. Przeprowadzone badania stanowiły pierwszy etap opracowania nowej metody odsalania surowej ropy naftowej z użyciem strumienicy. Zaproponowany model, zastosowano do obliczeń ciśnienia na wlocie do komory mieszania. Średni błąd obliczeń modelowych w stosunku do danych doświadczalnych wyniósł 30%, przy czym model w sposób poprawny jakościowo przewidywał działanie strumienicy oraz profile prędkość i ciśnienia wewnątrz aparatu.
EN
CFD modeling of hydrodynamics of a jet pump is presented in the paper. The results of model calculations are compared with the experimental ones. The work established a first stage in elaboration of a novel method for crude oil desalination. In this method the jet pump operates as a mixer for a two-phase liquid system. Mathematical model calculations of pressure at the inlet of mixing chamber differ from experimental results with an average error of 30%. A performance of the jet pump, as well as velocity and pressure profiles inside the device are described fairly well by the mathematical model.
PL
W pracy przedstawiono wyniki badań eksperymentalnych hydrodynamiki i wymiany masy w ekstrakcyjnym układzie octan n-bu-tylu + kwas octowy woda. Badania wykonano w kolumnie z posuwisto- zwretnym ruchem półek sitowych dla kierunku wymiany masy z fazy rozproszonej do fazy ciągłej. Wyróżniono nowy obszar pracy RFC - emulsyjno-agregatowy.
EN
The system of ri-butyl acetate + acetic acid —ť water (with mass transfer from dispersed to continuous phase) in a reciprocating plate column (RFC) was investigated. The experiments with high flow of both phases covered a full useful range of Apf. A new operating range of the RFC called the emulsion-aggregate regime was found.
PL
Niskotemperaturowe ciecze jonowe są nowymi, przyjaznymi środowisku rozpuszczalnikami, które mogą zostać zastosowane w przemyśle chemicznym. Przedstawiono potencjalne możliwości zastosowania tych interesujących substancji.
EN
Room temperature ionic liquids are novel, enviromentally friendly solvents, which can be used in chemical industry. This paper presents a review of the potential applications of these unique liquid materials.
PL
W pracy zweryfikowano własny kinetyczny model populacji kropel w ekstraktorze przez porównanie obliczonych i doświadczalnych rozkładów wielkości kropel w kolumnie rozpyłowej, wypełnionej i z wibrującymi półkami (RPC). Stwierdzono dobrą zgodność obliczonych i zmierzonych rozkładów oraz wielkości kropel.
EN
Experimental data obtained for three distinctive kinds of columns (spray, packed, and reciprocating plate columns - RPC) were used to verify a kinetic model of drop population in any type of extractor. A favourable correlation was found between the data predicted by the model and those actually obtained through experimental observation.
PL
Zaproponowano kinetyczny model populacji kropel w kolumnie ekstrakcyjnej dowolnego typu. Układ równań szybkości koalescencji i redyspersji rozwiązywano dla warunków stacjonarnych. Przedstawiono sposób podziału na klasy i różne rodzaje rozkładów wielkości kropel. Sporządzono histogramy tych rozkładów.
EN
A kinetic model of drop population in any type of extraction column was proposed. The system of equations for the rate of coalescence and redispersion in steady-state conditions was solved. The way of division into classes and different distribution types were presented.