The power output of plasma experiments and fusion reactors is a crucial parameter. It is determined by neutron yields that are proportional and directly related to the fusion yield. The number of emitted neutrons should be known for safety reasons and for neutron budget management. The PF-1000 is the large plasma facility based on the plasma focus phenomenon. PF-1000 is operating in the Institute of Plasma Physics and Laser Microfusion in Warsaw. Neutron yield changes during subsequent pulses, which is immanent part of this type device and so it must be monitored in terms of neutron emission. The reference diagnostic intended for this purpose is the silver activation counter (SAC) used for many years. Our previous studies demonstrated the applicability of radio-yttrium for neutron yield measurements during the deuterium campaign on the PF-1000 facility. The obtained results were compared with data from silver activation counter and shown linear dependence but with some protuberances in local scale. Correlation between results for both neutron monitors was maintained. But the yttrium monitor registered the fast energy neutron that reached measurement apparatus directly from the plasma pinch. Based on the preliminary experiences, the yttrium monitor was designed to automatically register neutron-induced yttrium activity. The MCNP geometrical model of PF-1000 and yttrium monitor were both used for calculation of the activation coefficient for yttrium. The yttrium monitor has been established as the permanent diagnostic for monitoring fusion reactions in the PF-1000 device.
EN
The neutron emission rate is a crucial parameter for most of the radiation sources that emit neutrons. In the case of large fusion devices the determination of this parameter is necessary for a proper assessment of the power release and the prediction for the neutron budget. The 14 MeV neutron generator will be used for calibration of neutron diagnostics at JET and ITER facilities. The stability of the neutron generator working parameters like emission and angular homogeneity affects the accuracy of calibration other neutron diagnostics. The aim of our experiment was to confi rm the usefulness of yttrium activation method for monitoring of the neutron generator SODERN Model: GENIE 16. The reaction rate induced by neutrons inside the yttrium sample was indirectly measured by activation of the yttrium sample, and then by means of the γ-spectrometry method. The pre-calibrated HPGe detector was used to determine the yttrium radioactivity. The emissivity of neutron generator calculated on the basis of the measured radioactivity was compared with the value resulting from its electrical settings, and both of these values were found to be consistent. This allowed for a positive verifi cation of the reaction cross section that was used to determine the reaction rate (6.45 × 10–21 reactions per second) and the neutron emission rate (1.04 × 108 n·s–1). Our study confi rms usefulness of the yttrium activation method for monitoring of the neutron generator.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.