Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper describes a tester for automated testing of power quality analyzers, focuses on evaluation of correct gapless and non-overlapping measurement according to standard IEC 62586-2[1]. A test is used in order to verify the accuracy of the basic time window for evaluating RMS voltage values (10/12 cycle), and to evaluate whether during the measurements RMS samples (gapless) are not lost and mutual overlaps of individual cycles are not produced. The tester is based on principles of virtual instrumentation. The testing hardware uses PXI system architecture and the software is made in NI LabVIEW programming environment.
EN
The new edition of IEC 61000-4-15 has brought some changes in the implementation and testing requirements of flicker meters as a part of power quality analyzers. This article describes the software which was made to test the flicker parameter at the power quality analyzers according to updated IEC 61000-4-15.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.