Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Three different alkaline filtration materials were selected for orthophosphates(V) removal from biologically treated domestic sewage. As early as 35 weeks after starting filter operation one of the materials with typical granular limestone characteristics (calcium content of about 50%) was excluded from the test due to high bed clogging that inhibited its further exploitation. Tests of the two other materials with substantially lower calcium content continued uninterrupted throughout the 96-week research period. An average efficacy of phosphates removal for both materials was 80–90% at filtration rate of 0.6 m/d and 50–55% – at the rate of 1.2 m/d. Phosphates removal from sewage with the alkaline filter beds resulted from chemical precipitation of apatite deposits on the surface of filter material grains. However, such filtration materials could be applied to removal of phosphates (e.g. in household sewage treatment systems) provided that the sewage pH in the filter effluent did not exceed 8.5.
PL
Do usuwania ortofosforanów(V) z biologicznie oczyszczonych ścieków bytowych zastosowano trzy materiały filtracyjne o charakterze alkalicznym. Jeden z tych materiałów, o cechach typowego granulatu wapiennego (zawartość wapnia około 50%), został wyłączony z badań już po 35 tygodniach eksploatacji filtru, ponieważ powodował silną kolmatację złoża, uniemożliwiającą jego dalszą eksploatację. Badania dwóch pozostałych materiałów, zawierających mniejszą ilość wapnia (15–20%), prowadzono bez zakłóceń przez 96 tygodni. Średnia skuteczność usuwania fosforanów z użyciem obu tych materiałów przy prędkości filtracji 0,6 m/d wynosiła 80÷90%, natomiast przy prędkości filtracji 1,2 m/d odpowiednio 50÷55%. Usuwanie fosforanów ze ścieków na alkalicznych złożach filtracyjnych było efektem ich chemicznego strącania w postaci apatytów na powierzchni ziaren złóż. Jednakże takie materiały filtracyjne mogą być stosowane do usuwania fosforanów (np. w przydomowych oczyszczalniach ścieków) pod warunkiem, że wartość pH ścieków w odpływie z filtru nie wzrośnie powyżej 8,5.
PL
Przydatność wybranych materiałów do usuwania fosforu ze ścieków bytowych można wstępnie ocenić, badając efektywność jego sorpcji z roztworów kontrolnych. Testowano cztery wybrane materiały mineralne, a ich efektywność w zakresie usuwania fosforu porównywano, wykorzystując do tego równania izoterm adsorpcji Langmuira i Freundlicha. Wyniki testów potwierdziły doniesienia literaturowe, że właściwości sorpcyjne badanych materiałów zależą w sposób istotny od zawartości w nich reaktywnych związków wapnia. Największą maksymalną pojemnością sorpcyjną charakteryzował się materiał nr 3 (285 mg P/g), a znacznie mniejszą materiały nr 2 (159 mg P/g), nr 1 (56 mg P/g) i nr 4 (2,4 mg P/g). Zaprezentowana metoda może być użytecznym narzędziem do szybkiej ilościowej kwalifikacji mineralnych adsorbentów fosforu w roztworze.
EN
Four grinded mineral materials were studied for their ability of P sorption from the aq. phosphate solns. in 24-h tests by using equations of Langmuir and Freundlich isotherms. The particular sorbents contained mainly CaO 21.6% and Al2O3 5.6%, CaO 29.6% and Fe2O3 12.3%, CaO 69.4%, Al2O3 14.0% and CaO 8.4%, and showed the sorption capacities 56, 159, 285 or 2.4 mg/g, resp.
PL
Oceniono technologiczną niezawodność przydomowej hybrydowej oczyszczalni ścieków bytowych, opracowanej w ITP-GCB w Tyliczu, analizując stabilność procesów zmniejszania się w niej wskaźników zanieczyszczeń BZT5 i ChZT oraz stężenia zawiesiny ogólnej (ZO). Analizie poddano kompletną oczyszczalnię (KO) oraz jej element składowy - złoże o przepływie pionowym ścieków (ZPV). Do analizy statystycznej zastosowano metodę Weibulla, zmodyfikowaną przez BUGAJSKIEGO i in. [2012]. Wykazano, że KO działa ze 100-procentową niezawodnością, biorąc pod uwagę zgodność wskaźników: BZT5, ChZT i ZO w oczyszczonych ściekach z wymaganiami zawartymi w rozporządzeniu Ministra Środowiska [2006] dla odprowadzenia ścieków do wód. Niezawodność technologiczna złoża ZPV (BZT5 - 44%, ChZT - 91% i ZO - 76%) jest niewystarczająca, aby można było wykorzystać je jako samodzielną oczyszczalnię.
EN
Paper presented an assessment of technological reliability for a hybrid, domestic wastewater treatment plant, designed at the Mountain Research Center, Tylicz. Stability of reduction processes was analysed with respect to the pollutant parameters (BOD5, COD) and the concentration of total suspended solids (TSS). The tests included complete treatment plant (CTP), and one of its component - vertical flow bed (VFB). The Weibull’s method, modified by BUGAJSKI et al. [2012], was applied to statistical analysis. It was stated that the complete treatment plant worked at 100% reliability, considering the compliance of effluent BOD5, COD and TTS, with the standards given in an ordinance of the Minister of Environment [2006] for sewage discharge into waters. Technological reliability of the VFB (BOD5 - 44%, COD - 91%, TSS - 76%) was insufficient to its use as an independent, separate sewage treatment plant.
PL
Celem 8-letnich badań (2004-2012), prowadzonych w warunkach klimatu górskiego, było porównanie i ocena efektów usuwania azotu ze ścieków bytowych w dwóch konstrukcyjnie podobnych urządzeniach ze zraszanymi złożami z wypełnieniem z granulatów keramzytowych. Analizowano zmiany N-NH4, N-NO3, Ntot w obiektach pracujących w różnych warunkach temperatury, obciążenia hydraulicznego i ładunku substratu organicznego (BZT5). W warunkach większego obciążenia złoża 2. substratem organicznym (średnie BZT5 = 78,60 g O2·m-2·d-1) efektywność nitryfikacji (η = 80%, K20 = 0,543 d-1) była mniejsza niż w mniej obciążonym (średnie BZT5 = 46,35 g O2·m–2·d–1) złożu 1. η = 91%, a K20 do 2,398 d-1. Odwrotnie zaś w warunkach większego obciążenia złoża 2. substratem organicznym efektywność denitryfikacji i szybkość usuwania azotu SUZ były większe (η = 30%, SUZ = 7,86 g·m-2·d-1) niż w złożu 1. mniej obciążonym substratem organicznym (η = 11%, SUZ = 1,55 g·m-2·d-1). Procesy nitryfikacji w złożach można zintensyfikować przez zmniejszenie obciążenia ich powierzchni ładunkiem organicznym, dopasowując konstrukcyjnie zraszane powierzchnie do większego stężenia zanieczyszczeń organicznych w ściekach odpływających z wiejskich osadników gnilnych.
EN
During 8 year’s study (2004-2012), conducted in the mountain climate, the effects of domestic wastewater treatment in two similar construction facilities with trickling filter beds filled with LECA, were compared and evaluated. The changes of BOD5, N-NH4, N-NO3 and Ntot in the beds working under various conditions of temperature, hydraulic load and the load of organic substrate (BOD5), were analysed. Effectiveness of nitrification (η = 80%, K20 = 0.543·day-1) was lower in bed 2, with higher load of organic substrate (average BOD5 = 78.60 g O2·m-2·day-1), than the effectiveness (η = 91% and K20 to 2.398·day–1) gained in bed 1 with lower load (mean BOD5 = 46.35 g O2·m-2·day-1). On the contrary, effectiveness of denitrification and nitrogen removal rate (η = 30%. SUZ = 7.86 g·m-2·day-1) was higher in bed 2, than in bed 1 (η = 11%, SUZ = 1.55 g·m-2·day-1) which was less loaded. Nitrification process in the beds could be intensified by decreasing organic load of their surfaces by means of constructional adaptation of trickling surfaces proportionally to higher concentration of organic pollutants in wastewater out flowing from the rural septic tanks.
EN
Electrochemical impedance spectroscopy was used to study the adsorption of several surface active substances at the surface of non-stoichiometric copper(I) sulfide. Simultaneously the influence of the treatment of the copper sulfide by the solution of those surface active substances on the leaching rate of the sulfide in oxygenated sulfuric acid solution was investigated and correlated with the type of adsorptive bond formed between the sulfide surface and adsorbed molecules. Both chemisorption and surface precipitation may lead to the formation of a strongly bound product that prevents the dissolution of a mineral. Contrary, physical adsorption is too week to protect the surface from the attack of aggressive medium.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.