Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available The gyrotron for DNP-NMR spectroscopy: A review
EN
This paper outlines the principle of the DNP-NMR technique. The gyrotron, as a very promising microwave source for NMR spectroscopy, is evaluated. Four factors: power stability, power tuning, frequency stability, and frequency tuning determine the usability of the gyrotron device. The causes of instabilities, as well as the methods of overcoming limitations and extending usability are explained with reference to the theory, the numerical and experimental results reported by gyrotron groups.
EN
In this paper, we describe the development and design procedure of the new kind of coaxial TEm,1 modes generator based on ring resonator with coupling apertures. The generator enables excitation of subsequent TEm,1 modes in a cylindrical waveguide. The proposed design method allows to obtain high purity TEm,1 modes. The angular mode number can be chosen by replacing the plate with coupling apertures. Structure and parameters of the generator was optimized using CST-Microwave Studio. The mode generator was fabricated and checked on the test bench in an anechoic chamber. The measured field distributions confirm excitation of the desired TEm,1 modes. A good agreement between simulations and measurements is obtained. The presented mode generator, operating in non-rotating TEm,1 modes, is easy to fabricate, and suitable for cold-test experiments of high power components and devices.
3
EN
In this paper, a simple and fast method relied upon for designing a Vlasov launcher with a helical cut is proposed. The method is based on graphic interpretation of analytical relationships that link wave parameters (EM field mode) to the launcher’s geometrical dimensions. Using the ray tracing method, a simplified graphic analysis may be carried out. The results obtained are not significantly different from those of rigorous full-wave analyzes. The family of normalized curves that is created in the process greatly facilitates the stage of optimizing the geometrical parameters of the Vlasov launcher.
4
Content available Optimization of Gyrotron Resonator’s Dimensions
EN
This paper explains the procedure of determining the initial dimensions of a gyrotron resonator. In particular, the paper discusses which geometrical parameters impact the wave properties of the resonator. The solution is implemented using Matlab software and estimations are performed with the use of the SMath Studio spreadsheet.
EN
This survey presents a review of experimental methods relied upon while implementing gyrotron higher mode generation techniques and performing near electromagnetic field measurements in launcher and quasi-optical mode converters. In particular, the paper focuses on low power (cold) testing of gyrotron quasi-optical mode converters outside of the gyrotron, without the presence of high electromagnetic power and electron beams.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.