An example of determining a fixed control frequency for a series inverter for induction heating is dealt with in this paper, which ensures power control with ZVS switching at varying parameters of the resonant circuit. The analysis has been carried out for three fixed-frequency switching strategies: PS, ADC and ACM. Conditions for a proper operation and resulting problems have also been presented.
PL
W artykule przedstawiono przykład wyznaczania stałej częstotliwości sterowania falownika szeregowego do nagrzewania indukcyjnego, która zapewni regulację mocy przy przełączaniu tranzystorów falownika przy zerowym napięciu i przy zmianach parametrów obwodu rezonansowego. Analizę przeprowadzono dla trzech stałoczęstotliwościowych metod sterowania: PS, ADC i ACM. Podano także warunki uzyskania prawidłowej pracy i występujące problemy.
EN
This paper presents results of experimental research of a resonant switched capacitor voltage multiplier (SCVM) in the synchronous topology (SYSCVM). The classical SCVM utilizes diodes in the branches responsible for charging the switched capacitors. In the SYSCVM, additional MOSFET switches are connected in parallel with the diodes. Therefore, an improvement of efficiency is achieved. The paper presents experimental results of operation and efficiency of the SYSCVM. Furthermore, the issues related to the design of the converter with synchronous switches and the problems of the supply of the gate drivers are discussed.
PL
W artykule przedstawiono wyniki badań eksperymentalnych rezonansowego przekształtnika DC-DC o przełączanych kondensatora powielającego napięcie stałe w topologii synchronicznej (SYSCVM – Synchronous Switched Capacitor Voltage Multiplier). W klasycznym rozwiązaniu analizowany przekształtnik o przełączanych kondensatorach wykorzystuje diody w obwodach ładowania przełączanych kondensatorów. W układzie SYSCVM diody połączone są równolegle z tranzystorami MOSFET dla uzyskania większej sprawności układu. Artykuł przedstawia wyniki pomiarów eksperymentalnych układu dotyczących weryfikacji działania układu oraz jego sprawności. Ponadto, problemy związane z praktyczną implementacją koncepcji synchronicznego układu (SYSCVM) zostają również omówione.
EN
This paper presents the results of experimental research of a resonant switched capacitor voltage multiplier in a cost-effective topology (CESCVM) with a limited number of active switches. In the charging mode of the switched capacitors, the converter utilizes only one active switch and a required number of diodes. Therefore, the cost of the converter is decreased as compared with that of a classical SCVM converter, owing to a lower number of switches and gate driver circuits, as well as a smaller PCB area. Moreover, the CESCVM has simpler control circuits and higher reliability. This paper presents the original experimental results of the operation of the CESCVM converter. A concept of the bootstrap supply of gate drivers of the flying switches is also examined.
PL
W artykule przedstawiono sposób wyznaczania wartości stałej częstotliwości sterowania falownika szeregowego do nagrzewania indukcyjnego, która zapewni przełączanie tranzystorów falownika przy zerowym napięciu w zadanym zakresie temperatury przy możliwości regulacji mocy. Oparto się na przykładowym układzie wzbudnik-wsad o znanej zależności parametrów od temperatury. Analizę przeprowadzono dla trzech stałoczęstotliwościowych metod sterowania PS, ADC i ACM.
EN
A way to determine a fixed switching frequency for a series inverter for induction heating is dealt with in this paper that ensures power control with ZVS switching in a given temperature range. The discussion is based on an example of an inductor-charge system with known parameters over the temperature range. The analysis has been carried out for three fixed-frequency switching strategies: PS, ADC and ACM.
PL
Referat stanowi próbę syntetycznego usystematyzowania stanu wiedzy i technologii na temat ogniw Peltiera oraz obszarów ich zastosowania. To ważny temat, zwłaszcza w czasie, kiedy fotowoltaika zmierza w kierunku nieuchronnej technologii cienkowarstwowej, a świat poszukuje wysoko-sprawnych metod zapewnienia komfortu cieplnego i generacji energii elektrycznej ze źródeł odnawialnych oraz wykorzystania źródeł ciepła odpadowego. Na przykładzie wykonanego modelu modułu klimatyzacyjnego przedstawiono wyniki wykonanych pomiarów i sposób oszacowania jego sprawności. Podane zostały ograniczenia tej technologii i wytyczne konstrukcyjne przy wykorzystaniu ogniw Peltiera w celu optymalizacji ich efektywności.
EN
This paper is an attempt to synthesize the state of knowledge and technology on Peltier modules and areas of their application. It is important, especially at a time when the photovoltaics is heading towards inevitable thin-film technology, and the world is looking for high-efficiency methods to ensure the thermal comfort and generation of electricity from renewable sources and the use of waste heat. Based on the example of a self-made model of an air conditioning module, the authors performed and present the results of measurements and methods of estimating its efficiency. They demonstrate some limitations of technology and give the construction guidelines for implementation of the Peltier cells at optimal efficiency.
EN
The object of the article is a single-switch transistor inverter for induction heating operating optimally in class E. Results of measurements carried out in a novel inverter model at a few values of resonant capacitance for a few types of charge are presented. They are in a good accordance with the conclusions resulting from the theoretical analysis of the inverter.
PL
Przedmiotem artykułu jest jednołącznikowy falownik tranzystorowy do nagrzewania indukcyjnego pracujący optymalnie w klasie E. W artykule przedstawiono wyniki pomiarów zrealizowanych przy kilku wartościach pojemności rezonansowej dla kilku rodzajów wsadu w wykonanym oryginalnym modelu falownika. Potwierdzają one wnioski wynikające z analizy teoretycznej falownika.
EN
This paper presents the concept of topologies and investigation results of switched-capacitor voltage multipliers designed for application in high power systems. The analyzed family of multilevel converters includes established topologies as well as novel concepts. The application of thyristors as well as the invention of novel concepts of multiplier topologies and appropriate control make it possible to achieve high efficiency, high voltage gain, reliable and simple DC-DC converters for high power systems. Based on analytical models of the SCVMs, the paper presents a discussion of the selection of components and the efficiency of the converters as a function of converted power as well as the voltage range on the input and the output side. The results are supported by computer simulations and demonstrative experimental tests.
EN
Three fixed-frequency control strategies for a series resonant inverter for induction heating: PS-PWM, ADC and ACM have been compared in the paper. The analysis has been carried out using decomposition of the inverter output voltage to harmonic components. Special attention has been paid to the determination of conditions assuring ZVS operation of the semiconductor devices and to the inverter efficiency.
PL
W artykule porównano właściwości trzech stałoczęstliwościowych metod sterowania rezonansowego falownika szeregowego do nagrzewania indukcyjnego: ADC, PS-PWM i ACM. Analizę przeprowadzono z wykorzystaniem rozkładu napięcia wyjściowego falownika na składowe harmoniczne. Szczególną uwagę zwrócono na określenie warunków zapewniających przełączanie zaworów przy zerowym napięciu (ZVS) oraz sprawność falownika.
EN
The paper is an attempt of discussion and presentation of the concept of a method for determining efficiency of high frequency inverter systems used in electroheat processes. Based on the example of a constructed model of a single – switch Class E ZVS-1S quasi-resonant inverter and the obtained results of its measurements, an effort of assessment of the inverter performance and its efficiency has been made. The paper presents a brief analysis of the operation and basic relationships in the inverter, the concept of control, conceptual design, difficulties during its implementation and it also identifies sources of power losses in the inverter and determines its efficiency for various load parameters.
PL
Artykuł jest próbą dyskusji i przedstawieniem koncepcji metody wyznaczania sprawności układów falowników wysokoczęstotliwosciowych wykorzystywanych w grzejnictwie elektrycznym. Na przykładzie wykonanego modelu układu jednołącznikowego falownika napięciowego ZVS–1S klasy E i wyników zrealizowanych pomiarów podjęto próbę oszacowania jego sprawności. W referacie przedstawiono pokrótce analizę pracy oraz podstawowe zależności występujące w falowniku, koncepcję jego sterowania, założenia projektowe, trudności wykonawcze oraz określono źródła strat mocy w falowniku i wyznaczono jego sprawność dla różnych parametrów obciążenia.
PL
Artykuł jest próbą dyskusji i przedstawieniem koncepcji metody wyznaczania sprawności układów falowników wysokoczęstotliwosciowych wykorzystywanych w grzejnictwie elektrycznym. Na przykładzie wykonanego modelu układu jednołącznikowego falownika napięciowego ZVS–1S klasy E i wyników zrealizowanych pomiarów podjęto próbę oszacowania jego sprawności. Przedstawiono pokrótce analizę pracy oraz podstawowe zależności występujące w falowniku, koncepcję jego sterowania, założenia projektowe, trudności wykonawcze oraz określono źródła strat mocy w falowniku i wyznaczono jego sprawność dla różnych parametrów obciążenia.
EN
The paper is an attempt of discussion and presentation of the concept of a method for determining efficiency of the high frequency inverter systems used in electroheat processes. Based on the example of constructed model of a single – switch Class E ZVS-1S resonant inverter and obtained results of the measurements, an effort has been made of assessment its performance and efficiency. The paper presents a brief analysis of work and basic relationships in the inverter, the concept of control, conceptual design, difficulties during its implementation and it also identifies sources of power losses in the inverter and determines its efficiency for various load parameters.
PL
W artykule porównano właściwości trzech stałoczęstliwościowych metod sterowania falownika szeregowego do nagrzewania indukcyjnego: ADC, PS- PWM i ACM. Analizę przeprowadzono z wykorzystaniem rozkładu napięcia na wyjściu falownika na składowe harmoniczne. Szczególną uwagę zwrócono na określenie warunków zapewniających przełączanie zaworów przy zerowym napięciu (ZVS) oraz sprawność.
EN
Three fixed-frequency control strategies of a series inverter for induction heating: PS-PWM, ADC and ACM, have been compared in the paper. The analysis has been carried out using decomposition of the inverter output voltage to harmonic components. Special attention has been paid to the determination of conditions assuring ZVS switching of the semiconductor devices and the inverter efficiency.
PL
W artykule podjęto próbę oszacowania efektywności związanej z obowiązkiem jazdy samochodem w dzień z włączonymi światłami na terytorium Rzeczpospolitej Polskiej w kontekście sprawności energetycznej tego procesu. Bazując na danych statystycznych dotyczących wypadków drogowych na terytorium RP oraz cenach budowy nowych odcinków dróg i modernizacji istniejacej infrastruktury drogowej, skonfrontowano te dane ze związanymi z tym kosztami ponoszonymi przez kierowców i kosztami środowiskowymi. Artykuł ma być głosem w dyskusji na temat priotrytetów i kierunków działań zmierzających do podniesienia poziomu bezpieczeństwa panującego na drogach.
EN
This paper presents an attempt of assessment of the effectiveness connected with the obligation of using car lights while driving during the day in the Republic of Poland in terms of energy efficiency of this process. Basing on statistical data concerning car accidents in the Republic of Poland and the prices of construction of new road stretches and modernization of the existing road infrastructure, these data have been confronted with the connected costs borne by car-drivers, and environmental costs. The article is intended to be a contribution to the discussion on the priorities and directions of activities aimed at raising the level of safety on public roads.
13
Content available remote ZVS single-switch inverter for induction heating – optimum operation
EN
The optimum operation of a single-switch class E transistor inverter for induction heating has been discussed in the paper. The graphs of the most important inverter parameters as a function of the values of the resonant circuit components are shown. The results presented have been illustrated with some current and voltage waveforms obtained on the basis of mathematical analysis as well as using IsSpice simulation program. A concept of a control system has also been presented, which should ensure nearly optimum operation of the inverter.
PL
W artykule omówiono pracę optymalną jednołącznikowego tranzystorowego falownika klasy E do nagrzewania indukcyjnego. Przedstawiono wykresy najważniejszych parametrów falownika w funkcji wartości elementów obwodu rezonansowego. Podano przykładowe przebiegi czasowe prądów i napięć w falowniku otrzymane zarówno na podstawie analizy matematycznej, jak i poprzez symulacje w programie IsSpice. Przedstawiono również koncepcję układu sterowania falownika, który powinien zapewniać pracę w warunkach bliskich optymalnym.
PL
W artykule omówiono pracę optymalną jednołącznikowego tranzystorowego falownika klasy E do nagrzewania indukcyjnego. Przedstawiono wykresy najważniejszych parametrów falownika w zależności od wartości elementów obwodu rezonansowego. Są nimi względny czas przewodzenia tranzystora, względna częstotliwość jego przełączania oraz względne warto ści maksymalnego napięcia na tranzystorze, maksymalnego prądu tranzystora oraz mocy falownika. Podane wyniki uzupełniono o przykładowe przebiegi czasowe prądów i napięć w falowniku otrzymane zarówno na podstawie analizy matematycznej, jak i poprzez symulacje w programie Spice. Przedstawiono również koncepcję układu sterowania falownika, który powinien zapewniać pracę w warunkach bliskich optymalnym.
EN
The optimum operation of a single-switch class E inverter for induction heating has been discussed in the paper. The graphs of the most important inverter parameters as a function of the values of the resonant circuit elements are shown. These parameters are: relative conduction time of the transistor, relative switching frequency, and relative values of the maximum voltage across the transistor, maximum transistor's current arid power of the inverter. The results presented have been illustrated with some current and voltage waveforms obtained on the basis of mathematical analysis as well as using Spice simulations. An idea of a control circuit has also been discussed, which should ensure nearly optimum operation of the inverter.
PL
W pierwszej części niniejszego artykułu została przedstawiona topologia jednołącznikowego tranzystorowego falownika napięciowego klasy E w zastosowaniu do nagrzewania indukcyjnego. Omówiono fazy (takty) jego pracy ze specjalnym uwzględnieniem pracy optymalnej. Podano założenia projektowe układu i obliczenia parametrów elektrycznych oraz przykładowe przebiegi czasowe prądów i napięć w falowniku otrzymane poprzez symulacje w programie IsSpice. W części drugiej artykułu zaprezentowano koncepcje układów sterowania falownika, który powinien zapewniać pracę w warunkach bliskich optymalnym, ich weryfikacje na podstawie badań symulacyjnych, zastosowany układ rozruchowy falownika, opis kilku bloków układu sterowania oraz przebiegi otrzymane w zbudowanym modelu falownika.
EN
The first part of this paper presents the topology of a single-switch voltagefed class E transistor inverter applied to induction heating. The modes of its operation with special emphasis on optimum operation have been discussed. The design assumptions and calculations of electrical parameters as well as sample waveforms of currents and voltages in the inverter obtained through simulations in the IsSpice have been presented. The second part of the paper includes: the concepts of the inverter control system, which should provide operation in conditions close to the optimum, their verification on the basis of simulation tests, soft-start system of the inverter, description of some control system blocks and the waveforms obtained experimentally in the model of the inverter.
PL
W artykule przedstawiono topologię jednołącznikowego tranzystorowego falownika napięciowego klasy E w zastosowaniu do nagrzewania indukcyjnego. Omówiono fazy (takty) jego pracy ze specjalnym uwzględnieniem pracy optymalnej. Przedstawiono założenia projektowe układu i obliczenia parametrów elektrycznych oraz przykładowe przebiegi czasowe prądów napięć w falowniku otrzymane poprzez symulacje w programie IsSpice. W części drugiej artykułu zostanie zaprezentowana również koncepcja układu sterowania falownika, który powinien zapewniać pracę w warunkach bliskich optymalnym oraz zostaną przedstawione przebiegi otrzymane w układzie prototypowym.
EN
This paper presents the topology of a single-switch voltage-fed class E transistor inverter applied to induction heating. The modes of its operation with special emphasis on optimum operation are discussed. The paper includes the design assumptions and calculations of electrical parameters and sample waveforms of currents and voltages in the inverter obtained through simulations in the IsSpice. In the second part of the paper the concept of the inverter control will be presented, which should provide inverter operation in conditions close to the optimum operation, and the waveforms obtained in the model of the system will be shown.
PL
Tematem opracowania jest wielomodułowy falownik napięcia z rezonansem szeregowym, w którym można uzyskać częstotliwości prądu rzędu kilkudziesięciu kiloherców przy zastosowaniu tyrystorów szybkich. Istotne jest zastosowanie odpowiednich indukcyjności dodatkowych, co umożliwia znaczne wydłużenie czasu dysponowanego na wyłączenie tyrystorów. Przedstawiono analizę pracy falownika przy częstotliwości prądu odbiornika równej i większej od częstotliwości drgań własnych obwodu szeregowego falownika oraz omówiono jego podstawowe właściwości. Do najważniejszych należą: wymagana minimalna wartość indukcyjności wejściowych, czas dysponowany na wyłączenie tyrystorów, maksymalna wartość napięcia na tyrystorach i kondensatorach oraz moc falownika. Przedstawiony w artykule falownik tyrystorowy może znaleźć zastosowanie jako alternatywa dla falowników tranzystorowych między innymi w układach do nagrzewania indukcyjnego dużej mocy.
EN
The subject of the paper is a multi-module voltage-fed thyristor inverter with series resonance, which enables obtaining output current frequencies of the order of dozens of kilohertz using fast SCRs. A crucial thing is using proper additional inductances, which make it possible to considerably lengthen the time necessary to turn-off the outgoing thyristors. The inverter operation at the frequency equal to or higher than the natural frequency of the inverter series circuit has been dealt with in the paper. Its most important properties have also been discussed. The most important are: the requires value of the inductances, time during which the outgoing thyristors are reverse-biased, the maximum voltage across the thyristors and the capacitors as well as the inverter power. The inverter presented int the paper might be used as in alternative for transistor inverters, among others in high power induction heating applications.
PL
Podczas pracy pieca łukowego ważna jest możliwość ciągłej obserwacji parametrów procesu topienia wsadu. Przedmiotem artykułu jest opracowany system wizualizacji pracy dydaktycznego modelu jednofazowego pieca łukowego, zasilanego napięciem 230 V poprzez transformator i dławik. Model pieca wyposażony jest w sterownik mikroprocesorowy utrzymujący zadaną wartość stosunku napięcia na elektrodzie do prądu łuku. Zastosowano w nim również standardowy wyświetlacz LCD, na którym przedstawiane są aktualne komunikaty. System wizualizacji zrealizowano głównie przy wykorzystaniu bezpłatnych narzędzi informatycznych o otwartym kodzie (Open Source). Wprowadzono także możliwość sterowania pracą pieca z komputera, na monitorze którego wykonywana jest wizualizacja, oraz pomiaru innych wielkości poprzez dodatkowy moduł pomiarowy. Opisany układ umożliwia wizualizację pracy modelu pieca z dowolnego komputera z dostępem do Internetu. Po odpowiedniej modyfikacji może też znaleźć wiele innych zastosowań.
EN
The possibility of monitoring the parameters of the charge melting process is very important during the operation of an arc furnace. The object of the paper is a developed visualization system of a didactic model of a single-phase arc furnace supplied with a line voltage of 230 V via a transformer and a choke. The model is equipped with a microprocessor-based controller maintaining a set ratio of the voltage across the electrode to the arc current. A standard LCD display is used to present the current information. The visualization system has been developed using mainly free software with open source code. Possibilities of controlling the furnace operation from the computer, on which the visualization is performed, and measuring additional quantities via an additional measuring device have also been enabled. The system described enables the visualization of the arc furnace model operation using any computer with access to the Internet. After proper modifications the system can have many other applications.
EN
Possible operation modes of a full-bridge voltage-source series resonant inverter with PFM control used in induction heating have been dealt with in the paper. The mode the inverter is operated at is determined by the ratio of the used operating frequency to the frequency of free oscillations of the series resonant circuit created by the heating coil with workload and the series capacitor. The most important properties of the inverter have been presented like magnitudes of currents, voltages and power as well as conduction times of semiconductor elements, which depend on the selected operation mode. Fundamental requirements for thyristor and transistor inverters have been given.
PL
W artykule przedstawiono możliwe stany pracy sterowanego częstotliwościowo falownika rezonansowego szeregowego napięciowego pracującego w układzie mostkowym stosowanego do nagrzewania indukcyjnego, określone stosunkiem częstotliwości przełączania łączników do częstotliwości drgań własnych obwodu rezonansowego utworzonego przez wzbudnik ze wsadem i kondensator szeregowy. Przedstawiono najważniejsze właściwości falownika, takie jak wartości prądów, napięć i mocy oraz czasy przewodzenia elementów półprzewodnikowych, które są zależne od wybranego stanu pracy. Podano zasadnicze wymagania dla falowników tyrystorowych oraz tranzystorowych.
EN
Assuming constancy of magnetic flux induced in a long coil under both load and no-load condition makes it easier to calculate magnetic field intensity […] at the surface of a workpiece heated by induction. A knowledge of […] makes it possible to analyse various electric quantities in the workpiece. As an example, the real and reactive components of power in the workpiece have been analysed. Conditions that must be met to allow replacing the cylindrical electromagnetic wave with a plane wave have also been given.
PL
Przyjęcie stałości strumienia magnetycznego wytworzonego w długim wzbudniku zarówno pustym, jak i ze wsadem, ułatwia obliczenie pola magnetycznego [...] na powierzchni nagrzewanego indukcyjnie wsadu. Znajomość [...] umożliwia zanalizowanie różnych wielkości elektrycznych występujących we wsadzie. Przykładowo zanalizowano moce czynną i bierną wsadu. Podano też warunki umożliwiające zastępowanie fali elektromagnetycznej walcowej przez falę płaską.