Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The analytical procedure for the determination of lead in tap water has been described. The method comprises an enrichment step (cloud point extraction without chelating agents), and FI-ICP-OES detection. In the initial aqueous solution the analyte was preconcen-trated and introduced into the surfactant rich phase of polyethyleneglycolmono-p-nonyl-phenylether. After the phase separation at the increased temperature, a satisfactory pre-concentration factor (>300) has been achieved. Hydrochloric acid was used for the dilution of the surfactant-rich phase. Several parameters influencing the efficiency and performance of the method were evaluated, i.e. pH of the extraction, extractant volume, composition of the diluent. Recoveries of the spiked (3-20ug L(-1)) doubly distilled water samples were quantitative. Under the optimum conditions, E was higher than 99.9%, and the sensitivity of 0.077 ng L(-1) has been achieved. The results of the analysis of the certified reference material (QC METAL LL2 ) were consistent with the certified values. The proposed method was successfully applied to the determination of lead in tap water samples in San Luis, Argentina.
PL
Opisano metodę oznaczania ołowiu w wodzie wodociągowej. Metoda obejmuje wzbogacanie za pomocą ekstrakcji bez czynników chelatujących oraz oznaczanie techniką przepływowo-wstrzykową z detekcją przy użyciu emisyjnej spektrometrii z indukcyjniesprzężonąplazmą. Próbkę analizowanej wody wstępnie zagęszczano, po czym wprowadzano do fazy bogatej w odczynnik powierzchniowoczynny - polietylenoglikolomono-p-nonylofenyloeter. Po ogrzaniu i rozdzieleniu się faz uzyskano zadowalający współczynnik zatężania (>300). Do rozcieńczania fazy bogatej w odczynnik powierzchniowoczynny użyto kwasu solnego. Zbadano szereg parametrów wpływających na wydajność ekstrakcji, np.: pH, objętość ekstra-howanych faz, skład rozcieńczalnika. Odzyski ołowiu z wody podwójnie destylowanej z wprowadzonym analitem (3-20ug L(-1)) były ilościowe. W optymalnych warunkach osiągnięto wydajność ekstrakcji E powyżej 99% i czułość 0,077 ug L(-1). Wyniki analizy materiału wzorcowego były zgodne z ich specyfikacją. Proponowaną metodę zastosowano z powodzeniem do oznaczania ołowiu w próbkach wody z kranu w San Luis w Argentynie.
EN
An on-line cadmium preconcentration and determination system implemented with inductively coupled plasma atomic emission spectrometry (ICP-AES) associated to flow injection (FI) method was studied. For the retention of cadmium, 2-(5-bromo-2-pyri-dylazo)-5-diethylaminophenol (5-Br-PADAP) and Amberlite XAD-16 were used, at pH 9.5. The cadmium was removed from the micro-column in countercurrent with nitric acid. An enrichment factor of 60 was obtained with respect to ICP-AES using pneumatic nebulization, for the preconcentration of 50 ml of sample solution. The detection limit value for the preconcentration of 50 ml of aqueous solution of Cd was 0.04 ug 1(-1). The precision for 10 replicate determinations at the 5 ng 1(-1) Cd levels was 2.0% relative standard deviation (RSD), calculated with the peak heights obtained. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 100 ug (-1). The method was successfully applied to the determination of cadmium in drinking water samples.
PL
Badano układ do zatężania i oznaczania kadmu za pomocą spektrometrii emisyjnej z indukcyjnie sprzężoną plazmą (ICP-AES) w połączeniu z techniką wstrzykową (FI). Kadm był zatrzymywany na kolumnie z Amberlitem XAD-16 w postaci kompleksu z 2-(5-bromo-2-pirydylazo)-5 dietyloaminofenolem (5-Br-PADAP) przy pH = 9.5. Kadm eluowano z mikrokolumny za pomocą kwasu azotowego stosując kierunek przepływu odwrotny do tego jaki miał miejsce podczas zatężania. Współczynnik wzbogacenia uzyskiwany w metodzie ICP-AES z nebulizacją pneumatyczną przy zatężaniu kadmu z 50 ml wodnego roztworu wynosił 60. Granica wykrywalności dla tych warunków wynosiła 0.04 mg 1~'. Precyzja obliczona dla 10 powtórzeń oznaczenia kadmu na poziomie stężeń kadmu 5 mg P1, obliczona z wysokości piku i wyrażona za pomocą względnego odchylenia standardowego (RSD), wynosiła 2%. Krzywa kalibracyjna przy zastosowaniu powyższego sposobu zatężania kadmu i dla zakresu stężeń od stężenia bliskiego granicy detekcji do 100 mg T1 była liniowa ze współczynnikiem korelacji 0.9995. Powyższą metodę zastosowano z powodzeniem do oznaczania kadmu w próbkach wody pitnej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.