Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This study examined the interface pressure differences at the stump socket between an ICRC polypropylene socket and an air splint socket for a common wearer of transhumeral amputee using F-socket transducers. Two F-socket sensors arrays were attached to the residual limb. The subject was asked to complete the following tasks: Normal position, stand in a normal position without conducting any motion and shoulder movements, flexion/extension and abduction. The results revealed that the interface pressure applied using ICRC polypropylene socket was maximize at the end distal of the residual limb and give more pressure contact to any shoulder movements. Conversely, while using air splint socket, the socket was able to auto-adjust for required socket fitting even for any change while doing shoulder movements. Our result demonstrated how the comparison of pressure applied at the stump socket may lead in chosen the suitable prosthetic's socket for the amputee. The impending development of an auto-adjusted socket that uses an air splint system will provide the prosthetic socket with a less contact pressure at the residual limb.
EN
Conventionally, patellar tendon-bearing (PTB) sockets, which need high dexterity of prosthetist, are widely used. Lack of chartered and experienced prosthetist has often led to painful experience of wearing prosthesis and this will in turn deter the patients to wear the prosthesis, which will further aggravate stump shrinkage. Thus, the hydrostatic socket which demands relatively lower level of fabricating skill is proposed to replace the PTB socket in order to produce the equivalent, if not better, quality of support to the amputee patients. Both sockets' pressure profiles are studied and compared using finite element analysis (FEA) software. Three-dimensional models of both sockets were developed using MIMICS software. The analysis results showed that hydrostatic socket did exhibit more uniform pressure profiles than that of PTB socket. PTB socket showed pressure concentration near the proximal brim of the socket and also at the distal fibula. It was also found that the pressure magnitude in hydrostatic socket is relatively lower than that of PTB socket.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.