EN
Ambient concentrations of CO, as well as NOx and O3, were measured as a part of the PARADE campaign conducted at the Taunus Observatory on the summit of the Kleiner Feldberg between the 8th of August and 9th of September 2011. These measurements were made in an effort to provide insight into the characteristics of the effects of both biogenic and anthropogenic emissions on atmospheric chemistry in the rural south-western German environment. The overall average CO concentration was found to be 100.3±18.1 ppbv (within the range of 71 to 180 ppbv), determined from 10-min averages during the summer season. The background CO concentration was estimated to be ~90 ppbv. CO and NOx showed bimodal diurnal variations with peaks in the late morning (10:00-12:00 UTC) and in the late afternoon (17:00-20:00 UTC). Strong correlations between CO and NOx indicated that vehicular emission was the major contributor to the notable CO plumes observed at the sampling site. Both local meteorology and backward trajectory analyses suggest that CO plumes were associated with anthropogenically polluted air masses transferred by an advection to the site from densely populated city sites. Furthermore, a good linear correlation of R2 = 0.54 between CO and O3 (∆O3/∆CO=0.560±0.016 ppbv/ppbv) was observed, in good agreement with previous observations.
2
Content available remote Mechaniczna aktywacja dwuwodnego siarczanu wapnia
PL
Zbadano wpływ mechanicznej aktywacji gipsu dwuwodnego na jego efektywność przyspieszania wiązania półwodzianu. Stwierdzono, że duże znaczenie ma zanieczyszczenie surowca gipsowego twardymi minerałami, przede wszystkim kwarcem. Drobne mielenie w takich warunkach powoduje uzyskanie bardzo drobnych cząstek gipsu, częściową amorfizację i zdefektowanie ich sieci krystalicznej. Odgrywają one rolę zarodków przyspieszając bardzo efektywnie wiązanie gipsu. Proponuje się zbadanie wpływu młyna wibracyjnego w większej skali.
EN
The mechanical activation of gypsum upon the effectiveness of its action as setting accelerator of plaster of Paris. It was found that the great influence has the impurities in natural gypsum, chiefly in the case of harder minerals among others quartz. Fine grinding of this gypsum leads to the formation of very small gypsum particles, their partial amorphisation and formation of several defects in their crystal lattice. They play a role of nuclei drastically accelerating the hemihydrate setting. In order to estimate the effectiveness of vibratory disc mill the tests in a larger scale are proposed.
3
Content available remote Bacterial leaching of nickel and cobalt from pentlandite.
EN
The influence of Thiobacillus ferrooxidans bacteria on efficiency of nickel and cobalt leaching from natural pentlandite (Ni,Fe)9S8 have been examined. The effect of pulp density, particle size and initial ferrous ion concentration in leaching solution. on the leaching yield was also evaluated. It has been demonstrated that the presence of T.ferrooxidans bacteria in leaching system induced considerable increase in nickel and cobalt leaching from pentlandite. The decrease in efficiencies of nickel and cobalt bacterial leaching processes have been denoted in systems containing. high amounts of ferrous ions. Initial Fe2+ concnentarion of 4.5 g/dm3 seems to be the most favorable for pentlandite bioleaching. The 20% pulp density may be admitted to be optimum regarding both satisfactory yields of bioleaching process and high nickel and cobalt concentrations in leaching solutions. The obtained results showed that particle size of 90-125 m was optimum for nickel and cobalt bioleaching from pentlandite.
PL
Badano wpływ bakterii Thiobacillus ferrooxidans na efektywność ługowania niklu i kobaltu z naturalnego pentlandutu (Ni, Fe)9S8, zawierającego 5,21% Ni 51.10% FE i 0.25% Co. Oceniano także wpływ gęstości pulpy (1%, 5%, 20%), rozmiaru ziaren (36-63 mm, 90-125 mm, 200-250mm, 63-200um) i początkowego stężenia jonu żelazawego Fe(II) w roztworze ługujacym (4,5 g/dm3, 9,0g/dm3, 13.5 g/dm3) na wydajność ługowania. Wykazano, że obecność bakterii T. Ferrooxidans w układzie ługujacym powodowała istotne zwiększenie wyługowania niklu i kobaltu z pentlandytu. W układach zawierających wysokie stężenie jonów żelazawych (?9 g/dm3)odnotowano zmniejszenie efektywności procesów bakteryjnego ługowania niklu i kobaltu. Wydaje się, że najbardziej korzystne dlabioługowania pentlandytu jest początkowe stężenie Fe(II) wynoszące 4.5 g/dm3. Biorąc pod uwagę zarówno satysfakcjonujące wydajności procesów bioługowania, jak i wysokie stężenia niklu i kobaltu w roztworach ługujacych, można przyjąć 20%-ową gęstość pulpy jako otymalną. Wielkość ziaren pentlandytu, optymalna dla bioługowania nuklu i kobaltu z tego minerału, powinna mieścić się w zakresie 90-125mm.
PL
Badano przebieg chemicznej reakcji i biologicznej ekstrakcji niklu z pentlandytu (Ni, Fe)9S8 i wykazano istotny wpływ regulacji odczynu pH rozworu ługującego na efektywność tych procesów. Regulacja pH była korzystna w przypadku procesów chemicznych (prowadzonych w warunkach sterylnych), kiedy nie zachodzą biochemiczne procesy utleniania siarki (uwalnianej z materiałów siarczkowych do kwasu siarkowego zużywanego w chemicznych procesach roztwarzania siarczków metali. Korekta pH nie jest wskazana dla procesów przebiegających w obecności bakterii Thiobaciillus ferroxidans, których aktywność metaboliczna prowadzi do zakwaszania środowiska ługowania.
EN
The influence of pH-adjustment in leaching solution on chemical an biological extraction of nickel from pentlandite (Ni, Fe)9S8 has been investigated. It was demonstrated that regulation of pH may be favourable for chemical processes carried out in sterile conditions, when biochemical processes of sulphur oxidation to sulphuric acid do not take place. Adjustment of pH in the leaching systmes is not recommended to sulphuric acid do not take place. Adjustment of pH in the leaching systems is not recommended in processes carried out in the presence of bacteria Thiobacillus ferrooxidans basause bacterial metabolic activity contributes to acidification of leaching environment.