This study demonstrates that integrated management and direct control systems may be combined into integrated enterprise process control (EntPC) systems, which are composed of self-controlling enterprise business processes. A business process has been defined as a control system for business activities, which are considered to be business processes of the lower level, or as base processes that are control systems for control plants in the form of infrastructure operations. An enterprise process also influences its delivery. This description of a business process is usually compared with definitions used in such approaches as BPMN, YAWL, ARIS and DEMO and MERODE. Each enterprise process has its own controlling unit that contains one information unit and one decision unit, as well as memory places of the information-decision state variables that are processed by the business transitions that belong to these units. The i-d state variables are attributes of business objects, i.e. business units, business roles, business activities, business accounts and business products. Their values are transferred between business transitions that belong to the same or different controlling units. Relationships between business objects, business transitions and i-d state variables, as well as the other most important concepts of the EntPC system framework (EntPCF), are presented in this paper as the class diagrams of the enterprise process control language (EntPCL).
PL
W pracy przedstawiono teorię EPC (Enterprise Process Control) jako opis nowego modelu ontologicznego zintegrowanych systemów zarządzania i sterowania bezpośredniego. Pokazano, że model ten, oparty na modelu informacyjnodecyzyjnym procesów biznesowych, można uważać za modyfikację i rozszerzenie znanej ontologii przedsiębiorstw opartej na teorii PSI (Performance in Social Interaction), leżącej u podstaw metodologii DEMO (Design and Engineering Methodology for Organizations).
EN
The paper presents the EPC theory (Enterprise Process Control) as a description of a new ontological model of integrated management and direct control systems. It was shown that this model, based on the information-decision model of business processes, may be regarded as a result of modification and extension of the well-known enterprise ontology based on the PSI theory (Performance in Social Interaction), which underlies the DEMO (Design and Engineering Methodology for Organizations).
PL
Badano aktywność katalizatora tlenkowego żelazowo- chromowego (TZC 3/1) i palladowego zawierającego 1% Pd na warstwie pośredniej z γ-Al₂O₃ w reakcji całkowitego utlenienia wodzianu aldehydu 1,1,1-trichlorooctowego (wodzianu chloralu), dozowanego jako modelowy roztwór wodny o stężeniu 50 g/L. Analizowano gazowe i ciekłe produkty utlenienia substratu, uzyskiwane w zakresie temp. 300-550°C i w czasie kontaktu reagentów z katalizatorem 0,36 s. Stwierdzono, że praktycznie całkowite utlenienie wodzianu chloralu można uzyskać w temp. 450°C z udziałem obydwu katalizatorów. Zawartość dioksyn w spalinach otrzymanych w wybranych temperaturach doświadczeń nie przekroczyła wartości dopuszczalnej międzynarodowego równoważnika toksyczności (international toxicity equivalent) wynoszącej 0,1 ng/m³. Uzyskane wyniki świadczą o możliwości obniżenia temperatury unieszkodliwiania substratu jako modelu odpadów chloroorganicznych do 450-550°C, z udziałem badanych katalizatorów w stosunku do procesu realizowanego w przemyśle w zakresie 1100-1500°C.
EN
An aq. soln. of Cl₃CCHO•H₂O (50 g/L) was oxidized with air O₂ in an elec. heated tubular reactor over (i) Fe-Cr and (ii) Pd catalysts at 300-550°C to CO₂, HCl and H₂O. The oxidn. was completed at (i) 450°C and (ii) 550°C after 0.36 s. The substrate was supplied to an evaporator (mass flow rate of 29-32.5 g/h) at air stream 200 L/h. CH₂O and Cl⁻ concns. and total org. C were detd. in liq. reaction products. In the combustion gases, CO, Cl₂ and CH₂O were found. The content of polychlorinated dibenzodioxines and furanes did not exceed the admissible value of international toxicity equiv. (0.1 ng/m³) in the combustion gases.
PL
Omówiono konstrukcję, technologię i parametry dwóch nowych typów detektorów do systemu detekcyjnego ALBEGA (ALfa – BEta – GAmma) budowanego w GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (GSI), przeznaczonego do badań nad transaktynowcami. Detektor alfa stanowi 64-elementowa przepływowa matryca monolityczna zbudowana z dwóch płytek krzemowych o typie przewodnictwa ν, w których wytrawiony jest kanał, przez który przepływają (w gazie nośnym) badane substancje. Od strony kanału na całej powierzchni płytek wytworzony jest techniką dyfuzji fosforu obszar n+ (wspólna katoda). Na stronie przeciwległej do kanału wytworzone są techniką selektywnej dyfuzji boru 32 złącza p+-ν. Po połączeniu płytek powstaje szczelny kanał (przewód gazowy). Do jednego z końców tego przewodu doprowadzany jest gaz nośny (hel) zawierający atomy badanych pierwiastków promieniotwórczych. Gaz ten przepływa przez kanał. Promieniowanie jonizujące, emitowane przez atomy transportowane w gazie nośnym wnika do krzemu. Nośniki ładunku generowane w krzemie przez absorbowane promieniowanie (głównie cząstki alfa) są rozdzielane przez najbliższe złącze p+-ν, powodując powstanie sygnału elektrycznego. Promieniowanie beta i gamma przechodzi przez krzem i może być detekowane przez detektory odpowiednio umieszczone na zewnątrz przepływowego detektora cząstek alfa. Detektor beta stanowi monolityczna, 32-elementowa matryca o średnicy obszaru czynnego 90 mm, o grubości 0,9 mm. Materiałem wyjściowym jest wysokorezystywna płytka krzemowa typu ν. Na górnej stronie tej płytki wykonane są poprzez dyfuzję boru 32 planarne złącza p+-ν. Na dolnej stronie wykonany jest na całej powierzchni, poprzez dyfuzje fosforu, obszar n+, stanowiący wspólną katodę.
EN
The paper presents the design, technology and parameters of two new types of silicon detectors for the new detection system ALBEGA (ALfa – BEta – GAmma). The ALBEGA system will be used for research on transactinide elements at the GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (GSI) The alpha detector is a 64-element silicon monolithic flow array. The array consisting of two ν-type silicon wafers with a channel etched into them, through which the studied substances flow (in carrier gas), is used in the detector. An n+ region (common cathode) is formed by the phosphorous diffusion over the entire surface of the wafers from the side of the channel. 32 p+ regions (anode regions) are formed by selective boron diffusion on the side opposite to the channel. After the wafers are bonded, an gas-tight channel (gas pipe) is formed. Carrier gas (noble gas or a mixture of noble gas and reactive gas) containing atoms of radioactive elements under study is introduced into one end of this pipe. The gas flows through the channel and exits at the other end of the pipe. The transported active atoms/molecules are adsorbed inside the pipe and undergo the radioactive decay. The ionising radiation emitted by the atoms transported by the carrier gas penetrates into silicon. The charge carriers generated in silicon by absorbed radiation (mainly alpha particles) are separated by the nearest p+-ν junction, creating an electric signal. Beta and gamma radiation passes through silicon and can be detected by the detectors appropriately placed outside the flow alpha detector. The beta detector consists of a monolithic 32-element array with an active area diameter of 90 mm and a thickness of 0.9 mm. The starting material is a high-resistivity n silicon wafer. 32 planar p+-ν junctions are formed by boron diffusion on the top side of the wafer. On the bottom side, an n+ region, which forms a common cathode, is formed on the entire surface by phosphorus diffusion.
8
Content available remote Strategia termomodernizacji budynków w Polsce
9
Content available remote Development of REFET for Differential Measurements of pH in a Fluidic System
EN
This paper describes the fabrication of the REFET structure by means of plasma oxidation of silicon nitride and discusses the results of differential pH measurements and quasi-REFET characterization. The source follower measurement circuit and housings for the fluidic systems are shown. The pH measurement of the diluted hydrochloric acidis presented as an exemplary application.
PL
W pracy przedstawiono dotychczasowy rozwój technologii REFETów. Opisano wytwarzanie REFETa metodą utleniania plazmowego warstwy azotkowej. Zaprezentowano układ pomiarowy wtórnika źródłowego i obudowy przepływowe. Podano wyniki kwalifikacji kwazi-REFETów i różnicowych pomiarów pH. Zaproponowano zastosowanie przyrządu wraz z pseudoreferencyjną elektrodą Pt do pomiarów w rozcieńczonym HCl.
EN
The subject of the investigation was the model solution containing 50 g/dm3 waste light ends from PVC production, dissolved in the ethanol-water (1:1) mixture. The main components of light ends were as follows: trichloromethane, tetrachloromethane, and chloroderivatives of ethane. Granular ferric-chromic catalyst (TZC 3/1) was used in the investigation. The temperature range applied in experiments was 400-600oC and the contact time was 0.27 s. Gaseous products of the reaction were analysed in order to determine among others concentration of chlorine, formaldehyde, oxygen, carbon monoxide and dioxins. The content of total organic carbon (TOC), chloride ions and formaldehyde was determined in a condensate. Oxidation of the mixture proceeded in the all temperature range with high efficiency in regard to initial TOC value of the solution. The concentration of dioxins in the combustion gases obtained in the process carried out in temperature 450oC amounted to 0.021-0.027 ng TEQ/m3, and was significantly lower than the admissible value of 0.1 ng TEQ/m3. Congeners of polychlorinated dibenzofuranes (PCDFs) predominated in the combustion gases. Tested catalyst did not undergo deactivation during 150 h substrate oxidation.
PL
Przedmiot badań stanowił roztwór modelowy zawierający 50 g/dm3 frakcji lekkiej odpadów z produkcji PCW w mieszaninie etanol-woda (1:1). Głównymi składnikami odpadu były: trichlorometan, tetrachlorometan i chloropochodne etanu. Natężenie przepływu powietrza wynosiło 300 dm3/h, substratu 16 g/h, a czas kontaktu 0,27 s. Zakres temperatury doświadczeń wynosił 400-600oC. Stosowano ziarnisty katalizator żelazowo-chromowy TZC 3/1. W gazowych produktach reakcji oznaczano m.in. stężenie chloru, formaldehydu, tlenu i tlenku węgla, natomiast w kondensacie zawartość ogólnego węgla organicznego (OWO), jonów chlorkowych, formaldehydu i dioksyn. Utlenienie substratu zachodziło w zakresie temperatury 400-600°C bardzo wydajnie względem początkowego OWO tych roztworów. Stężenie PCDD/Fs w spalinach w procesie realizowanym w temperaturze 450oC wynosiło 0,021-0,027 ngTEQ/m3 i było znacznie mniejsze od wartości dopuszczalnej 0,1 ngTEQ/m3. W spalinach dominowały kongenery polichlorowanych dibenzofuranów (PCDFs). Badany katalizator nie uległ dezaktywacji w okresie 150 h utleniania substratu.
PL
Praca dotyczy związków agregacyjnych między rodzajami zasobów i ich kategoriami, rodzajami czynności i ich grupami organizacyjnymi, zbiorczymi zamówieniami zakupu i pozycjami tych zamówień, transakcjami złożonymi i ich transakcjami składowymi itp. Omówiono strukturę tabel zawierających informacje o tych związkach w informatycznych systemach zarządzania i pokazano, że wiele z nich można zapisać jako zależności funkcyjne w tabelach bytów agregowanych.
EN
The paper deals with aggregation relationships between resource kinds and their categories, activity kinds and their organizational groups, purchase orders and their items, complex and component transactions and the like. The structure of the tables containing information on these relationships in computer management systems has been discussed. It was shown that many of such relationships may be recorded as function dependencies in the tables of the aggregated entities.
EN
The subject of the investigation was the model solution containing 50 g/dm3 waste light ends from PVC production dissolved in the ethanol-water (1:1) mixture. Granular ferric-chromic catalyst (TZC 3/1) was used in the investigation. The temperature range applied in experiments was 400÷600ºC and the contact time was 0.27 s. Gaseous products of the reaction were analysed in order to determine among others concentration of chlorine, formaldehyde, oxygen, carbon monoxide and dioxins. The content of total organic carbon (TOC), chloride ions and formaldehyde was determined in a condensate. Oxidation of the mixture proceeded in the all temperature range with high efficiency in regard to initial TOC value in the solution. The concentration of dioxins in the combustion gases obtained in the process carried out in temperature 450ºC amounted to 0.027 ngTEQ/m3, and was significantly lower than the admissible value of 0.1 ngTEQ/m3.
PL
Przedmiot badań stanowił roztwór modelowy 50 g/dm3 frakcji lekkiej odpadów z produkcji PVC w mieszaninie etanol-woda (1:1). Stosowano ziarnisty katalizator żelazowo-chromowy TZC 3/1. Zakres temperatury doświadczeń wynosił 400÷600ºC, a czas kontaktu 0,27 s. W gazowych produktach reakcji oznaczano m.in. stężenie chloru, formaldehydu, tlenu i tlenku węgla oraz dioksyn, natomiast w kondensacie zawartość ogólnego węgla organicznego (OWO), jonów chlorkowych, formaldehydu. Utlenienie badanej mieszaniny zachodziło bardzo wydajnie w całym zakresie temperatury doświadczeń względem początkowego OWO tego roztworu. Stężenie PCDD/Fs w spalinach w procesie realizowanym w temperaturze 450ºC wynosiło 0,027 ng TEQ/m3 i było znacznie niższe od wartości dopuszczalnej 0,1 ng TEQ/m3.
EN
The 1 to 1 relationships of charts of accounts, accounting journals and tables of accounting records with corresponding tables of accounts, business transactions and transactional records in the framework EPC II system have been presented in the paper. These tables are the main information kinds, that is tables in which one can write down all information needed for management and business process control in any enterprise, or they are composed of them. In this way it has been shown that the Theory of Enterprise Process Control is compatible with generally accepted accounting principles. This analysis is an example of demonstrating conformity of the EPC II theory with real management and process control systems. The main information kinds with their key attributes were taken from the complete list of them, which is included in the paper. What is more, the tight relationships between resource flow in business processes and turnover on the accounts of the framework EPC II system have been discussed. Owing to these relationships one can determine the impact of any decision variable on the accounting records in a given enterprise.
PL
Opracowane zostały trzy rodzaje sensorów woltamperometrycznych na podłożach mono-Si. W pracy opisano proces technologiczny ich wytwarzania. Zaprezentowano zdjęcia skaningowe powierzchni Au i AgCl oraz zdjęcia struktur sensorowych. Struktury zostały scharakteryzowane elektrochemicznie w testach redoks.
EN
Three types of voltamperometric chemical sensors have been developed on mono-Si substrates. A process of fabrication is described in the paper. Au and AgCl surface SEM examination together with sensor chip images are presented. Chips have been electrochemically characterized in redox tests.
EN
Polluted air in a big farm of poultry keeping (~18 thousands of chickens) and milker cows (30 animals) in Lodz province was sampled. The aim of the investigation was to determine odour pollutants, especially ammonia, in air and check the possibility of a catalytic method application in their removal. Gas samples were analyzed on the spot of sampling with an application of gases analyser Madur GA-20, as well as in a laboratory with an application of instrumental and spectrophotometric methods. The intensity of odours was estimated using five-stage scale applied by local authorities in Japan for odorous protection of air quality. Within sampling period, poultry keeping in the farm was the source of variable in time ammonia emission ranging from 0.82 to 2.65 mg/m3. Air inside the farm contained carbon dioxide (0–0.3 %) and oxygen (20.5–20.9 %). Carbon monoxide, sulphur dioxide, hydrogen sulphide (> 2.0 mg/m3) and formaldehyde (> 0.25 mg/m3) was not detected. The highest odour intensity inside the building of chicken keeping and at outlets of ventilators was at the third stage in odour scale applied in Japan (3.5), ie, clearly perceptible. However, it decreased significantly with the increase in a distance from the building. Higher ammonia concentrations were determined inside a cowhouse with milker cattle. They ranged from 3.2 to 5.6 mg/m3. Ammonia temporary concentration determined during removal of manure was higher and totalled 15.5 mg/m3. Its highest value (18.8 mg/m3) was determined in gases above slurry in the septic tank.
PL
Wykonano pobory próbek zanieczyszczonego powietrza z dużej fermy drobiu rzeźnego (~18 tys. kurcząt) oraz budynku hodowli bydła mlecznego (30 zwierząt) w województwie łódzkim. Celem badań było wykonanie analiz powietrza na zawartość zanieczyszczeń odorowych, zwłaszcza amoniaku, a w perspektywie zbadanie możliwości zastosowania metody katalitycznego utleniania do ich usuwania. Próbki gazów były analizowane na miejscu pobierania za pomocą automatycznego analizatora gazów Madur GA-20, a także w laboratorium metodami instrumentalnymi i spektrofotometrycznymi. Do oceny intensywności zapachu zastosowano pięciostopniową skalę wykorzystywaną przez władze lokalne w Japonii do ochrony zapachowej jakości powietrza. Hodowla drobiu w badanej fermie była w okresie pobierania źródłem zmiennej w czasie emisji amoniaku w granicach 0,82-2,65 mg/m3. W powietrzu obiektu stwierdzono 0-0,3 % ditlenku węgla i 20,5-20,9 % tlenu, natomiast nie wykryto tlenku węgla, ditlenku siarki, siarkowodoru (> 2,0 mg/m3) ani formaldehydu (> 0,25 mg/m3). Największa intensywność zapachu wewnątrz budynku hodowli kurcząt, a także na wylotach wentylatorów była w trzecim stopniu skali zapachu stosowanej w Japonii (3,5), tj. wyraźna, jednak znacznie obniżała się wraz z oddalaniem się od obiektu. Znaczniejsze były stężenia amoniaku w powietrzu budynku hodowli bydła mlecznego, które mieściły się w zakresie 3,2-5,6 mg/m3. Wyższe było stężenie chwilowe amoniaku podczas usuwania obornika 15,5 mg/m3, a najwyższe w gazach nad gnojowicą w zbiorniku szamba 18,8 mg/m3.
PL
Szkieletowy system sterowania procesami przedsiębiorstwa (system EPC II) jest systemem bazodanowym z relacyjną bazą danych. Te jej tabele, które nie są podklasami innych tabel, nazwano "rodzajami informacji". W pracy przedstawiono wykaz wszystkich atrybutów kluczowych rodzajów informacji oraz zestawienie wszystkich rodzajów informacji z ich atrybutami kluczowymi. Zgodnie z tezą o uniwersalności szkieletowego systemu EPC II dla każdej tabeli każdego informatycznego systemu zarządzania o relacyjnej bazie danych, istnieje związek 1 do 1 z jednym z rodzajów informacji należących do tego zestawienia.
EN
The framework Enterprise Process Control (EPC II) system is a system with a relational database. Those of its tables which are not subclasses of other tables have been named "information kinds". The list of all key attributes of information kinds as well as the list of combinations of all information kinds with their key attributes have been presented in the paper. According to the thesis of universality of the framework EPC II system for each table of each real integrated management system there is a 1 to 1 association with one of information kinds belonging to this list.
PL
Katalizatory ziarniste są dość powszechnie stosowane w procesach kontaktowego oczyszczania gazów odlotowych i powietrza z toksycznych i złowonnych związków organicznych, w tym chloru oraz siarki i azotu [1÷8]. Utlenianie związków wymienionych jako pierwsze skutkuje emisją chlorowodoru i chloru, natomiast drugich emisją tlenków siarki i azotu. Szkodliwe produkty utleniania, jeżeli ich stężenia przekraczają dopuszczalne normy, muszą być usuwane ze spalin, co można realizować metodami konwencjonalnymi. Oddzielnym problemem jest możliwość powstawania i emisji polichlorowanych dibenzo-p-dioksyn oraz polichlorowanych dibenzofuranów (PCDD/Fs), uważanych za związki wysoce niebezpieczne dla ludzi i środowiska naturalnego [9÷11]. W Polsce, aby zapobiegać powstawaniu tych ksenobiotyków, spalanie bezkatalityczne odpadów przemysłowych realizuje się w stosując wysoką temperaturę około 1350°C, długi czas reakcji rzędu 2,5 s oraz szybkie schładzanie spalin [12, 13]. Warunki te pozwalają na utrzymanie równoważnika toksyczności PCDD/Fs na poziomie niższym od 0,1 ng TEQ/m3, wymaganym przepisami prawa [14, 15]
EN
Results of activity investigation of a granular catalyst containing Pd (1%) at -Al2O3 carrier in the oxidation process of selected chloroorganic compounds occurring in liquid industrial wastes was analysed. The following compounds were used as substrates: 1,3-dichloro-2-propanol, chloroacetone, 1,1,1-trichloroacetic aldehyde (chloral), tetrachloromethane, 1,1,1-trichloroethane, 1,1,2-trichloroethane and 1,1,2,2-tetrachloroethane. The temperature range was from 250 to 600°C and the contact time was 0.36 s. Gaseous and liquid reaction products were analysed including the content of dioxins (PCDD/Fs) determination in combustion gases. Total oxidation of the substrates in the presence of the catalyst was found in the temperature range of 375÷550°C. The final products of the substrates oxidation were as follows: carbon dioxide, water vapour and dilute hydrochloric acid. Formaldehyde, carbon monoxide and chlorine were the intermediate products of this reaction. Trace presence of several polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofuranes (PCDD/Fs) was determined. The toxicity equivalent of combustion gases sampled in the temperature of 450-550oC was in the range from 0.0087 to 0.0247 ng TEQ/m3 and was compatible with the admissible values in combustion gases, required by law regulations (0.1 ng TEQ/m3). Results of the investigation prove the possibility of the decrease in the temperature to 450÷550°C during the chloroderivates treatment with the application of the palladium catalyst in comparison with a high-temperature process carried out in the temperature of about 1350°C in industrial plants nowadays.
EN
Polluted air in a big farm of poultry keeping (~18 thousands of chickens) in Lodz province was sampled. The aim of the investigation was to determine odour pollutants, especially ammonia, in air and check the possibility of a catalytic method application in their removal. Gas samples were analyzed on the spot of sampling with an application of gases analyser Madur GA-20, as well as in a laboratory with an application of instrument and spectrophotometric methods. The intensity of odours was estimated using five-stage scale applied by local authorities in Japan for odorous protection of air quality. Within sampling period, poultry keeping in the farm was the source of variable in time ammonia emission ranging from 0.82 to 2.65 mg/m3. Air inside in farm contained carbon dioxide (0÷0.3%) and oxygen (20.5÷20.9%). Carbon monoxide, sulphur dioxide, hydrogen sulphide (> 2.0 mg/m3) and formaldehyde (> 0.25 mg/m3) was not detected. The highest odour intensity inside the building of chicken keeping and at outlets of ventilators was at the third stage in odour scale applied in Japan (3.5), ie, clearly perceptible. However, it decreased significantly with the increase in a distance from the building.
PL
Próbki zanieczyszczonego powietrza z dużej fermy drobiu rzeźnego (~18 tys. kurcząt) pobrano w województwie łódzkim. Celem badań było wykonanie analiz powietrza na zawartość zanieczyszczeń odorowych, zwłaszcza amoniaku, a w perspektywie zbadanie możliwości zastosowania metody katalitycznego utleniania do ich usuwania. Próbki gazów były analizowane na miejscu pobrania za pomocą automatycznego analizatora gazów Madur GA-20, a także w laboratorium metodami instrumentalnymi i spektrofotometrycznymi. Do oceny intensywności zapachu stosowano pięciostopniową skalę wykorzystywaną przez władze lokalne w Japonii do ochrony zapachowej jakości powietrza. Hodowla drobiu w badanej fermie była w okresie pobrania próbek źródłem zmiennej w czasie emisji amoniaku w granicach 0,82÷2,65 mg/m3. W powietrzu obiektu stwierdzono 0÷0,3% ditlenku węgla i 20,5÷20,9% tlenu, natomiast nie wykryto tlenku węgla, ditlenku siarki, siarkowodoru (> 2,0 mg/m3) ani formaldehydu (> 0,25 mg/m3). Najwyższa intensywność odorowa wewnątrz budynku hodowli kurcząt, a także na wylotach wentylatorów mieściła się w trzecim stopniu skali zapachu stosowanej w Japonii (3,5), tj. wyraźny, jednak znacznie obniżała się wraz z oddalaniem się od obiektu.
19
Content available remote The EPC II theory. The structure of business process control systems
EN
The paper is the third one of publications on the EPC theory. The acronym EPC has been replaced with EPC II to avoid confusing Enterprise Process Control with Event-driven Process Chain, which is a well known method of modeling process structures. Basic notions of the EPC II theory have been discussed in the paper using the example of a two-level business process, which is an educational model of production of housing parts of the final product in a household goods factory. For the higher level the follow-up production control system has been presented. For the lower level the central control of a business process has been discussed. For all examples tables of their relational models have been shown. The paper presents the EPC II notation for graphical modeling business processes and their control systems. It uses only 4 symbols from UML activity diagrams - structured activity, action, data store and object flow. It has been shown that business process models, expressed with notations of UML, BPMN, EPC, CPN may be always transformed to EPC II activity diagrams. What is more, with EPC II notation one can present not only structure of business processes in any organizational level of an enterprise, but also structure of their control systems.
20
EN
In the paper the basic concepts of the theory of Enterprise Process Control (EPC II), as well as its most important results and directions of future work, have been discussed. It has been shown that in the synthetic picture of EPC II data structure every structural attribute of information elements may be assigned to one of the three general dimensions: knowledge on kinds of processes and resources, enterprise organization and labels of executions of definite business processes. Differences in concepts of business processes, resources and organizational units between the EPC II theory and the current standards have been pointed out. It has been demonstrated that the framework functional structure of integrated management systems is the same for every organizational level. The notions of business transactions have been introduced and then relationships between functional activities and business transactions have been described. Next, the relationships of bookkeeping accounts, entries and transactions with corresponding notions of the EPC II theory have been discussed. It has been shown how the EPC II theory may be applied to solving certain difficult problems of business process control, including the problem of building a universal framework system of management and process control and the problem of automatic adaptation of management systems software to structural changes of business processes.