Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 18

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The addition of a new source of active power to an electric power distribution network alters its operation conditions. The effect of such changes depends on the power of the additional source, its location in the network as well as its type. In the paper the influence of the active power source on the selected parameters of the operations of the distribution network – such as the active power losses and voltage levels – is presented. Also, the influence of the level of power of the additional source and the level of the network’s load on the location of tie points is considered.
PL
Instalacja dodatkowego źródła mocy czynnej w elektroenergetycznej sieci rozdzielczej zmienia warunki jej pracy. Efekt zmian zależy od mocy dodatkowego źródła, miejsca jego lokalizacji w sieci oraz rodzaju przyłączanego źródła. W pracy analizuje się wpływ źródła mocy czynnej na wybrane parametry pracy sieci dystrybucyjnej takie jak straty mocy czynnej i poziomy napięć. Dokonano analizy wpływu mocy przyłączanego źródła i poziomu obciążenia sieci na lokalizację stałych punktów podziału sieci.
PL
Elektroenergetyczne sieci rozdzielcze średniego napięcia (SN) mają struktury otwarte lub zamknięte, przy czym zawsze pracują w konfiguracjach otwartych. W torach głównych linii instalowane są łączniki umożliwiające realizację stałych podziałów w sieci, tzw. rozcięć. W referacie przedstawia się sposób określenia najlepszych lokalizacji rozcięć w sieci rozdzielczej średniego napięcia przy założeniu zmienności obciążeń w analizowanym okresie. Przyjętym kryterium lokalizacji rozcięć jest minimalizacja strat mocy czynnej w sieci. Do rozwiązania przedstawionego problemu zastosowano algorytm ewolucyjny. W artykule przedstawia się przykład obliczeniowy ilustrujący zastosowanie opracowanego programu komputerowego.
EN
The MV networks mostly forms a closed structures, but operates in an open configuration. In the distribution feeders there are installed switches that enable the realization of permanent divisions of the network (tie-points). The paper presents the method to determine the best location of the tie-points in the MV distribution network, assuming the network load changes in the optimization period. The criterion of tie-points location is minimization of active power losses in the network. The optimization task were solved with using evolutionary algorithm. The paper presents a calculation example that illustrates the use of a developed computer program.
PL
Optymalizacja promieniowych struktur sieci elektroenergetycznych należy do problemów NP - trudnych. Funkcją celu analizowanego problemu stanowią koszty roczne struktury sieci elektroenergetycznej (roczny koszt inwestycyjny i zmienny). Do poszukiwania rozwiązań suboptymalnych zaproponowano metodę wykorzystującą algorytm genetyczny i algorytm symulowanego wyżarzania. Oba algorytmy optymalizują (minimalizują) tą samą funkcję celu. Uzyskanie takich samych rozwiązań dwoma algorytmami zwiększa prawdopodobieństwo, że otrzymana struktura sieci promieniowej jest strukturą optymalną w sensie przyjętej funkcji celu. W artykule przedstawiono przykład obliczeniowy ilustrujący zastosowanie programu komputerowego do optymalizacji struktury sieci promieniowej. Uzyskane wyniki porównano z rozwiązaniem otrzymanym w wyniku przeglądu zupełnego.
EN
In the paper, the problem of the optimal design of the structures of two-voltage electric power radial networks is analyzed. The optimization of the structure of electric power networks is an NP-hard problem. The aim function of the analyzed problem is the annual cost of the electric power network structure (the annual investment cost + the annual variable cost). In order to find (suboptimal) solutions to the problem a method using genetic algorithms and simulated annealing is proposed. Both algorithms optimize (minimize) the same function. Obtaining the same solution with the use of two different algorithms increases the probability that the resulting network structure is optimal given the aim function. The paper includes also an example, which illustrates the application of the proposed method (implemented in a computer program) to the optimization of the structure of a radial network. A comparison of the obtained results with the solution resulting from the use of a complete (i.e., non-heuristic) method, is also provided.
PL
Przesył mocy biernej w sieci elektroenergetycznej jest niezbędny do funkcjonowania urządzeń zasilanych napięciem przemiennym jednak wpływa on niekorzystne na parametry jej pracy. Jednym ze sposobów ograniczenia tego wpływu jest instalacja urządzeń do kompensacji mocy biernej. Moc tych urządzeń ustalana jest najczęściej na podstawie obciążenia szczytowego sieci, tak aby spełnione zostały wymagania w zakresie dyrektywnego współczynnika mocy tg. Często moc takich źródeł mocy biernej jest stała, z zatem nie jest dostosowywana do zmian obciążenia sieci. W dolinie obciążenia przy braku tzw. kompensacji nadążnej może wystąpić problem przekompensowania co wpływa na poziomy napięć sieci zasilających. W artykule przedstawia się wybrane problemy kompensacji mocy biernej w sieci dystrybucyjnej. Przedstawiono przykłady i wyniki analiz ilustrujące wpływ sposobu kompensacji mocy biernej w sieci rozdzielczej na warunki pracy sieci elektroenergetycznej.
EN
In the paper, the selected problems of reactive power compensation in a distribution network are presented. Reactive power is indispensable for a proper functioning of alternating current devices. The negative influence of the transfer of reactive power on the working of an electric power system makes the electric power operators to reduce its consumption by determining the required value of the directive power factor in the consumer’s network. In order to meet the value of the directive factor, the consumers compensate the reactive power. If they decide to use the reactive power compensator for peak loads, it is likely that overcompensation will take place at low loads. In such cases, the load becomes a receiver of the reactive power. Such a load results in the increased voltage at the connection point even above the admissible levels. In the paper, the influence of the direction of change in the reactive power flow on the levels of voltage in an electric power system is analyzed.
PL
Złożoność projektowania struktur przemysłowych sieci elektroenergetycznych warunkują ograniczenia techniczne i ekonomiczne. Wzrost efektywności działań projektantów (zautomatyzowanie i skrócenie czasu projektowania) oraz eksploatacji projektowanej sieci można uzyskać dzięki zastosowaniu dedykowanego oprogramowania. W referacie zostanie przedstawione wykorzystanie programów stosujących algorytmy heurystyczne oraz programowanie dynamiczne do suboptymalnego projektowania struktury elektroenergetycznej sieci promieniowej zakładu przemysłowego z kompensacją mocy biernej. Optymalizowaną funkcją celu jest koszt roczny sieci rozumiany jako suma kosztów: stałego i zmiennego elementów sieci.
EN
The complexity of the designing of structures of industrial power networks is determined by following constraints: technical and economical. Increased effectiveness of: 1) designers (through shortening the design time) and 2) the operation of the proposed network (through minimizing its annual cost) can be obtained by usage of dedicated software. The paper presented the usage of heuristic algorithms and dynamic programming in designing the suboptimal structure of industrial radial power network with reactive power compensation. Optimized objective function is the annual cost of network KR understood as the sum of costs: fixed KS and variable KZ for all elements of the network.
PL
W artykule przedstawiono nowy sposób walcowania poprzecznego półwyrobów typu kula. Wykorzystuje się w nim szczęki płaskie, mające specjalnie ukształtowane występy, które działając na materiał, kształtują jednoczenie kilka kul. W celu sprawdzenia poprawności przyjętego rozwiązania wykonano obliczenia numeryczne (oparte na MES), w których wyznaczono rozkłady intensywności odkształcenia, temperatury metalu oraz składowe sił kształtowania. Opracowany proces walcowania wdrożono w Górniczej Fabryce Narzędzi w Radzyniu Podlaskim do wytwarzania półwyrobów kul, stosowanych na mielniki do młynów kulowych.
EN
This paper presents a new method of cross rolling of semi-finished products of ball type. Flat jaws with specially formed bosses, which act on material and form several balls at the same time, were used in this method. In order to verify the correctness of the assumed solutions numerical calculations were performed (basing on FEM), in which distributions of effective strain, metal temperature and forming forces constituents were determined. The worked out process was implemented in Tools Mining Factory in Radzyń Podlaski for manufacturing of semi-finished products of ball type, applied for grinding mediums in ball mills.
PL
Elektroenergetyczne sieci rozdzielcze średniego napięcia (SN) mają struktury otwarte lub zamknięte przy czym zawsze pracują w konfiguracjach otwartych. W torach głównych sieci SN instalowane są zazwyczaj łączniki umożliwiające, w przypadku awarii, separację uszkodzonego odcinka sieci. W artykule przedstawia się sposób określenia najlepszych lokalizacji łączników w sieci rozdzielczej. Przyjętym kryterium wyboru miejsca lokalizacji jest zdefiniowany współczynnik rezerwowania sieci. Do rozwiązania zadania optymalizacyjnego zastosowano algorytm ewolucyjny. W artykule przedstawiono algorytm oraz przykład obliczeniowy ilustrujący, na wycinku rzeczywistej sieci elektroenergetycznej średniego napięcia, zastosowanie opracowanego programu komputerowego.
EN
Medium voltage distribution networks have open or closed structures, but they always work in open configurations. In the distribution feeders there are installed sectionalizing switches which enable, in case of a breakdown, to separate the damaged fragment of the network. In the paper, a method for determining the optimal locations of switches in a distribution network is presented. The assumed criterion of localization is the reserve coefficient of the network. The optimization task is solved through the utilization of an evolutionary algorithm. In the paper, an executable algorithm as well as an example of an existing medium voltage distribution network are provided to illustrate the application of the developed computer program.
PL
W artykule przedstawiono metodę optymalizacji projektowania struktur dwunapięciowych elektroenergetycznych sieci promieniowych. Metoda wykorzystuje algorytm genetyczny (AG) i algorytm symulowanego wyżarzania (SW). Oba algorytmy optymalizują tą samą funkcję celu. Funkcję celu stanowi koszt roczny sieci elektroenergetycznej, który na etapie działania algorytmów jest minimalizowany. Działanie każdego algorytmu z osobna generuje, w czasie możliwym do przejęcia, suboptymalną strukturę sieci. Uzyskanie takich samych rozwiązań dwoma algorytmami zwiększa prawdopodobieństwo, że otrzymana struktura sieci promieniowej jest strukturą optymalną w sensie przyjętej funkcji celu. W metodzie algorytmy wykorzystują przemiennie, jako dane wejściowe, najlepsze uzyskane rozwiązania struktur sieci. W artykule przedstawiono krótki opis algorytmów oraz przykład obliczeniowy ilustrujący zastosowanie opracowanej metody do optymalizacji modelowej struktury elektroenergetycznej sieci promieniowej.
EN
In the paper the method for optimizing the design process of the structures of two-voltage electric power radial networks is presented. The method takes advantage of a genetic algorithm (GA) as well as a simulated annealing algorithm (SA). Both algorithms minimize the same aim function, which is the annual cost of the electric power network. The execution of each of the algorithms generates - within the same acceptable period of time - a suboptimal structure of the network. If the same result is obtained through the utilization of both methods, the probability increases that the obtained network structure is optimal against the accepted aim function. The implemented algorithms use interchangeably - as the input data - the best obtained network structures. In the paper there is also presented an example illustrating the application of the developed computer program to the optimization of a model structure of an electric power radial network.
EN
Urban medium voltage (MV) electric power distribution networks are supplied with primary (HV/MV) substations. These networks supply secondary (MV/LV) transformer substations and are often built as closed structures - loop arrangements. The design problem of optimal urban MV distribution network structure consists of determining the number of primary substations, establishing the number of MV loops supplied with the primary substations, and assigning the secondary MV/LV transformer substations to the MV loops. The optimization task becomes especially complex when the number of the primary substations is greater than one. The minimum of total annual costs is sought. The total annual costs include: fixed (investment) costs, variable (operating) costs and supply-interruption costs. Typical constraints are also accounted for. The so defined optimization problem is a complicated mathematical problem in respect of computational effort. In order to resolve the mathematical model of the optimization problem, evolutionary algorithms and artificial neural networks have been used. Exemplary computational experiments have been executed on the model of urban MV multi-loop electric power distribution networks. The results from the evolutionary algorithm and the artificial neural network calculations have been compared.
PL
Stacje transformatorowe średniego napięcia na niskie napięcie (SN/nn) spełniają podobną rolę w sieciach niskiego napięcia jak główne punkty zasilania (GPZ) w sieci średniego napięcia. Budowa nowej stacji transformatorowej SN/nn zmienia warunki pracy elektroenergetycznej sieci rozdzielczej na danym terenie poprzez: . zmniejszenie długości ciągów sieci dystrybucyjnej nn, . zmiany w rozpływie prądów, . zmniejszenie spadków napięcia, . zmniejszenie strat mocy i energii w istniejącym układzie, . zwiększenie pewności zasilania. W referacie przedstawiono wyniki obliczeń strat mocy i energii dla różnych stanów pracy sieci dystrybucyjnej niskiego napięcia. Do analizy strat mocy i energii w sieci rozdzielczej nn zastosowano model liniowy sieci. Praca stanowi kontynuację tematu zawartego w pracy [1].
EN
In the paper there are presented selected methods of minimizing power and energy loss in low-voltage networks feeding rural and suburban areas. The analysis is carried out with the use of a linear model of the network with a uniform power load along the network tracks. In order to decrease the energy loss (per one recipient) in a network with linear load (Fig. 2) one should avoid the feeding of too small a number of loads from one MV/LV transformer station (the number of connected loads should exceed 18-22). The calculations have shown that the construction of an additional feeding point usually leads to the decrease of the power and energy loss.
PL
Wprowadzenie dodatkowego źródła mocy czynnej (generacji rozproszonej GR) do układu zasilania elektroenergetycznej sieci średniego napięcia zmienia jej stan pracy. Praca dodatkowych źródeł mocy czynnej GR również wpływa na straty mocy i energii w sieci, przy czym końcowy efekt, w postaci zmniejszenia lub zwiększenia strat, zależy od mocy źródła i miejsca jego lokalizacji w sieci elektroenergetycznej.
EN
The addition of an active power source (of dispersed generation) to a medium voltage electric power network changes the state of its operation. In the paper, the influence of dispersed generation on the active power loss in distribution network is analyzed. The results show that the changes of active power loss in an electric power network with dispersed generation depend on the source's load and its location within the network.
PL
Wprowadzenie dodatkowego źródła mocy do układu zasilania elektroenergetycznej sieci średniego napięcia zmienia jej stan pracy. Efekt zmian zależy od lokalizacji w sieci dodatkowego źródła mocy oraz stopnia obciążenia sieci. W prezentowanej pracy przedstawia się badania wpływu dodatkowych źródeł mocy na pracę sieci dystrybucyjnej. Stopień obciążenia sieci elektroenergetycznej dobrano na postawie typowego uporządkowanego wykresu obciążenia Głównego Punktu Zasilania (GPZ).
EN
The introduction of an additional power source into the supplying system of an electric power medium voltage network alters its work conditions. The effect depends on the location of the additional source in the networks structure as well as the level of the network’s load. In the presented paper there are presented research results concerning the influence of an additional power source distribution on network conditions. The load level of the electric power network was determined on the basis of a typical ordered diagram of the load of a Main Feeding Point.
PL
W artykule przedstawia się zastosowanie dedykowanych programów komputerowych do obliczeń rozpływów mocy w systemach elektroenergetycznych. Ze względu na rozmiar zadania oraz nieliniowość równań opisujących zależności na moce węzłowe, do rozwiązania rozpływów mocy wykorzystuje się iteracyjne metody rozwiązywania układów równań nieliniowych. Wynikiem analizy jest wektor napięć węzłowych umożliwiający obliczenie parametrów analizowanej sieci. Lokalizowanie w elektroenergetycznej sieci rozdzielczej rozproszonych źródeł mocy powoduje konieczność obliczeń rozpływów mocy również w tej sieci. W pracy przedstawia się wyniki obliczeń rozpływów mocy fragmentu systemu elektroenergetycznego oraz sieci rozdzielczej, w której zainstalowano rozproszone źródło mocy. Przeprowadzone badania wykazały przydatność dedykowanych programów komputerowych do analizy rozpływów mocy.
EN
In the paper the application of dedicated computer programs for the calculation of the load flow in electric power systems is presented. Due to the size of the task as well as non-linearity of the equations describing the dependences of the nod-powers, the load flows are calculated with the use of an iteration-method of solving non-linear equations. The result o the calculations is a vector of no-loads enabling the computation of the parameters of the analyzed system. The installation of dispersed power sources in electric power distribution networks causes the necessity of calculating load flows also in i networks. The paper contains some results of computations of the load flows for a fragment of a power electric system and a distribution network in which there is installed a dispersed power source. The analyses show the usefulness of the dedicated computer programs for analyzing the load flow.
PL
Elektroenergetyczne sieci rozdzielcze stanowią ważne ogniwo systemu elektroenergetycznego. Optymalne projektowanie i efektywna eksploatacja tych sieci jest przedmiotem badań prowadzonych w wielu ośrodkach naukowych. W artykule przedstawiono wybrane problemy projektowania i eksploatacji elektroenergetycznych sieci rozdzielczych będące przedmiotem badań naukowych realizowanych w Laboratorium Sieci i Systemów Elektroenergetycznych Katedry Elektroenergetyki Akademii Górniczo-Hutniczej w Krakowie.
EN
Power distribution networks are an important element of the Electric Power System. The problems of optimal development and effective utilization of these networks is subject of works realized in many research institutes. In the paper there are presented selected results of scientific research realized in the Networks and Power Systems Laboratory of Department of Electrical Power AGH University of Science and Technology.
PL
W referacie przedstawiono metodę wykorzystującą algorytmy ewolucyjne, do rozwiązania zadania optymalizacji struktury sieci promieniowej dwunapięciowej. Podano oryginalny sposób kodowania zadania (budowę chromosomów), który zawiera informację o strukturze sieci elektroenergetycznej, zasilaniu rezerwowym (dodatkowym) odbiorów, lokalizacji i mocach kondensatorów proponowanych do kompensacji mocy biernej odbiorów.
EN
In the paper a method of optimizing structures of radial two-voltage network with the use of evolutionary algorithms is presented. The algorithm proposed uses an original way of coding the task (constructing the "chromosomes") that includes information about the structure of the electric power network, substitute feeding, as well as location and power of the capacitors used for compensation of reactive power of the loads.
PL
Źródła rozproszone przyłączone są zwykle do elektroenergetycznej sieci dystrybucyjnej. Właściciel elektrowni chce wyprowadzić energię elektryczną najkrótszą drogą do najbliższej sieci. Takie rozwiązanie nie zawsze jest możliwe do przyjęcia przez Spółkę dystrybucyjną elektroenergetycznej sieci rozdzielczej ze względu na zmianę parametrów pracy sieci jakie wprowadza dodatkowe źródło. W prezentowanej pracy analizowano straty mocy i energii w sieci rozdzielczej w zależności od mocy i miejsca lokalizacji w terenowej sieci rozdzielczej średniego napięcia dodatkowego źródła mocy.
EN
Dispersed sources of power are usually connected to an electric power distribution network. Assume that an owner of a power plant would like to connect his plant to the network by choosing the shortest way. Such a solution is not always possible from the point of view of the owner of the network because of the changes of the network's parameters caused by the addition of the new source of power. The paper aims at analyzing power and energy losses in a distribution network relative to the level of power and location of the new source of power within the network.
PL
W referacie przedstawiono zastosowanie sztucznej sieci neuronowej do optymalizacji wielopętlowej elektroenergetycznej sieci rozdzielczej. Pętlowa sieć rozdzielcza jest często stosowana w miejskich strukturach sieci rozdzielczych. Problem optymalizacji tej sieci, dla ustalonej liczby pętli, polega na odpowiednim przydziale stacji transformatorowych do określonych pętli oraz ustaleniu kolejności stacji transformatorowych w poszczególnych pętlach. Jako kryterium optymalizacji przyjęto minimum kosztów rocznych (koszt stały + koszt zmienny + koszt niedostarczonej energii). Problem projektowania struktur tych sieci jest podobny do zadania wielu komiwojażerów i należy do problemów NP trudnych. W artykule podano ogólny opis algorytmu oraz wyniki testów.
PL
W referacie przedstawiono problem rozbudowy elektroenergetycznej pętlowej sieci rozdzielczej. Nowe stacje transformatorowe włącz się do sieci poprzez budowę odcinków sieci w istniejących pętlach lub budowę nowych pętli. Rozbudowana sieć ma spełniać określone wymagania techniczne. Kryterium optymalizacji stanowi funkcja kosztów rocznych (koszt stały + koszt zmienny + koszt niedostarczonej energii). W referacie podano uproszczony algorytm rozwiązania problemu z wykorzystaniem Sztucznych Sieci Neuronowych (SSN) oraz przykład obliczeń wykonanych na modelach elektroenergetycznych pętlowych sieci rozdzielczych.
EN
The problem of enlargement of electric power loops distribution network is presented in the paper. New transformer are added to the network by creating new sectors of an existing network loops or by building new loops. The enlarged network should fulfill all given technical specifications. As the optimization criterion annual costs function was chosen (i.e. fixed cost + variable cost + cost of undelivered energy). The shortened version of the problem - solving algorithm using Artificial Neural Networks is given in the paper. Some results of tests performed on electric power network models are given too.
first rewind previous Strona / 1 next fast forward last