Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 15

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Optical tomograph with fixed geometry was designed and build. The tomograph was used for mesaurements of phantoms. Experimental data was used for reconstruction algorithms testing.
3
Content available remote Methods of microarray data preprocessing for classification of tumors
EN
Gene arrays measure expression levels for thousands of genes simultaneously, providing a powerful tool for both basic research and clinical medicine. The aim of this paper was to present an optimal approach to preprocessing data from cancer microarray studies. The performance of different statistical methods used for the tumor classification was also compared. These methods include: the Bayes classifier, Fisher's classifier, minimum Euclidean and Mahalanobis distance classifiers and K-nearest neighbours classifier. The preprocessing algorithms and classification methods were applied to three datasets used for diagnosis of lymphoma, leukemia and lung cancer.
4
Content available remote Fixed geometry optical scanner for laboratory use
EN
A research stand of diffuse optical tomography consisting of a developed laboratory optical scanner with fixed geometry and a PC computer was constructed. The analysis of usefulness of particular groups of image sensors (photodiodes p-n, photodiodes p-i-n, photomultipliers, CCD matrices and CIS matrices) and light sources (for visible and near-infrared light) for diffuse optical tomography was carried out. Optimization of the reconstruction process was performed. A number of software tools for simulation of the light propagation in tissue was developed. The innovative method, combining advantages of nodal and Monte Carlo methods, was proposed.
5
Content available remote Comparison of T-wave alternans detection methods
EN
T-wave alternans (TWA), which has recently been detected at the micro-volt level, is a non-invasive marker of the vulnerability to ventricular arrhythmia. The aim of this study was to compare the presently used TWA detection methods and to determine the ECG signal acquisition and processing conditions ensuring the TWA detection at its lowest possible level. The results of the evaluation and comparison of seven methods are presented. The ECG signal analysis was performed in the time and frequency domain. The differential and correlation methods were applied as the time domain methods. The complex demodulation method and methods based on the FFT and Karhunen-Loeve transform were tested as the frequency domain methods. The T-wave alternans markers were measured in 28 patients, and the results were compared. The usefulness of TWA detection methods has been demonstrated to dependant on the signal properties, such as the nonstationarity of TWA and the level of noise. Strong correlation between the magnitude of the T-wave alternans and ventricular repolarization time is described. A new, spectral methods is proposed.
PL
Przeprowadzono badania nad optymalnym doborem luminescencyjnych sensorów obrazu do systemów radiografii medycznej. Jako kryterium optymalizacji przyjęto uzyskanie maksymalnego stosunku sygnału do szumu w obrazie, scharakteryzowanego przez kwantową wydajność detekcji sensora (DQE). Sformułowano model fizyczny zjawisk zachodzących w luminescencyjnych sensorach obrazu. Opracowany model wykorzystano do obliczeń i symulacji parametrów sensorów (DQE i funkcji przenoszenia modulacji MTF) metodą Monte - Carlo oraz określenia ich optymalnych struktur.
EN
Investigation of the optimal selection of luminescent image sensors for medical radiographic systems. The main criterion of the optimization was obtaining the maximal signal - to - noise ratio in the image, characterized by the sensor detective quantum efficiency (DQE). The physical model of phenomena proceeding in luminescent image sensors was developed. The model was used to compute and simulate the sensor parameters (DQE and modulation transfer function MTF) by means of Monte - Carlo methods and to determine optimal structures.
EN
DQE (detective quantum efficiency) and MTF (modulation transfer function) of a few radiographic luminescent sensors were calculated according to the simple analytical model (originally developed by Swank and reformulated by the authors). Next, these parameters were determined using the specialized Monte Carlo simulation program and compared with analytical results. The discrepancies were discussed, and constructive conclusions for more sophisticated analytical models were formulated.
8
Content available remote Elektronika odczytu komór słomkowych w eksperymencie COMPASS
PL
W artykule przedstawiono kompleks problemów związanych z projektowaniem i budową komór słomkowych oraz współpracuiących z nimi elektronicznych układów odczytu i rejestracji danych. Przedstawiono rozwiązania stworzone na użytek eksperymentu COMPASS (CERN), w którym komory słomkowe pełnią rolę tzw. wielkopowierzchniowego detektora śladowego (Large Area Tracker), stanowiącego wraz z magnesem i detektorem Czerenkowa (RICH) pierwszy na drodze wiązki szerokokątny spektrometr cząstek. Główny nacisk położono na problemy zawiązane z uzyskaniem dużej odporności komory słomkowej na zakłócenia, niezbędnej dla uzyskania wysokiej pozycyjnej zdolności rozdzielczej.
EN
A set of problems related to design and construction of the straw chambers, their read-out electronics and data acquisition system is presented. Some solutions applied in the COMPASS experiment are shown. Straw chambers, together with a bending magnet and Cherenkov detector, are the main components of the Large Area Tracker in this experiment. Low noise and high EMI immunity of the system in terms of achieved spatial resolution is the main topic of the article.
PL
Opracowano metodykę i aparaturę do przesiewowych badań gęstości składowej mineralnej kości w diagnostyce osteoporozy. Skonstruowany skaner z głowicą scyntylacyjną może współpracować z dowolnym diagnostycznym aparatem rtg. Zoptymalizowano konstrukcję skanera i warunki pomiarów gęstości kości przedramienia, przyjmując jako główne kryterium minimalizację błędu losowego pomiaru przy ustalonej dawce promieniowania. Podano wyniki pomiarów parametrów skanera oraz przykładowe badania gęstości kości przedramienia.
EN
Methodology and equipment for osteoporosis screening were developed. A scanning system with a line, phosphor image detector for the diagnosis of osteoporosis was constructed. It can work with any diagnostic X-ray unit. The optimization of the scanning system with a scintillating head was carried out. The minimalization of the radiation dose with fixed precision was the main criterion for the optimization. The results of the scanning system parameter measurements and examples of bone density measurements are presented.
PL
W artykule sformułowano równania na kwantową wydajność detekcji promieniowania DQE i funkcje przenoszenia modulacji MTF luminescencyjnych sensorów obrazów radiograficznych, przy uwzględnieniu rozkładu absorpcji promieniowania rtg i dyfuzji promieniowania świetlnego w sensorze. Podstawą do wyprowadzenia równań była analiza zjawisk fizycznych wystepujących w sensorach. Równania wiążą zależności DQE i MTF od energii promieniowania rtg i masy powierzchniowej sensora z wielkościami opisującymi zjawiska fizyczne występujące w sensorze. Mogą być one przydatne do optymalnego doboru sensora do poszczególnych zastosowań w radiografii.
EN
Equations for DQE (Detective Quantum Efficiency) and MTF (Modulation Transfer Function) for luminescent radiographic sensor were formulated. The X-ray attenuation distribution and light diffusion, due to the physical processes in phosphors, were taken into consideration. The equations show DQE and MTF dependence on X-ray energy and phosphor surface mass which may be a useful sensor optimisation in radiographic applications.
EN
Two algorithms based on the Ordinary (OSVD) and Quotient (QSVD) Singular Value Decomposition method were developed for internal noise suppresion in 12-lead electrocardiograms. Measured signal samples are considered as vector sets in the multi-dimensional data space. Both algorithms are based on the data space transformation into the space oriented towards the direction of maximum energy or maximum signal-to-noise ratio and selective filtering of the signal components in transformed space. This allows the achievement of substantial noise reduction without significant ECG signal distortion.
PL
W pracy przedstawiono dwa algorytmy redukcji zakłóceń wewnętrznych w 12-odprowadzeniowej rejestracji elektrokardiograficznej, oparte na metodach rozkładu macierzy wzgledem wartości osobliwych: OSVD (ang.: Ordinary Singular Value Decomposition) i QSVD (ang.: Quotient SVD). Próbki mierzonych przebiegów traktowane są jako zespoły wektorów w wielowymiarowej przestrzeni danych. Obydwa algorytmy oparte są na przekształceniach przestrzeni danych w przestrzeń o osiach zorientowanych według maksymalnej energii sygnału lub maksymalnego stosunku sygnału do zakłóceń, a następnie selektywnej filtracji składowych sygnałów w przestrzeni przekształconej. Technika taka pozwala na uzyskanie znacznej redukcji poziomu zakłóceń bez znaczących zniekształceń przebiegów EKG.
12
Content available remote Monte Carlo modelling of radiographic luminescent receptors
EN
Application of luminescent receptors in medical imaging radiographic systems requires optimisation of two fundamental parameters: detective quantum efficiency (DQE) and modulation transfer function (MTF). The processes involved in radiographic image creation are so sophisticated that analytical models are oni y approximation. These processes - X-ray and light interactions with phosphor (receptor material) may be modelled by Monte Carlo method. The DQE and MTF dependence on X-ray energy and phosphor surface mass was investigated by simulation for selected phosphors.
PL
Zastosowanie sensorów luminescencyjnych w radiograficznych systemach obrazujących wymaga optymalizacji dwóch podstawowych parametrów: kwantowej wydajności detekcji (ang. DQE) i funkcji przenoszenia kontrastu (ang. MTF). Procesy tworzące obraz radiograficzny są na tyle skomplikowane, że ich modele analityczne są jedynie przybliżeniem. Dokładne modelowanie oddziaływań promieniowania jonizującego i światła z luminoforem może być przeprowadzone przy pomocy metod symulacyjnych. W pracy zbadano, z wykorzystaniem metody Monte Carlo, zależność DQE i MTF od energii promieniowania jonizującego i masy powierzchniowej sensora dla wybranych luminoforów.
PL
W artykule przedstawiono działania w kierunku restrukturyzacji technicznej i organizacyjnej kopalni, wynikające m.in. z biznes planu Katowickiego Holdingu Węglowego SA. Do codziennej praktyki wdrożono szereg przedsięwzięć technicznych, poprawiających efektywność gospodarczą, zarówno na dole kopalni ukierunkowanych na uruchamianiu ścian o zwiększonej koncentracji wydobycia i zmniejszaniu liczby ścian czynnych, jak i na powierzchni, między innymi w zakładzie mechanicznej przeróbki węgla. W artykule przedstawiono również informacje na temat postępu prac uwłaszczeniowych i zagospodarowania majątku nieprodukcyjnego.
EN
The article presents the activity towards technical and organisational restructuring of the mine resulting, among others, from business plan of Katowice Holding Coal Company. Number of technical ventures have been introduced to every day practice improving economic effcctiveness both underground directed for opening of longwalls with inercased production concentration and reduction of active longwall faces and on surface in coal preparation plant. The article also presents information on the advance in ownership changes works and management of non-production assets.
14
Content available remote Digital radiographic photodensitometry in diagnostics of osteoporosis
EN
The diagnosis of bone diseases requires bone mineral density measurement. The oldest and the simplest method of bone density screening is radiographic photodensitometry. The introduction of new digital methods of processing and correcting radiographic images creates a new outlook for this technique. The results of research on the bone density measurement system using digitized radiographs are presented in this paper. The system described is cheap ta set up, accessible for small health care centres as equipment for screening.
PL
Diagnostyka chorób kości wymaga pomiarów gęstości składowej mineralnej kości. Najstarszą i najprostszą metodą przesiewowych badań. gęstości kości jest fotodensytometria radiograficzna. Wprowadzenie nowych cyfrowych metod przetwarzania i korekcji obrazów radiograficznych stwarza nowe perspektywy dla tej techniki. W artykule zaprezentowano wyniki badań systemu do pomiaru gęstości kości wykorzystującego zdigitalizowane obrazy Rtg. Opisany system jest niedrogi i dostępny dla małych ośrodków opieki zdrowotnej jako sprzęt do badań przesiewowych.
EN
The CCSR (coherent to Compton scattering ratio) method was introduced by Puumalainen to measure bone mineral density in 1976. This method requires a spectrometric detector with good energy resolution - in practice a liquid nitrogen-cooled semiconductor Ge detector. This condition is the main reason for the rather limited clinical applications of the CCSR method. New horizons for CCSR method have been created by commercially available CdZnTe semiconductor detectors cooled by Peltier junctions. A CdZnTe detector made by Amptek Inc. (model XR-I00-CZT) has been used for bone density measurement with specially designed apparatus. Brief results of the optimization, phantom and patient measurements are presented.
PL
Spektroskopowa metoda rozproszeniowa (ang. coherent to Compton scattering ratio CCSR) została wprowadzona przez Puumalainena do pomiarów gęstości składowej mineralnej kości w 1976 r. Metoda ta wymaga zastosowania spektrometrycznego detektora o dobrej energetycznej zdolności rozdzielczej - w praktyce półprzewodnikowego detektora germanowego chłodzonego w ciekłym azocie. Warunek ten stanowi istotną barierę w aplikacjach klinicznych spektroskopowej metody rozproszeniowej. Nowe możliwości użycia tej metody powstały w związku z dostępnością detektorów półprzewodnikowych CdZnTe chłodzonych złączem Peltiera. Detektor z tellurku kadmu wyprodukowany przez firmę Amptek Inc. (model XR-100-CZT) zastosowano w analizatorze do pomiaru gęstości kości. Przedstawiono wyniki optymalizacji oraz wyniki pomiarów fantomów i pacjentów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.