Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The aim of the present study is to compare dose distributions and their verification in target areas and organs at risk (OAR) in conformal and volumetric modulated arc therapy (VMAT) techniques. Proper verification procedures allow the removal of the major sources of errors, such as incorrect application of a planning system, its insufficient or cursory commissioning, as well as an erroneous interpretation of the obtained results. Three target areas (head and neck, chest, and pelvic) were selected and the treatment was delivered based on plans made using collapsed cone convolution and Monte Carlo algorithms with 6-MV photon beams, adopting conformal and VMAT techniques, respectively. All the plans were prepared for the anthropomorphic phantom. Dose measurements were performed with TL detectors made of LiF phosphor doped with magnesium and titanium (LiF:Mg,Ti). This paper presents the results of TL measurements and calculated doses, as well as their deviations from the treatment planning system (TPS) in the three planned target areas. It was established that the algorithms subject to analysis differ, particularly in dose calculations for highly inhomogeneous regions (OAR). Aside from the need to achieve the dose intended for the tumour, the choice of irradiation technique in teleradiotherapy should be dictated by the degree of exposure toindividual critical organs during irradiation. While nothing deviated beyond the bounds of what is acceptable by international regulatory bodies in plans from TPS, clinically one must be more cautious with the OAR areas.
EN
Photon beams with wide energy ranges from 4 MV to 25 MV are commonly used in radiotherapy nowadays. In recent years, there has been a strong interest in a certain modification of a radiotherapeutic apparatus by the application of the so-called flattening filter-free (FFF) beam. Several advantages of FFF beams over standard flattening filter (FF) beams are noticed, and this technical solution has aroused great interest among radiotherapeutic facilities. The goal of the present study is to investigate the differences between the conventional FF and unflattened FFF 6-MV and 10-MV photon beams in some basic dosimetric parameters and their influence on the whole radiotherapeutic treatment. The data provided here include the detailed characteristics as follows: percent depth dose (PDD), beam profile, edge of a half-profile, total scatter correction factor (TSCF) and head scatter correction factor (HSCF) for FF and FFF 6-MV and 10-MV photon beams from the Elekta Versa HD accelerator in the Katowice Oncology Center in Poland.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.