The objective of this paper is an experimental study of the most crucial parameters of the received acoustic signals (e.g. signal-to-noise ratio (SNR), side-lobes level (SLL), axial resolution) obtained as a result of simultaneous emission of mutually orthogonal Golay complementary sequences (MOGCS) to demonstrate their feasibility of being used in ultrasound diagnostics. Application of the MOGCS in ultrasound measurements allows the image reconstruction time to be shortened without decreasing the resulting quality of reconstructed images in comparison with regular complementary Golay coded sequences (CGCS). In this paper two sets of 16-bits long MOGCS were implemented in the Verasonics Vantage™ (Verasonics Inc., Kirkland, WA, USA) scanner. Ultrasound data were generated using a perfect reflector, a custom-made nylon wire phantom and tissue mimicking phantom. Parameters of the detected MOGCS echoes like SNR, SLL and axial resolution were determined and compared to that of the standard CGCS and the short two-sine cycles pulse. It was evidenced that applying MOGCS did not compromise the parameters of the separated and compressed echoes in comparison to the other types of transmitted signal – the CGCS and the short pulse. Concretely, both the MOGCS and CGCS yield similar SNR increase in comparison to the short pulse. Almost similar values of the axial resolution estimated at the full width at the half maximum level for all types of the transmitted signals were also obtained. At the same time, using the MOGCS the data acquisition speed can be increased twice in comparison with the CGCS signal.
EN
Acoustical Driving Forces (ADF), induced by propagating waves in a homogeneous and inhomogeneous lossy fluid (suspension), are determined and compared depending on the concentration of suspended particles. Using integral equations of the scattering theory, the single particle (inclusion) ADF was calculated as the integral of the flux of the momentum density tensor components over the heterogeneity surface. The possibility of negative ADF was indicated. Originally derived, the total ADF acting on inclusions only, stochastically distributed in ambient fluid, was determined as a function of its concentration. The formula for the relative increase in ADF, resulting from increased concentration was derived. Numerical ADF calculations are presented. In experiments the streaming velocities in a blood-mimicking starch suspension (2 μm radius) in water and Bracco BR14 contrast agent (SF6 gas capsules, 1 μm radius) were measured as the function of different inclusions concentration. The source of the streaming and ADF was a plane 2 mm diameter 20 MHz ultrasonic transducer. Velocity was estimated from the averaged Doppler spectrum obtained from originally developed pulsed Doppler flowmeter. Numerical calculations of the theoretically derived formula showed very good agreement with the experimental results.
EN
The computing performance optimization of the Short-Lag Spatial Coherence (SLSC) method applied to ultrasound data processing is presented. The method is based on the theory that signals from adjacent receivers are correlated, drawing on a simplified conclusion of the van Cittert-Zernike theorem. It has been proven that it can be successfully used in ultrasound data reconstruction with despeckling. Former works have shown that the SLSC method in its original form has two main drawbacks: time-consuming processing and low contrast in the area near the transceivers. In this study, we introduce a method that allows to overcome both of these drawbacks. The presented approach removes the dependency on distance (the “lag” parameter value) between signals used to calculate correlations. The approach has been tested by comparing results obtained with the original SLSC algorithm on data acquired from tissue phantoms. The modified method proposed here leads to constant complexity, thus execution time is independent of the lag parameter value, instead of the linear complexity. The presented approach increases computation speed over 10 times in comparison to the base SLSC algorithm for a typical lag parameter value. The approach also improves the output image quality in shallow areas and does not decrease quality in deeper areas.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.