Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
Niniejszy artykuł prezentuje możliwość wykorzystania protokołu DNS do utworzenia jednostronnego kanału komunikacyjnego pomiędzy komputerem zainfekowanym złośliwym oprogramowaniem, a skompromitowanym serwerem DNS. Kanał taki może posłużyć do niepostrzeżonej kradzieży danych użytkownika, bądź poufnych informacji firmowych.
EN
This paper presents possibility of using of the DNS protocol for creating a simplex communication channel between a malware infected computer with malware and a compromised DNS server. The proposed channel can be used to steal data or confidential enterprise information secretly.
2
Content available Network Steganography in the DNS Protocol
EN
This paper presents possibility of using of the DNS (Domain Name System) protocol for creating a simplex communication channel between a malware-infected computer with a compromised DNS server. The proposed channel can be used to steal data or confidential enterprise information secretly.
3
Content available remote Chlorowce w wodach powierzchniowych zlewni górnej Odry
PL
W pracy dokonano analizy zmian zawartości chlorowców (Cl-, Br-i I-) w wodach powierzchniowych zlewni górnej Odry z uwzględnieniem ich stanów: wysoki, średni i niski. Oceniono również stan chemiczny wód powierzchniowych badanego obszaru na podstawie następujących parametrów fizykochemicznych: Cl-, PEW, mineralizacja, SO4/2-i odczyn pH. Stwierdzono, że wody zlewni górnej Odry należy sklasyfikować jako nie osiągające dobrego stanu chemicznego dla całego okresu badań, jak i trzech analizowanych stanów.
EN
This paper presents an analysis of changes in halogens (Cl, Br and I) concentration in the surface waters of Upper Odra River Basin. Three water levels were considered: high, medium and low. Moreover, water’s chemical condition was assessed, on the basis of the following physical-chemical parameters: Cl, conductivity, mineralization, SO42 and pH. As a result, the surface waters of Upper Odra River Basin were attributed with bad chemical state in the period of study and for all levels of water.
PL
Istotnym elementem monitoringu jakości wód podziemnych jest proces opróbowania wód, obejmujący nie tylko sam etap poboru próbek, ale także czynności związane z ich utrwalaniem, przechowywaniem oraz transportem do laboratorium, jak również terenowymi pomiarami wskaźników nietrwałych. Z uwagi na różnorodność możliwych sytuacji, rzeczywiste badania terenowe mogą odbiegać od przedstawianych w literaturze schematów. Wykorzystując własne wieloletnie doświadczenie, autorzy prezentują praktyczne aspekty poboru próbek wód podziemnych, podając przykłady konkretnych rozwiązań organizacyjno-technicznych. Przytoczono podstawowe dokumenty normujące proces opróbowania oraz istniejące poradniki. Omówiono potencjalne zagrożenia związane z pracą w terenie, przedstawiono zróżnicowane sposoby poboru próbek, stosowane w zależności od rodzaju punktu monitoringowego. Scharakteryzowano najczęściej wykorzystywane w monitoringu wód podziemnych rodzaje pojemników i utrwalaczy, a także pomiary parametrów fizykochemicznych wskaźników nietrwałych wykonywane in situ.
EN
The crucial element of groundwater monitoring is the properly carried out groundwater sampling, which includes not only the stage of collecting samples, but also all activities related to samples preservation, storage, transport to the laboratory and also field measurements of unstable indicators. In view of variability of possible situations, the actual field exploration may diverge from shown in literature schemes. Making use of multi-year experience, the authors present the practical aspects of groundwater sampling, giving the examples of concrete organise-technical solutions. The basic norms and guides concerning sampling were detailed. The potential dangers related to work in the field were discussed. Multiple techniques of sampling, considering sampling site type, were presented. There were characterised the most common in groundwater monitoring types of containers and preservatives and also basic measurements of unstable physic-chemical parameters performed in situ.
PL
Ramowa Dyrektywa Wodna (DRW, 2000) wymaga ustanowienia dwóch programów monitoringu wód podziemnych: stanu ilościowego i stanu chemicznego. Sieć monitoringu dla oceny stanu chemicznego wód podziemnych powinna pozwolić na przeprowadzenie oceny w każdym dorzeczu oraz wykrycie długoterminowych trendów zmian jakości wód. W niniejszym artykule zaprezentowano ocenę stanu chemicznego wód podziemnych, przeprowadzoną zgodnie ze wskazaniami RDW, dla wytypowanego obszaru – południowej części zlewni potoku Sękówka, na podstawie wyników własnych terenowych i laboratoryjnych badań monitoringowych. Wyniki badań laboratoryjnych poddano weryfikacji na podstawie błędu analizy wyliczonego według bilansu jonowego. Określono typy hydrogeochemiczne wód zgodnie z klasyfikacją Szczukariewa-Prikłońskiego. Ocenę stanu chemicznego wód podziemnych przeprowadzono w układzie punktowym i obszarowym zgodnie z wytycznymi przepisów polskich (RMŚ, 2008) i UE (RDW, 2000).
EN
Water Framework Directive (RDW, 2000) requires establishing two programmes, which should cover monitoring of the chemical and quantitative status of groundwaters. The monitoring network for the chemical status assessment of groundwaters shall be designed so as to provide a comprehensive overview of chemical status within each river basin and shall permit identification of long-term trends of variations in groundwater quality. In this paper the chemical status assessment of groundwater of the south part of Sękówka River catchment area was presented, conducted in accordance with above requirements and using own field and laboratory research results. Laboratory results were verified on the base of analyses errors calculated as per the ionic balance. The hydrogeochemical types were specified in accordance with the Szczukariew-Prikłoński classification. The chemical status assessment of groundwater was conducted in point and area configuration, according to Polish (RMŚ, 2008) and UE (RDW, 2000) regulations.
PL
Zgodnie z obowiązującymi przepisami Unii Europejskiej (RDW2000; DWP 2006; DT 2009) monitoring jakości wód powierzchniowych i podziemnych powinien obejmować m.in. identyfikację wszystkich źródeł niepewności procedury analitycznej. Ponadto dyrektywa (DT 2009) oraz rozporządzenie (RMOE 2011) wskazują na konieczność prowadzenia programu zapewnienia i kontroli jakości (QA/QC) badań w monitoringu wód, a także podają wartość graniczną niepewności pomiaru szacowanej na poziomie odpowiednich norm jakości środowiska równej 50% lub mniejszej (k = 2).W rozporządzeniu (RMOE 2011) określono również metody referencyjne stosowane w monitoringu wód. W niniejszej pracy zastosowano empiryczne podejście (Nordest 2006,2007;Witczak i in. 2006; EURACHEM 2007; Kmiecik 2008; Kmiecik, Drzymała 2008; Kmiecik 2011) do oszacowania wartości niepewności całkowitej oraz jej składowych: niepewności geochemicznej, niepewności opróbowania i niepewności analitycznej. Dodatkowo zbadano wpływ metodyki poboru próbek na niepewność pomiaru. Do oceny niepewności wykorzystano wyniki analiz próbek normalnych i kontrolnych (dublowanych), pobranych w ramach monitoringu wód powierzchniowych Zlewni Górnej Odry oraz wód kopalnianych do niej odprowadzanych. Szacowanie niepewności całkowitej i jej komponentów pokazano na przykładzie wyników oznaczeń I– w próbkach normalnych i dublowanych. Określono wpływ rodzaju pojemnika na niepewność pomiaru. W tym celu zastosowano dwie procedury poboru próbek, obejmujące zastosowanie dwóch różnych pojemników na próbki. Analizę zawartości I– wykonano metodę ICP-MS w akredytowanym Laboratorium Hydrogeochemicznym. Każda z próbek poddana była dwukrotnej analizie. Do oszacowania wartości niepewności całkowitej i jej składowych zastosowano program ROBAN.
EN
According to European Union present legal state (RDW2000; DWP 2006; DT 2009) surface and ground water quality monitoring should also include identification of all uncertainty associated with analytical procedure sources. Moreover, directives (DT 2009; RMOE 2011) indicate necessity of implementation the quality assurance and quality control program(QA/QC) of research in water monitoring. They also give the measurement uncertainty threshold value assesst basing on adequate norms of environment quality and is equal to 50% or less (k=2). In directive (RMŚ 2011) there are also defined reference methods, which should be use in water monitoring. In this paper the empirical approach for total uncertainty and its components (geochemical, sampling and analytical) assessment was used (Nordest 2006, 2007; Witczak et al. 2006; EURACHEM 2007; Kmiecik 2008; Kmiecik, Drzymała 2008; Kmiecik 2011). Moreover, the influence of sampling method on the measurement uncertainty was examined. For uncertainty estimation there were used results from analyses of normal and control (duplicate) samples, which were collected within monitoring of Upper Odra River Basin surface water and coalmine water inducted to it. The assessment of total uncertainty and its components was shown on the example of I- results delivered from normal and duplicate samples analyses. The influence of container type on measurement uncertainty was determined. For this aim two procedures of samples collecting were used, concerning two types of samples containers. The iodide analyses was performed using ICP-MS method in accredited Hydrogeochemical Laboratory Each sample was analysed twice. For total uncertainty and its components assessment the ROBAN program was applied.
EN
In compliance with European Union present legal state (Directive 2000, 2006, 2009) surface and ground water quality monitoring should also include identification of each source of uncertainty associated with analytical procedure. Moreover, directives (Directive 2009, RMŚ 2011) indicate necessity of implementation the quality assurance and quality control program (QA/QC) of research in water monitoring. They give the measurement uncertainty threshold value as well, which is assessed basing on adequate norms of environment quality and it's equal to 50% or less (k — 2). In this paper the empirical approach for total uncertainty and its components (geochemical, sampling and analytical) assessment was used (Witczak et al. 2006, Nordtest 2007, Kmiecik 2011, Drzymała 2012). In such approach, according to Ramsey et al. (1992), the percentage contribution of measurement variance in total variance cannot exceed 20%. Otherwise, the interpretation of hydrogeochemical data cannot be performed correctly. Moreover, the influence of sampling method on the measurement uncertainty was examined. For uncertainty estimation there were used results from analyses of normal and control (duplicate) samples, which were collected within monitoring of Upper Odra River Basin surface water and coalmine water inducted to it. The assessment of total uncertainty and its components was shown on the example of Br results delivered from normal and duplicate samples analyses. The influence of container type on measurement uncertainty was determined. For this aim two procedures of samples collecting were used, concerning two types of samples containers: polyethylene containers and dark glass containers. The bromide analyses were performed using ICP-MS method in accredited Hydrogeochemical Laboratory. Each sample was analysed twice. For total uncertainty and its components assessment the ROBAN program with rANOVA technique was applied. Basing on delivered results it was stated, that in the two groups of bromide results in samples collected neither into polyethylene containers nor to dark glass containers, the measurement variance doesn't exceed the threshold value of 20% of total variance and is equal to 0.08% and 0.02% respectively. In both cases, for two types of containers, also relative uncertainty of measurement doesn't exceed the threshold value of 50% and is equal to 5.39% and 3.05% respectively. However, the difference between values of relative uncertainty of measurement is significant and indicates the necessity of collecting samples for bromide determination into dark glass containers if possible.
8
Content available remote Assessment of stability of groundwater chemical composition from Nadzieja Spring
EN
Nadzieja Spring, artesian deep well is located in confined Jurassic carbonate fissured aquifer. The well belongs to network of wells used as an emergency water supply for urban population and is open for public use. Therefore this water should be safe for health and its chemical composition should be stable in time. Since November 1998 Department of Hydrogeology and Geology Engineering (AGH University of Science and Technology) has led up monitoring of Nadzieja Spring water quality. Average interval between samplings was ca. two weeks. Samples were collected in accordance with guidelines applied in groundwater monitoring (Witczak & Adamczyk 1994, 1995) and the procedure of groundwater sampling described in norms of PN-EN 5667 series. Chemical analyses of 13 basic elements were performed at hydrogeochemical laboratory, which implements extensive quality assurance and analytical quality control programme (PN-EN ISO/IEC 17025). The goal of this study was to assess the stability of chemical composition of groundwater, which is intended for human consumption. Specific methodology has been proposed for this purpose (Ciężkowski 2007). According to Polish regulations (RMZ, 2010) the composition of water is stable, when the variation range is: x +2o. The assessment of stability was performed for components, which influence on the hydrogeochemical type of water: HCO3- and Mg +. The component influences on the hydrogeochemical type of water, when its amount in [mval] is greater than 20% (RMZ, 2006). Between November 2002 and January 2007 98 samples were collected. Detailed analysis was performed for data from 2002 to 2007. To identify and reject outliers there were used box and whisker plots. Verification of data distribution was made on the base of the results from the Kohnogorow-Smirnow Test. Due to this test it was found out, that concentrations of HCO3- are characterized by normal distribution. The concentrations of Mg + are characterized by bimodal distribution. Detailed statistic analysis, in addition with observations of methods used in laboratory for Mg2+ determination, showed that two groups of data are result of changing methodology (change ICP-OES to ICP-MS in 2004). Separately verification of both groups distribution showed, that concentrations of Mg2+ are characterized by normal distribution, what is request for control charts. Control charts (Szczepańska & Kmiecik 1998, 2005) were used to assess the stability of examined components. On the basis of this analysis the following information was derived: - the content of HCO3 and Mg2+ in water from Nadzieja Spring in Krakow is stable (most of values are in range x ± 2a); - HCO3- and Mg influence on the hydrogeochemical type of water (their content in milivals [mval] is greater than 20%); - in case of long time series, analysis should be performed in different variants concerning factors responsible for changes of chemical components.
PL
Referat opisuje założenia projektu badawczego podejmującego zagadnienie poprawy współpracy pierścieni wiodących pocisków broni granatnikowej z lufą. Omówiono wyniki badań nad możliwością wykorzystania znanych technologii nakładania warstwy stopów miedzi do wytwarzania miedzianych pierścieni wiodących na aluminiowym pocisku. W dalszej części przedstawione zostały rozwiązania proponowane w zakresie poprawy technologii wytwarzania wkładek fragmentujących, możliwe do wykorzystania zarówno w obecnie stosowanej amunicji jak i w nowo projektowanych. Ostatnim poruszonym zagadnieniem są wyniki badań nad wykorzystaniem tworzyw sztucznych do wytwarzania zarówno pierścieni wiodących jak i całych elementów amunicji granatnikowej.
EN
The paper describes assumptions of research project taking on an issue of improvement cooperation of rotating band with a barrel of a grenade launcher. Discusses the results of study on possibilities of utilizing known technologies of depositing layers of copper alloys to manufacturing rotating bands made of copper. In the following part there are presented solutions which are proposed to improve production technology of fragmentation liner. New solutions are possible to use both in new projects and in ammunition which is currently in use as well. The last issue which was describe are results of studies on possibilities of utilizing plastics for manufacturing not only rotation bands, but also full parts of grenade ammunition.
PL
Artykuł zawiera porównanie programowalnych zapalników czasowych z nową generacją zapalników programowanych poprzez zliczanie liczby obrotów na torze lotu. W części wstępnej zamieszczono omówienie zasad działania nowej generacji zapalników, a także charakterystykę konstrukcji nowych granatów. Cechą charakterystyczną nowego rozwiązania jest to, że zapalnik programowalny zapewnia detonację granatu po przebyciu założonego dystansu, określanego za pomocą liczby obrotów granatu w czasie lotu. W dalszej części przeprowadzone jest porównanie pokazujące znaczące różnice w zakresie precyzji ataku pomiędzy nowymi rozwiązaniami a rozwiązaniami klasycznych zapalników czasowych. W pracy zamieszczone są porównania torów lotu pocisków, punktów detonacji oraz wnioski końcowe.
EN
Article contains a comparison of classical time fuzes, and new generation of fuzes programmed to explode after travelling a certain distance, which is calculated by counting the number of the grenade rotations. Comparison shows large differences in field of efficacy of attack between mentioned solutions. It contains also comparison of ballistic traces, points of detonation and conclusions which were drawn.
PL
Zdrój Główny w Krzeszowicach ujmuje wody podziemne z utworów mioceńskich. Eksploatacja ujęcia prowadzona jest z przerwami od 1780 roku. Wody te wykorzystywane są wyłącznie na cele lecznictwa balneologicznego. Badania jakości wód ze Zdroju Głównego w Krzeszowicach prowadzone są przez Katedrę Hydrogeologii i Geologii Inżynierskiej AGH od 2002 roku. Próbki pobierane są w odstępach miesięcznych. Składniki chemiczne (17 składników) oznaczane są w laboratorium KHGI metodą ICP-AES (PN-EN ISO 11885:2001), natomiast H2S oznaczany jest w akredytowanym laboratorium Wojewódzkiego Inspektoratu Ochrony Środowiska w Krakowie, zgodnie z normąPN-C-04566.03:1982. W okresie od 31.01.2004 do 31.03.2008 pobrano ogółem 51 próbek. Ocenę stabilności składu chemicznego wód ze Zdroju Głównego w Krzeszowicach przeprowadzono dla trzech składników głównych, decydujących o typie hydrogeochemicznym: S04/2-, Ca2+, Mg2+ oraz składnika swoistego - siarkowodoru (H2S). Do identyfikacji obserwacji odstających zastosowano wykresy skrzynkowe. W celu weryfikacji rozkładu opisującego dane wykorzystano test Shapiro-Wilka. Ocenę stabilności oznaczeń przeprowadzono z wykorzystaniem metody kart kontrolnych (Szczepańska, Kmiecik,1998, 2005). Z przeprowadzonej analizy uzyskano następujące wnioski: stężenia głównych składników: SO4/2-, Ca2+ i Mg2+ w wodach ze Zdroju Głównego w Krzeszowicach mieszczą się w przedziale x+=2delta a zatem należy je uznać za stabilne; składniki te wpływają na typ hydrogeochemiczny wody - ich stężenia stanowią więcej niż 20% mval; stwierdzono rosnący trend wartości stężeń siarkowodoru w czasie, jednak na podstawie analizy przeprowadzonej z wykorzystaniem programu GWSTAT stwierdzono, że z prawdopodobieństwem 95% nie jest on statystycznie istotny.
EN
Zdrój Główny in Krzeszowice intakes sulfide waters from Miocene deposit. Exploitation of this intake has run since the 1780. Water from Zdrój Główny is being used only for balneological treatment. Since the 2002 Department of Hydrogeology and Geology Engineering (AGH - University of Science and Technology) has led up continuous monitoring of its water quality. Average interval between consecutive samplings was ca. one month. Samples were filtered through membrane filter (0.45 micro/m) and transported to laboratory. Chemical analyses of 17 elements were performed with ICP-AES method (PN-EN ISO 11885:2001) and H2S determination were performed in the accredited laboratory according to norm PN-C-04566.03:1982. Between January 2004 and March 2008 51 samples were collected. The assessment of stability was performed for components, which influence on the hydrogeochemical type of water: SO4/2- , Ca2+, Mg2+ and H2S (RMZ, 2006). To identify and reject outliers there were used Box-and-Whisker Plots. Verification of data distribution was made on the base of results from the Shapiro-Wilk Test. Control charts (Szczepańska, Kmiecik, 1998, 2005) were used to assess the stability of examined components. On the basis of this analysis the following information was derived: the content of SO4/2- , Ca2+ and Mg2+ in water from Zdrój Główny in Krzeszowice is stable (most of values are in range x- 2delta x+ 2delta); SO4/2-, Ca2+, Mg2+ influences on the hydrogeochemical type of water (their content is greater than 20% mval); the upward trend for H2S was detected, however detailed analysis with GWstat programme showed, that this trend is statisticaly non-significant (for 95% confidence level).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.