Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 46

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
The article presents the idea of a system enabling effective control of production processes. A high level of automation and control of production processes plays a key role in maintaining a high level of competitiveness of each enterprise. The proposed system concept consists of a network of distributed sensors that enable the measurement of many process parameters, manufacturing resources and the state of the machine park. The described control system uses both wired and wireless communication. The implemented communication systems will enable obtaining data from various sensors and other subsystems installed in enterprises, as well as obtaining data from new systems and sensors used to measure all types of processes, from production set-up to the final product. The described solution includes the use of process tomography sensors based on electrical tomography. The conducted research shows that the use of tomographic methods enables effective management of the intelligent structure of companies in the scope of manufacturing processes control.
PL
W artykule przedstawiono ideę systemu umożliwiającego efektywną kontrolę procesów produkcyjnych. Wysoki poziom automatyzacji i kontroli procesów produkcyjnych odgrywa kluczową rolę w utrzymaniu wysokiego poziomu konkurencyjności każdego przedsiębiorstwa. Proponowana koncepcja systemu składa się z sieci rozproszonych czujników, które umożliwiają pomiar wielu parametrów procesu, zasobów produkcyjnych i stanu parku maszynowego. Opisany system sterowania wykorzystuje zarówno komunikację przewodową, jak i bezprzewodową. Zaimplementowane systemy komunikacyjne umożliwią pozyskiwanie danych z różnych czujników i z innych podsystemów zainstalowanych w przedsiębiorstwach, a także uzyskiwanie danych z nowoopracowanych systemów i czujników używanych do pomiaru wszystkich typów procesów, począwszy od przygotowania produkcji aż do produktu końcowego. Opisane rozwiązanie obejmuje wykorzystanie czujników tomografii procesowej w oparciu o tomografię elektryczną. Przeprowadzone badania dowodzą, że zastosowanie metod tomograficznych umożliwia efektywne zarządzanie inteligentną strukturą firmy w zakresie sterowania procesami produkcyjnymi.
EN
The presented research presents a method of using the smallest angles regression algorithm to solve the inverse problem in electrical impedance tomography in relation to a damp wall. Highly correlated predictors in linear models make it difficult to precisely determine the influence of these predictors on the output variable. The standard application of the least-squares method to estimate unknown parameters may lead to a poor forecast. Adding a penalty parameter depending on quantities of parameters to the least square criterion allows us to determine the biased estimators but also to reduce the variance of estimators.
PL
Przedstawione badania dotyczą sposobu wykorzystania algorytmu regresji najmniejszego kąta (LARS) do rozwiązania problemu odwrotnego w elektrycznej tomografii impedancyjnej w odniesieniu do wilgotnej ściany. Wysoce skorelowane predyktory w modelach liniowych utrudniają precyzyjne określenie wpływu tych predyktorów na zmienną wyjściową. Standardowe zastosowanie metody najmniejszych kwadratów do oszacowania nieznanych parametrów może prowadzić do złej prognozy. Dodanie elementu kary w zależności od ilości parametrów do kryterium najmniejszego kwadratu pozwala nam określić estymatory obciążenia, a także zmniejszyć wariancję estymatorów.
EN
Impulse noise is particularly hazardous to the hearing of exposed individuals. In many real-life scenarios, the only protective measure used to reduce the level of impulse noise is hearing protectors. These scenarios include firing ranges. Aside from hearing protectors, shooters use personal safety spectacles. The purpose of this paper was to determine the effect of the simultaneous use of earmuffs and safety spectacles on the sound attenuation of earmuffs during exposure to impact noise. The research was completed with the MIRE method and included the determination of sound attenuation changes in five different models of earmuffs, used simultaneously with three different models of safety spectacles and prescription glasses. The impulse noise source used was a starting pistol, which generated C-weighted peak sound pressure level at a mean of 136.7 dB. The tests demonstrated that the simultaneous use of safety spectacles and earmuffs reduces the impulse noise attenuation of the earmuffs by up to 9 dB. Such sound attenuation changes occurred during simultaneous use of earmuffs with safety spectacles, which feature temples with a rectangular cross-section. The tests also demonstrated that the effect of prescription glasses on sound attenuation was unusually high; prescription glasses reduced the impulse sound attenuation of earmuffs by as much as 18 dB.
PL
Hałas impulsowy jest szczególnie niebezpieczny dla słuchu osób na niego eksponowanych. W wielu sytuacjach jedynym środkiem ograniczania hałasu impulsowego są ochronniki słuchu. Taka sytuacja występuje na przykład na strzelnicach. Poza ochronnikami słuchu strzelcy również często korzystają z indywidualnych ochron oczu. Celem przedstawionych badań było określenie jak jednoczesne stosowanie nauszników przeciwhałasowych i okularów wpływa na zmianę tłumienia nauszników w sytuacji występowania hałasu impulsowego. Badania zostały przeprowadzone z wykorzystaniem metody MIRE i obejmowały wyznaczenie zmian tłumienia dźwięku pięciu modeli nauszników przeciwhałasowych stosowanych jednocześnie z trzema modelami okularów ochronnych oraz okularami korekcyjnymi. Źródłem hałasu impulsowego był pistolet startowy, który generował dźwięk o szczytowym poziomie dźwięku C wynoszącym średnio 136,7 dB. Przeprowadzone badania wykazały, że jednoczesne używanie okularów ochronnych i nauszników obniża tłumienie hałasu impulsowego wnoszone przez nauszniki maksymalnie do 9 dB. Takie zmiany występowały podczas jednoczesnego stosowania nauszników i okularów charakteryzujących się zausznikami o prostokątnym przekroju. Badania także wykazały wyjątkowo duży wpływ okularów korekcyjnych na tłumienie nauszników, które spowodowały pogorszenie tłumienia hałasu impulsowego wnoszonego przez nauszniki nawet o 18 dB.
4
Content available remote Water demand forecasting by trend and harmonic analysis
EN
Water demand forecasting in water supply systems is one of the basic strategic management tasks of water supplying companies. This is done using specially designed water consumption models which generate data necessary for planning operational activities. A high number of water demand forecasting methods proposed in the literature points to the complexity and significance of the problem for current operation of water supplying companies. However, it must be observed that no universal method applicable to any water supply system has been developed so far. In addition to this, there is no method which could be considered referential relative to other methods. For this reason, it is necessary to continue the research on forecasting methods enabling effective forecasts based on suitably selected sets of input quantities. This paper proposes a solution for water consumption forecasting in a water supply system, wherein hourly water consumption is determined by trend analysis and harmonic analysis. Trend analysis consists in estimating parameters of models for individual phases of a cycle, while harmonic analysis is based on the assumption that a time series consists of sine and cosine waves with different frequencies known as harmonics. In addition, relationships between structural parameters of individuals harmonics and ambient temperature are investigated using the least squares method.
EN
The tests reported in this paper were carried out to evaluate the exposure of soldiers to noise at operator and control positions during military field exercises. The tests were conducted during firing from a T-72 tank, a BWP-1 Infantry Fighting Vehicle, antitank guided missiles, a ZU-23-2K anti-aircraft gun, and a 2S1 GOZDZIK howitzer. The evaluation of noise exposure showed that the limit values of sound pressure level, referred to by both Polish occupational noise protection standards and the Pfander and Dancer hearing damage risk criteria developed for military applications, were repeatedly exceeded at the tested positions. Despite of the use of tank crew headgear, the exposure limit values of sound pressure level were exceeded for the crew members of the T-72 tank, the BWP-1 infantry fighting vehicle, and the 2S1 GOZDZIK howitzer. The results show that exposure of soldiers to noise during military field exercises is a potentially high hearing risk factor.
EN
This paper reports the results of compressive strength and elasticity studies of light-cured polymer matrix ceramic composites (LC PMCCs). The main purpose was to obtain new data on experimental composites and compare them with commercial composites from the world’s leading manufacturer. The objective was to investigate the relationship between the content of reinforcing components in the composites studied and the stability of their strength in time, expressed as the number of fatigue thermal cycles.
PL
Coraz częściej smartfony stają się urządzeniami służącymi do pomiaru poziomu ciśnienia akustycznego. W pracy przeanalizowano, czy smartfony mogą być także użyte jako urządzenia wspomagające dobór ochronników słuchu. Przeprowadzono pomiary poziomu ciśnienia akustycznego w pasmach 1/3-oktawowych za pomocą trzech modeli smartfonów. W badaniach tych korzystano zarówno z wewnętrznych mikrofonów wbudowanych w smartfony, jak również z mikrofonu zewnętrznego dołączanego do smartfonów za pomocą gniazda „jack”. Otrzymane wartości poziomu ciśnienia akustycznego w pasmach 1/3-oktawowych porównano z pomiarami odniesienia przeprowadzonymi z wykorzystaniem miernika poziomu dźwięku. Porównanie to wskazuje, że występują pewne różnice pomiędzy wynikami pomiarów otrzymanych za pomocą smartfonu i miernika poziomu dźwięku. Jednakże po zastosowaniu odpowiedniej korekcji istnieje możliwość stosowania smartfonów jako urządzeń wspomagających dobór ochronników słuchu.
EN
More and more often, smartphones are used to measure sound pressure levels. The work has analyzed whether smartphones can also be used to selection of hearing protectors. Sound pressure levels in 1/3-octave bands were measured using three smartphone models. Both internal microphones built into smartphones as well as an external microphone attached to smartphones using the jack connector were used. The obtained values of the sound pressure level in the 1/3-octave bands were compared with reference measurements made using the sound level meter. This comparison indicates that there are some differences between the measurement results obtained with the smartphone and the sound level meter. However, after applying the correction, there is possible to use smartphones to selection of hearing protectors.
PL
W przypadku narażenia na hałas impulsowy istotne jest określenie, jak ochronnik słuchu wpływa na ograniczenie impulsu akustycznego, które jest wyrażane wartością tłumienia szczytowego poziomu dźwięku C. Przeprowadzono pomiary ograniczania impulsów akustycznych przez jedenaście ochronników słuchu z regulowanym tłumieniem (dziewięć nauszników i dwie wkładki przeciwhałasowe). Impulsy wytwarzano z użyciem laboratoryjnego źródła hałasu impulsowego. Wkładki przeciwhałasowe z regulowanym tłumieniem silniej ograniczają impulsy akustyczne (przeciętnie o 17 dB) niż nauszniki przeciwhałasowe z regulowanym tłumieniem. Część nauszników przeciwhałasowych z regulowanym tłumieniem może nie zapewniać dostatecznej ochrony słuchu przed impulsami akustycznymi o dużym szczytowym poziomie dźwięku C.
EN
In the case of exposure to impulse noise, it is important to determine how the hearing protector affects the reduction of acoustic impulse expressed by the attenuation of the C-weighted peak sound pressure level. The reduction of acoustic impulses were measured in the case of nine level-dependent earmuffs and two level-dependent earplugs. Impulses were generated using a laboratory source of impulse noise. Level-dependent earplugs more strongly reduce acoustic impulses (on average 17 dB) than level-dependent earmuffs. Some of the level-dependent earmuffs may not provide adequate protection against high C-weighted peak sound pressure level acoustic impulses.
PL
Analizowano parametry sygnałów docierających do użytkownika ochronników słuchu w sytuacji, gdy przebywa on w przykładowym miejscu pracy, gdzie wytwarzany jest hałas i jednocześnie istotny jest odbiór dźwiękowych sygnałów bezpieczeństwa emitowanych przez pojazdy, tj. sygnałów ostrzegających o jeździe wstecz. Analizą objęto trzy nauszniki przeciwhałasowe z regulowanym tłumieniem. Obecność hałasu w środowisku pracy sprawia, że najczęściej nie jest możliwy prawidłowy odbiór dźwiękowego sygnału bezpieczeństwa, w tym również w przypadku stosowania nauszników przeciwhałasowych z regulowanym tłumieniem.
EN
In addition to limiting noise exposure, an important aspect of the use of hearing protectors is the perception of auditory danger signals (warning signals). Proper sound reception, which affects the worker’s safety, may not be possible in the presence of noise. The parameters of the signals coming to the user of hearing protectors have been analyzed when he is in an exemplary industrial workplace where noise is generated and at the same time the reception of auditory danger signals emitted by vehicles is important i.e. backup alarms. The analysis included three models of level-dependent earmuffs. The presence of noise in the work environment makes it impossible to properly receive auditory danger signal, including the situations when level-dependent earmuffs are used.
EN
The goal of the study was to assess the manner in which the direction of an industrial truck auditory danger signal is perceived in the presence of noise. A particular element of the study was the reconstruction in the laboratory of actual workplace conditions using acoustic signals recorded in the working environment, taking into account the wearing of hearing protectors. The constructed experimental set-up is described (Fig. 1, Fig. 2). A percentage of correctly determined directions was established, for workplace conditions (Fig. 4) and after reducing the ambient noise (Fig. 5). Recognition of the direction from which the sound is coming is the most difficult when the truck is directly behind the person (20% of correct answers) and in front of the person (up to 30% of correct answers). Correct recognition of the direction is much easier (80–98% of the cases), when the sound originates from the side. Lowering the ambient noise level resulted in better recognition of the direction from which sounds played in the front of the person came.
PL
Opracowanie dotyczy zastosowania programowania liniowego całkowitoliczbowego w optymalizacji wielokryterialnej. Celem badań było opracowanie modelu sterownika decyzyjnego umożliwiającego jednoczesną minimalizację poziomu zapasów półfabrykatów wygenerowanych w procesie cięcia, jak i odpadów po rozkroju. Zadaniem sterownika było dobranie odpowiedniego programu rozkroju z uwzględnieniem zamówień produkcyjnych, bieżących zapasów półfabrykatów i ograniczeń odnośnie dopuszczalnych poziomów zapasów.
EN
This paper concerns the use of integer linear programming in a multi-criteria optimization. The aim of the research was to develop a model of the decision support system allowing simultaneous minimization of the intermediate products stocks level and waste generated in the process of cutting. The goal of controller was to select the appropriate cutting program, including production orders, the current inventory and limits on permissible stocks levels.
EN
Standardised measurements of sound attenuation of hearing protectors are performed in the frequency range from 125 Hz to 8 kHz. However, noise present at many workplaces contains significant components at higher audible frequency. Therefore, the knowledge about noise attenuation with earmuffs in the audible frequency range above 8 kHz is also necessary for proper hearing protection. The aim of this study was to obtain values of the noise attenuation with 27 commonly-used earmuffs models in the 1/3 octave bands of 10, 12.5 and 16 kHz. The measurements were conducted with a real ear at threshold (REAT) method with participation of subjects. The study showed that attenuation of earmuffs ranged from 24.7 to 42.8 dB, depending on model of earmuffs and frequency band. Furthermore, the measurements were performed with the use of acoustic test fixture which is designed especially for testing hearing protectors. Results obtained with the use of acoustic test fixture indicated that this measurement method can lead to values close to attenuation measured with participation of subjects. On the other hand, values obtained with the use of acoustic test fixture may differ average up to 14 dB from REAT method.
PL
W artykule przedstawiono. efektywny rozwój transportu, który jest jednym ze wskaźników rozwoju kraju. Analizując liczbę nowo zarejestrowanych pojazdów możemy oszacować zarówno stan rozwoju transportu jak i przewidywania przewoźników odnośnie rozwoju kraju. Na podstawie danych dotyczących nowo zarejestrowanych ciągników siodłowych i pojazdów ciężarowych z okresu 2011 do 2 kwartału 2016 oszacowano trendy liniowe dla każdego z szesnastu województw. Nierównomierny rozwój transportu w poszczególnych województwach może być spowodowany czynnikami ekonomicznymi związanymi z rozwojem regionów oraz lokalizacją firm leasingowych.
EN
The article presents the effectiveness development of transport, which is one of the indicators of development of the country. Analyzing the number of newly registered vehicles, we can estimate both the state of development of transport and the forecasting of carriers regarding the development of the country. Based on data on newly registered trucks from the period 2011 to Q2 2016 it was estimated the linear trends for each of the sixteen provinces. The non-uniform development of transport in the individual provinces may be caused by economic factors associated with the development of regions and the locations of leasing companies.
PL
W artykule przedstawiono przepisy dotyczące kierowców zawodowych, sposobu pracy, systemów bezpieczeństwa, czasu prowadzenia i czasu odpoczynku kierowcy. Badania ankietowe przeprowadzono na grupie kierowców samochodów ciężarowych oraz kierowców autobusów będących w innym wieku, mających różny staż pracy w zawodzie kierowcy oraz wykonujących przewozy krajowe i międzynarodowe. Badania zostały przeprowadzone w śród kierowców pojazdów użytkowych, które dotyczyły respektowania norm czasu pracy kierowcy w codziennej praktyce.
EN
The article presents the provisions relating to professional drivers, how to work, the safety systems, the driving time and the rest time. The surveys conducted on a group of truck drivers and bus drivers being in a different age, with different seniority in the profession of the driver and performing the domestic and international transportation. The study was conducted among drivers of vehicles, which concerned the respect of standards of drivers' hours in daily practice.
PL
Przeprowadzone badania miały na celu określenie jak jednoczesne stosowanie nauszników przeciwhałasowych i okularów korekcyjnych wpływa na zmianę tłumienia nauszników. Badania zostały przeprowadzone z wykorzystaniem metody MIRE i obejmowały wyznaczenie zmian tłumienia dźwięku pięciu modeli nauszników przeciwhałasowych stosowanych jednocześnie z trzema rodzajami okularów korekcyjnych. Przeprowadzone badania wykazały, że jednoczesne używanie okularów korekcyjnych z nausznikami obniża tłumienie nauszników w zakresie niskich i wysokich częstotliwości nawet o 16-18 dB. Tak duże zmiany występowały podczas jednoczesnego stosowania nauszników i okularów charakteryzujących się szerokimi zausznikami. Badania także wykazały zbliżony wpływ okularów na tłumienie w przypadku trzech modeli nauszników zbudowanych z tego samego rodzaju czasz tłumiących, a różniących się jedynie konstrukcją sprężyn dociskowych. Dla pozostałych dwóch modeli nauszników, wpływ okularów był bardziej zróżnicowany. Świadczy to o tym, że to głównie konstrukcja poduszki uszczelniającej ma wpływ na większą lub mniejszą zmianę tłumienia dźwięku nauszników stosowanych jednocześnie z okularami korekcyjnymi.
EN
The aim of the study was to determine how the simultaneous use of earmuffs and corrective eye glasses affects the attenuation of earmuffs. The study was performed using MIRE methods and included determination of changes in sound attenuation of five types of earmuffs used simultaneously with three types of glasses. The study showed that the simultaneous use of corrective eye glasses and earmuffs decrease the attenuation of earmuffs up to 16-18 dB in low and high frequency ranges. Such large changes have occurred during use of glasses characterized by wide temples. The study also showed a similar effect of simultaneous use of earmuffs and glasses on attenuation of earmuffs consists of the same kind of cup but differ in design of headband. For the remaining two models of earmuffs, the effect of using glasses was more diverse. This shows that the main factor influencing the decrease in sound attenuation of earmuffs is the type of sealing cushion.
PL
Celem niniejszej pracy było uzyskanie danych o tłumieniu dźwięku pięciu modeli powszechnie stosowanych nauszników przeciwhałasowych, w zakresie częstotliwości słyszalnych powyżej 8 kHz, czyli częstotliwości, które nie są standardowo rozpatrywane podczas badań ochronników słuchu. Dane takie mogą być wykorzystywane do oceny czy określony ochronnik słuchu w odpowiednim stopniu zabezpiecza słuch pracownika w pasmach tercjowych 10, 12,5 i 16 kHz. Badania przeprowadzono z użyciem dwóch metod badawczych: subiektywnej (z udziałem osób, polegającej na pomiarze progu słyszenia) oraz obiektywnej (z użyciem testera akustycznego). Tłumienie dźwięku zmierzone z udziałem osób w pasmach tercjowych z zakresu od 10 do 16 kHz, w zależności od modelu nauszników przeciwhałasowych przyjmuje wartości od 29 do 44 dB. Metoda obiektywna w większości przypadków daje wyniki zbliżone do wyników uzyskanych metodą subiektywną.
EN
The aim of this study was to obtain values of the sound attenuation with five commonly-usedearmuff models in the audible frequency range above 8 kHz, i.e. frequencies that are not usually considered during testing of hearing protection devices. Such data can be used to assess whether a specific hearing protector sufficiently protects employee hearing in one-third octave bands of 10, 12.5 and 16 kHz. Studies were conducted using two test methods: subjective (with the participation of subjects, involving the measurement of the threshold of hearing) and objective (using artificial test fixture). Sound attenuation measured with the participation of subjects in the one-third octave frequency bands ranging from 10 to 16 kHz, depending on the model of earmuffs ranges from 29 to 44 dB. Objective method, in most cases, gives a close approximation to the results obtained by subjective method.
EN
Sustaining high operational efficiency of a machine park requires the use of state-of-art solutions that support both monitoring of residual processes and performing thorough analysis of thereby collected data. What meets the needs of entrepreneurs who strive for high reliability of technological infrastructure is a modern approach to maintenance prediction. The literature of the subject offers numerous studies presenting the use of various statistical models for time series prediction. The objective of this paper is to verify whether tests used in econometrics such as the augmented Dickey-Fuller test and the Kwiatkowski-Phillips-Schmidt-Shin test are suitable for failure prediction. The simulations were performed for one diagnostic parameter, i.e. temperature.
PL
Utrzymanie wysokiego poziomu efektywności eksploatacyjnej parku maszynowego wymaga stosowania nowoczesnych rozwiązań wspierających monitorowanie procesów resztkowych i poddawania szczegółowej analizie uzyskanych w ten sposób informacji. Naprzeciw oczekiwaniom przedsiębiorców dotyczących utrzymywania wysokiego poziomu niezawodności infrastruktury technicznej wychodzi nowoczesne podejście w obszarze gospodarki remontowo-konserwacyjnej, jakim jest predyktywne utrzymanie ruchu. W literaturze przedmiotu wielokrotnie prezentowano wykorzystanie różnych modeli statystycznych pozwalających na prognozowanie wartości szeregów czasowych. Celem niniejszej pracy było sprawdzenie czy stosowany w ekonometrii rozszerzony test Dickeya-Fullera oraz test Kwiatkowskiego, Phillipsa, Schmidta i Shina mogą zostać użyte do predykcji zdarzeń niepożądanych jakimi są awarie. Symulację przeprowadzono dla wartości jednego parametru diagnostycznego jakim była temperatura.
18
Content available Tłumienie dźwięku hełmofonu czołgisty
PL
Załoga pojazdu bojowego, która jest narażona na hałas związany z pracą silnika, jak i z wystrzałami z broni palnej, ma na swoim wyposażeniu hełmofony. W artykule przedstawiono wyniki badań ograniczania hałasu przez hełmofon HC-98 w przypadku hałasu ustalonego oraz impulsowego. Stosowano dwie metody badań: pomiary tłumienia dźwięku z udziałem osób oraz pomiary tłumienia przenoszenia impulsów akustycznych przeprowadzane z użyciem testera akustycznego - urządzenia odwzorowującego głowę. Dane dla hełmofonu porównano ze skutecznością ograniczania hałasu przez dwa różne, powszechnie stosowane nauszniki przeciwhałasowe (jeden słabo, drugi silnie ograniczający hałas). Wyniki wskazały, że hełmofon spełnia wymagania, które pozwalają traktować go jako ochronnik słuchu, jednak nie zapewnia on ochrony słuchu takiej jak nauszniki przeciwhałasowe. Otrzymano stosunkowo niskie wartości tłumienia impulsów akustycznych przez badany hełmofon względem wyników dla nauszników przeciwhałasowych. Ponadto, w przypadku hełmofonu, w zakresie częstotliwości 63-2000 Hz, uzyskano niższe od około 2 do nawet 19 dB wartości tłumienia hałasu ustalonego w porównaniu z wartościami tłumienia nauszników.
EN
Crew of military vehicles, which is exposed to the noise associated with the engine running, as well as to shots from firearms, is equipped with headphones. The article presents the results of noise reduction by HC-98 headphone for steady state and impulsive noise. Two methods of research were used: sound attenuation measurements with participation of subjects and transmission loss measurements with the use of acoustic test fixture - device reflecting the properties of the head. Data for headphone were compared with noise reduction of two different, commonly used earmuffs (one light, the other strong limiting noise). The results indicated that measured headphone meets the requirements that allow for treating it as hearing protection, however, this headphone does not provide hearing protection such as earmuffs. Relatively low values of attenuation of acoustic impulses through the headphone versus the results for earmuffs were observed. Furthermore, in the case of headphone, in the frequency range 63-2000 Hz, the lower values of steady state noise sound attenuation, from about 2 up to even a 19 dB with respect to the attenuation of ear muffs were measured.
EN
The traditional production planning model based upon a deterministic approach is well described in the literature. Due to the uncertain nature of manufacturing processes, such model can however incorrectly represent actual situations on the shop floor. This study develops a mathematical modeling framework for generating production plans in a multistage manufacturing process. The devised model takes into account the stochastic model for predicting the occurrence of faulty products. The aim of the control model is to determine the number of products which should be manufactured in each planning period to minimize both manufacturing costs and potential financial penalties for failing to fulfill the order completely.
PL
Hałas impulsowy wytwarzany podczas strzałów z broni palnej charakteryzuje się znacznie większymi wartościami szczytowego poziomu dźwięku C niż ma to miejsce w przypadku impulsów wytwarzanych w przemyśle np. podczas obróbki metalu. W zależności od rodzaju broni, wystrzałom towarzyszą impulsy o poziomie 160 - 177 dB, lub nawet wyższym. Należy przy tym zaznaczyć, że hałas impulsowy obecny podczas wystrzałów z broni palnej jest szczególnie niebezpieczny i w skrajnych przypadkach trwały ubytek słuchu może być wywołany nawet pojedynczym impulsem. Szczególnego znaczenia nabiera więc ocena narażenia na ten rodzaj hałasu i skuteczność jego ograniczania przez ochronniki słuchu. Wśród kryteriów oceny narażenia na hałas wyróżnić trzeba przepisy odnoszące się do stanowisk pracy i wojskowe kryteria ryzyka uszkodzenia słuchu. Proces oceny narażenia wiąże się z określonymi trudnościami pomiarowymi, takimi jak niedostateczny zakres pomiarowy standardowych mierników poziomu dźwięku i wynikająca z tego konieczność stosowania specjalizowanego systemu pomiarowego. Ochrona słuchu napotyka natomiast na problem braku kompatybilności używanego przez żołnierzy wyposażenia: np. hełmów i nauszników przeciwhałasowych.
EN
Impulsive noise produced by firearms is characterized by a much higher values of the C-weighted peak sound pressure level than in the case of impulses produced in the industry e.g. during metalworking processes. Depending on the type of weapons, shootings are associated with impulses which level is 160 - 177 dB or even higher. It should be noted that the impulse noise present during the firing of firearms is particularly hazardous and in extreme cases, permanent hearing loss can be caused by even a single impulse. Of particular importance is assessment of exposure to this kind of noise and the effectiveness of its limiting by hearing protectors. Among the criteria for the assessment of exposure to noise it should be listed regulations applied to workstations and hearing damage risk criteria developed for the Army. The process of assessment of exposure is associated with certain difficulties in measurements, such as insufficient range of standard sound level meters and consequently need for using specialized measurement system. Hearing conservation while encountering the problem of the lack of compatibility of equipment used by the soldiers, e.g. helmets and earmuffs.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.